Cargando…

Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates

BACKGROUND: Nowadays, digital radiography is widely used in dental practice. One of the most common types is Photo Stimulated Phosphor Plate (PSP). OBJECTIVE: The aims of this experimental study were to evaluate the impacts of different combinations of storage conditions and varying delays in readin...

Descripción completa

Detalles Bibliográficos
Autores principales: Eskandarloo, Amir, Yousefi, Arman, Soheili, Setareh, Ghazikhanloo, Karim, Amini, Payam, Mohammadpoor, Haniyeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750681/
https://www.ncbi.nlm.nih.gov/pubmed/29430262
http://dx.doi.org/10.2174/1874210601711010690
_version_ 1783289776871309312
author Eskandarloo, Amir
Yousefi, Arman
Soheili, Setareh
Ghazikhanloo, Karim
Amini, Payam
Mohammadpoor, Haniyeh
author_facet Eskandarloo, Amir
Yousefi, Arman
Soheili, Setareh
Ghazikhanloo, Karim
Amini, Payam
Mohammadpoor, Haniyeh
author_sort Eskandarloo, Amir
collection PubMed
description BACKGROUND: Nowadays, digital radiography is widely used in dental practice. One of the most common types is Photo Stimulated Phosphor Plate (PSP). OBJECTIVE: The aims of this experimental study were to evaluate the impacts of different combinations of storage conditions and varying delays in reading of digital images captured using PSPs. METHODS: Standardized images of a step wedges were obtained using PSPs from the Digora digital systems. Plates were exposed and immediately scanned to produce the baseline gold standard. The plates were re-exposed and stored in four different storage conditions: white light, yellow light, natural light environment and dark room, then scanned after 10 and 30 minutes and 4 and 8 hours. Objective analysis was conducted by density measurements and the data were analyzed statistically using GEE test. Subjective analysis was performed by two oral and maxillofacial radiologists and the results were analyzed using McNemar’s test. RESULTS: The results from GEE analysis show that in the natural light environment, the densities in 10 minutes did not differ from the baseline. The mean densities decreased significantly during the time in all environments. The mean densities in step 2 for the dark room environment decreased with a slighter slope in comparison to yellow environment significantly. CONCLUSION: PSP images showed significant decrease in the density in plates scanned for 10 minutes or longer after exposure which may not be detected clinically. The yellow light environment had a different impact on the quality of PSP images. The spatial resolution did not change significantly with time.
format Online
Article
Text
id pubmed-5750681
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-57506812018-02-09 Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates Eskandarloo, Amir Yousefi, Arman Soheili, Setareh Ghazikhanloo, Karim Amini, Payam Mohammadpoor, Haniyeh Open Dent J Todentj BACKGROUND: Nowadays, digital radiography is widely used in dental practice. One of the most common types is Photo Stimulated Phosphor Plate (PSP). OBJECTIVE: The aims of this experimental study were to evaluate the impacts of different combinations of storage conditions and varying delays in reading of digital images captured using PSPs. METHODS: Standardized images of a step wedges were obtained using PSPs from the Digora digital systems. Plates were exposed and immediately scanned to produce the baseline gold standard. The plates were re-exposed and stored in four different storage conditions: white light, yellow light, natural light environment and dark room, then scanned after 10 and 30 minutes and 4 and 8 hours. Objective analysis was conducted by density measurements and the data were analyzed statistically using GEE test. Subjective analysis was performed by two oral and maxillofacial radiologists and the results were analyzed using McNemar’s test. RESULTS: The results from GEE analysis show that in the natural light environment, the densities in 10 minutes did not differ from the baseline. The mean densities decreased significantly during the time in all environments. The mean densities in step 2 for the dark room environment decreased with a slighter slope in comparison to yellow environment significantly. CONCLUSION: PSP images showed significant decrease in the density in plates scanned for 10 minutes or longer after exposure which may not be detected clinically. The yellow light environment had a different impact on the quality of PSP images. The spatial resolution did not change significantly with time. Bentham Open 2017-12-29 /pmc/articles/PMC5750681/ /pubmed/29430262 http://dx.doi.org/10.2174/1874210601711010690 Text en © 2017 Eskandarloo et al. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Todentj
Eskandarloo, Amir
Yousefi, Arman
Soheili, Setareh
Ghazikhanloo, Karim
Amini, Payam
Mohammadpoor, Haniyeh
Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates
title Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates
title_full Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates
title_fullStr Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates
title_full_unstemmed Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates
title_short Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates
title_sort evaluation of the effect of light and scanning time delay on the image quality of intra oral photostimulable phosphor plates
topic Todentj
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750681/
https://www.ncbi.nlm.nih.gov/pubmed/29430262
http://dx.doi.org/10.2174/1874210601711010690
work_keys_str_mv AT eskandarlooamir evaluationoftheeffectoflightandscanningtimedelayontheimagequalityofintraoralphotostimulablephosphorplates
AT yousefiarman evaluationoftheeffectoflightandscanningtimedelayontheimagequalityofintraoralphotostimulablephosphorplates
AT soheilisetareh evaluationoftheeffectoflightandscanningtimedelayontheimagequalityofintraoralphotostimulablephosphorplates
AT ghazikhanlookarim evaluationoftheeffectoflightandscanningtimedelayontheimagequalityofintraoralphotostimulablephosphorplates
AT aminipayam evaluationoftheeffectoflightandscanningtimedelayontheimagequalityofintraoralphotostimulablephosphorplates
AT mohammadpoorhaniyeh evaluationoftheeffectoflightandscanningtimedelayontheimagequalityofintraoralphotostimulablephosphorplates