Cargando…

A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver

INTRODUCTION: The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a ”key” instrument to accomplish this arduous task. INSTRUMENT: The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any...

Descripción completa

Detalles Bibliográficos
Autores principales: Ganpule, Arvind P., Deshmukh, Chaitanya S., Joshi, Tanmay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5749207/
https://www.ncbi.nlm.nih.gov/pubmed/28782740
http://dx.doi.org/10.4103/jmas.JMAS_191_16
_version_ 1783289550568685568
author Ganpule, Arvind P.
Deshmukh, Chaitanya S.
Joshi, Tanmay
author_facet Ganpule, Arvind P.
Deshmukh, Chaitanya S.
Joshi, Tanmay
author_sort Ganpule, Arvind P.
collection PubMed
description INTRODUCTION: The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a ”key” instrument to accomplish this arduous task. INSTRUMENT: The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. VALIDATION: We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. CONCLUSION: The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.
format Online
Article
Text
id pubmed-5749207
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-57492072018-01-04 A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver Ganpule, Arvind P. Deshmukh, Chaitanya S. Joshi, Tanmay J Minim Access Surg Instruments and Equipments INTRODUCTION: The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a ”key” instrument to accomplish this arduous task. INSTRUMENT: The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. VALIDATION: We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. CONCLUSION: The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5749207/ /pubmed/28782740 http://dx.doi.org/10.4103/jmas.JMAS_191_16 Text en Copyright: © 2017 Journal of Minimal Access Surgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Instruments and Equipments
Ganpule, Arvind P.
Deshmukh, Chaitanya S.
Joshi, Tanmay
A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver
title A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver
title_full A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver
title_fullStr A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver
title_full_unstemmed A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver
title_short A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver
title_sort novel prototype 3/5 laparoscopic needle driver: a validation study with conventional laparoscopic needle driver
topic Instruments and Equipments
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5749207/
https://www.ncbi.nlm.nih.gov/pubmed/28782740
http://dx.doi.org/10.4103/jmas.JMAS_191_16
work_keys_str_mv AT ganpulearvindp anovelprototype35laparoscopicneedledriveravalidationstudywithconventionallaparoscopicneedledriver
AT deshmukhchaitanyas anovelprototype35laparoscopicneedledriveravalidationstudywithconventionallaparoscopicneedledriver
AT joshitanmay anovelprototype35laparoscopicneedledriveravalidationstudywithconventionallaparoscopicneedledriver
AT ganpulearvindp novelprototype35laparoscopicneedledriveravalidationstudywithconventionallaparoscopicneedledriver
AT deshmukhchaitanyas novelprototype35laparoscopicneedledriveravalidationstudywithconventionallaparoscopicneedledriver
AT joshitanmay novelprototype35laparoscopicneedledriveravalidationstudywithconventionallaparoscopicneedledriver