In vivo investigation of ear canal pulse oximetry during hypothermia

Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial oxygen saturation (SpO[Formula: see text] ). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often weak and noisy, or in some cases...

Descripción completa

Detalles Bibliográficos
Autores principales: Budidha, K, Kyriacou, P A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750340/
https://www.ncbi.nlm.nih.gov/pubmed/28130679
http://dx.doi.org/10.1007/s10877-017-9975-4
_version_ 1783289701059264512
author Budidha, K
Kyriacou, P A
author_facet Budidha, K
Kyriacou, P A
author_sort Budidha, K
collection PubMed
description Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial oxygen saturation (SpO[Formula: see text] ). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often weak and noisy, or in some cases unobtainable. Hence, pulse oximeters produce erroneous SpO[Formula: see text] readings in these circumstances. The problem arises as most commercial pulse oximeter probes are designed to be attached to peripheral sites such as the finger or toe, which are easily affected by vasoconstriction. In order to overcome this problem, the ear canal was investigated as an alternative site for measuring reliable SpO[Formula: see text] on the hypothesis that blood flow to this central site is preferentially preserved. A novel miniature ear canal PPG sensor was developed along with a state of the art PPG processing unit to investigate PPG measurements from the bottom surface of the ear canal. An in vivo study was carried out in 15 healthy volunteers to validate the developed technology. In this comparative study, red and infrared PPGs were acquired from the ear canal and the finger of the volunteers, whilst they were undergoing artificially induced hypothermia by means of cold exposure (10 [Formula: see text] C). Normalised Pulse Amplitude (NPA) and SpO[Formula: see text] was calculated from the PPG signals acquired from the ear canal and the finger. Good quality baseline PPG signals with high signal-to-noise ratio were obtained from both the PPG sensors. During cold exposure, significant differences were observed in the NPA of the finger PPGs. The mean NPA of the red and infrared PPGs from the finger have dropped by >80%. Contrary to the finger, the mean NPA of red and infrared ear canal PPGs had dropped only by 0.2 and 13% respectively. The SpO[Formula: see text] s estimated from the finger sensor have dropped below 90% in five volunteers (failure) by the end of the cold exposure. The ear canal sensor, on the other hand, had only failed in one volunteer. These results strongly suggest that the ear canal may be used as a suitable alternative site for monitoring PPGs and arterial blood oxygen saturation at times were peripheral perfusion is compromised.
format Online
Article
Text
id pubmed-5750340
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-57503402018-01-22 In vivo investigation of ear canal pulse oximetry during hypothermia Budidha, K Kyriacou, P A J Clin Monit Comput Original Research Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial oxygen saturation (SpO[Formula: see text] ). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often weak and noisy, or in some cases unobtainable. Hence, pulse oximeters produce erroneous SpO[Formula: see text] readings in these circumstances. The problem arises as most commercial pulse oximeter probes are designed to be attached to peripheral sites such as the finger or toe, which are easily affected by vasoconstriction. In order to overcome this problem, the ear canal was investigated as an alternative site for measuring reliable SpO[Formula: see text] on the hypothesis that blood flow to this central site is preferentially preserved. A novel miniature ear canal PPG sensor was developed along with a state of the art PPG processing unit to investigate PPG measurements from the bottom surface of the ear canal. An in vivo study was carried out in 15 healthy volunteers to validate the developed technology. In this comparative study, red and infrared PPGs were acquired from the ear canal and the finger of the volunteers, whilst they were undergoing artificially induced hypothermia by means of cold exposure (10 [Formula: see text] C). Normalised Pulse Amplitude (NPA) and SpO[Formula: see text] was calculated from the PPG signals acquired from the ear canal and the finger. Good quality baseline PPG signals with high signal-to-noise ratio were obtained from both the PPG sensors. During cold exposure, significant differences were observed in the NPA of the finger PPGs. The mean NPA of the red and infrared PPGs from the finger have dropped by >80%. Contrary to the finger, the mean NPA of red and infrared ear canal PPGs had dropped only by 0.2 and 13% respectively. The SpO[Formula: see text] s estimated from the finger sensor have dropped below 90% in five volunteers (failure) by the end of the cold exposure. The ear canal sensor, on the other hand, had only failed in one volunteer. These results strongly suggest that the ear canal may be used as a suitable alternative site for monitoring PPGs and arterial blood oxygen saturation at times were peripheral perfusion is compromised. Springer Netherlands 2017-01-27 2018 /pmc/articles/PMC5750340/ /pubmed/28130679 http://dx.doi.org/10.1007/s10877-017-9975-4 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Budidha, K
Kyriacou, P A
In vivo investigation of ear canal pulse oximetry during hypothermia
title In vivo investigation of ear canal pulse oximetry during hypothermia
title_full In vivo investigation of ear canal pulse oximetry during hypothermia
title_fullStr In vivo investigation of ear canal pulse oximetry during hypothermia
title_full_unstemmed In vivo investigation of ear canal pulse oximetry during hypothermia
title_short In vivo investigation of ear canal pulse oximetry during hypothermia
title_sort in vivo investigation of ear canal pulse oximetry during hypothermia
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750340/
https://www.ncbi.nlm.nih.gov/pubmed/28130679
http://dx.doi.org/10.1007/s10877-017-9975-4
work_keys_str_mv AT budidhak invivoinvestigationofearcanalpulseoximetryduringhypothermia
AT kyriacoupa invivoinvestigationofearcanalpulseoximetryduringhypothermia