Cargando…

Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication

pCONus is a stent like endovascular device which aids in retention of coils within wide necked bifurcation aneurysms. It is retrievable even after complete deployment and is detached electrolytically. pCONus aided coiling of wide necked bifurcation aneurysms has a high technical success rate and a g...

Descripción completa

Detalles Bibliográficos
Autores principales: Premnath, Krishna Prasad Bellam, Kuruttukulam, Gigy, Shivan, Anil Kumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747212/
https://www.ncbi.nlm.nih.gov/pubmed/29296469
http://dx.doi.org/10.4103/jcis.JCIS_67_17
_version_ 1783289246097866752
author Premnath, Krishna Prasad Bellam
Kuruttukulam, Gigy
Shivan, Anil Kumar
author_facet Premnath, Krishna Prasad Bellam
Kuruttukulam, Gigy
Shivan, Anil Kumar
author_sort Premnath, Krishna Prasad Bellam
collection PubMed
description pCONus is a stent like endovascular device which aids in retention of coils within wide necked bifurcation aneurysms. It is retrievable even after complete deployment and is detached electrolytically. pCONus aided coiling of wide necked bifurcation aneurysms has a high technical success rate and a good safety profile. Different complications have been described in literature with the usage of pCONus. This case report describes a yet unreported complication of un-re-sheath-ability of a misaligned deployed pCONus device.
format Online
Article
Text
id pubmed-5747212
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-57472122018-01-02 Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication Premnath, Krishna Prasad Bellam Kuruttukulam, Gigy Shivan, Anil Kumar J Clin Imaging Sci Case Report pCONus is a stent like endovascular device which aids in retention of coils within wide necked bifurcation aneurysms. It is retrievable even after complete deployment and is detached electrolytically. pCONus aided coiling of wide necked bifurcation aneurysms has a high technical success rate and a good safety profile. Different complications have been described in literature with the usage of pCONus. This case report describes a yet unreported complication of un-re-sheath-ability of a misaligned deployed pCONus device. Medknow Publications & Media Pvt Ltd 2017-10-30 /pmc/articles/PMC5747212/ /pubmed/29296469 http://dx.doi.org/10.4103/jcis.JCIS_67_17 Text en Copyright: © 2017 Journal of Clinical Imaging Science http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Case Report
Premnath, Krishna Prasad Bellam
Kuruttukulam, Gigy
Shivan, Anil Kumar
Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication
title Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication
title_full Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication
title_fullStr Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication
title_full_unstemmed Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication
title_short Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication
title_sort un-re-sheath-able misaligned pconus device: case report of a unique complication
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747212/
https://www.ncbi.nlm.nih.gov/pubmed/29296469
http://dx.doi.org/10.4103/jcis.JCIS_67_17
work_keys_str_mv AT premnathkrishnaprasadbellam unresheathablemisalignedpconusdevicecasereportofauniquecomplication
AT kuruttukulamgigy unresheathablemisalignedpconusdevicecasereportofauniquecomplication
AT shivananilkumar unresheathablemisalignedpconusdevicecasereportofauniquecomplication