Cargando…

A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring

In this paper, a novel approach for concrete chloride ion concentration measuring based on passive and wireless sensor tag is proposed. The chloride ion sensor based on RFID communication protocol is consisting of an energy harvesting and management circuit, a low dropout voltage regulator, a MCU, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Shuangxi, Sheng, Wei, Deng, Fangming, Wu, Xiang, Fu, Zhihui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750668/
https://www.ncbi.nlm.nih.gov/pubmed/29232901
http://dx.doi.org/10.3390/s17122871
_version_ 1783289773828341760
author Zhou, Shuangxi
Sheng, Wei
Deng, Fangming
Wu, Xiang
Fu, Zhihui
author_facet Zhou, Shuangxi
Sheng, Wei
Deng, Fangming
Wu, Xiang
Fu, Zhihui
author_sort Zhou, Shuangxi
collection PubMed
description In this paper, a novel approach for concrete chloride ion concentration measuring based on passive and wireless sensor tag is proposed. The chloride ion sensor based on RFID communication protocol is consisting of an energy harvesting and management circuit, a low dropout voltage regulator, a MCU, a RFID tag chip and a pair of electrodes. The proposed sensor harvests energy radiated by the RFID reader to power its circuitry. To improve the stability of power supply, a three-stage boost rectifier is customized to rectify the harvested power into dc power and step-up the voltage. Since the measured data is wirelessly transmitted, it contains miscellaneous noises which would decrease the accuracy of measuring. Thus, in this paper, the wavelet denoising method is adopted to denoise the raw data. Besides, a monitoring software is developed to display the measurement results in real-time. The measurement results indicate that the proposed passive sensor tag can achieve a reliable communication distance of 16.3 m and can reliably measure the chloride ion concentration in concrete.
format Online
Article
Text
id pubmed-5750668
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57506682018-01-10 A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring Zhou, Shuangxi Sheng, Wei Deng, Fangming Wu, Xiang Fu, Zhihui Sensors (Basel) Article In this paper, a novel approach for concrete chloride ion concentration measuring based on passive and wireless sensor tag is proposed. The chloride ion sensor based on RFID communication protocol is consisting of an energy harvesting and management circuit, a low dropout voltage regulator, a MCU, a RFID tag chip and a pair of electrodes. The proposed sensor harvests energy radiated by the RFID reader to power its circuitry. To improve the stability of power supply, a three-stage boost rectifier is customized to rectify the harvested power into dc power and step-up the voltage. Since the measured data is wirelessly transmitted, it contains miscellaneous noises which would decrease the accuracy of measuring. Thus, in this paper, the wavelet denoising method is adopted to denoise the raw data. Besides, a monitoring software is developed to display the measurement results in real-time. The measurement results indicate that the proposed passive sensor tag can achieve a reliable communication distance of 16.3 m and can reliably measure the chloride ion concentration in concrete. MDPI 2017-12-11 /pmc/articles/PMC5750668/ /pubmed/29232901 http://dx.doi.org/10.3390/s17122871 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhou, Shuangxi
Sheng, Wei
Deng, Fangming
Wu, Xiang
Fu, Zhihui
A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring
title A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring
title_full A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring
title_fullStr A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring
title_full_unstemmed A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring
title_short A Novel Passive Wireless Sensing Method for Concrete Chloride Ion Concentration Monitoring
title_sort novel passive wireless sensing method for concrete chloride ion concentration monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750668/
https://www.ncbi.nlm.nih.gov/pubmed/29232901
http://dx.doi.org/10.3390/s17122871
work_keys_str_mv AT zhoushuangxi anovelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT shengwei anovelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT dengfangming anovelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT wuxiang anovelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT fuzhihui anovelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT zhoushuangxi novelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT shengwei novelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT dengfangming novelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT wuxiang novelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring
AT fuzhihui novelpassivewirelesssensingmethodforconcretechlorideionconcentrationmonitoring