Cargando…
Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure
BACKGROUND: The sensitivity of peripheral chemoreflex is a marker of the severity of heart failure and the prognosis of the outcome in these patients. The assessment of chemosensitivity in these patients remains an actual problem. OBJECTIVE: The aim of the study was to explore the relationship betwe...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750724/ https://www.ncbi.nlm.nih.gov/pubmed/29387285 http://dx.doi.org/10.2174/1874306401711010067 |
_version_ | 1783289786678640640 |
---|---|
author | Trembach, Nikita Zabolotskikh, Igor |
author_facet | Trembach, Nikita Zabolotskikh, Igor |
author_sort | Trembach, Nikita |
collection | PubMed |
description | BACKGROUND: The sensitivity of peripheral chemoreflex is a marker of the severity of heart failure and the prognosis of the outcome in these patients. The assessment of chemosensitivity in these patients remains an actual problem. OBJECTIVE: The aim of the study was to explore the relationship between a Breath-Holding Test (BHT) and single-breath carbon dioxide test and to evaluate the reliability of both tests in patients with Heart Failure (HF). METHOD: The study was performed in 43 patients with chronic heart failure. All subjects underwent BHT and single-breath carbon dioxide (CB-CO(2)), the evaluation of both tests was repeated a month later. Relationship of two test was evaluated by correlation analysis. Reliability was assessed with calculation of Standard Error of Measurement (SEM), Coefficient of Variation (CV) and Intraclass Correlation Coefficient (ICC). RESULTS: The duration of the breath-holding was inversely correlated to the result of CB-CO(2) test (r = -0.86 at first measurement and r = -0.79 after a month) The ICC was 0.87 (95%CI: 0.78–0.93) for SB-CO(2) test and 0,93 (95%CI: 0.88–0.96) for BHT, the CV was 24% for SB-CO(2) and 13% for BHT. SEM for SB-CO(2) test was 0.04 L / min / mmHg and limits of variation was 0.11 L / min / mmHg; SEM for BHT was 3.6 sec and limits of variation was10 sec. CONCLUSION: Breath-holding test is a reliable and safe method for assessing the sensitivity of peripheral chemoreflex to carbon dioxide in patients with heart failure. |
format | Online Article Text |
id | pubmed-5750724 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-57507242018-01-31 Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure Trembach, Nikita Zabolotskikh, Igor Open Respir Med J Article BACKGROUND: The sensitivity of peripheral chemoreflex is a marker of the severity of heart failure and the prognosis of the outcome in these patients. The assessment of chemosensitivity in these patients remains an actual problem. OBJECTIVE: The aim of the study was to explore the relationship between a Breath-Holding Test (BHT) and single-breath carbon dioxide test and to evaluate the reliability of both tests in patients with Heart Failure (HF). METHOD: The study was performed in 43 patients with chronic heart failure. All subjects underwent BHT and single-breath carbon dioxide (CB-CO(2)), the evaluation of both tests was repeated a month later. Relationship of two test was evaluated by correlation analysis. Reliability was assessed with calculation of Standard Error of Measurement (SEM), Coefficient of Variation (CV) and Intraclass Correlation Coefficient (ICC). RESULTS: The duration of the breath-holding was inversely correlated to the result of CB-CO(2) test (r = -0.86 at first measurement and r = -0.79 after a month) The ICC was 0.87 (95%CI: 0.78–0.93) for SB-CO(2) test and 0,93 (95%CI: 0.88–0.96) for BHT, the CV was 24% for SB-CO(2) and 13% for BHT. SEM for SB-CO(2) test was 0.04 L / min / mmHg and limits of variation was 0.11 L / min / mmHg; SEM for BHT was 3.6 sec and limits of variation was10 sec. CONCLUSION: Breath-holding test is a reliable and safe method for assessing the sensitivity of peripheral chemoreflex to carbon dioxide in patients with heart failure. Bentham Open 2017-12-27 /pmc/articles/PMC5750724/ /pubmed/29387285 http://dx.doi.org/10.2174/1874306401711010067 Text en © 2017 Trembach and Zabolotskikh. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Article Trembach, Nikita Zabolotskikh, Igor Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure |
title | Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure |
title_full | Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure |
title_fullStr | Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure |
title_full_unstemmed | Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure |
title_short | Evaluation of Breath-Holding Test in Assessment of Peripheral Chemoreflex Sensitivity in Patients with Chronic Heart Failure |
title_sort | evaluation of breath-holding test in assessment of peripheral chemoreflex sensitivity in patients with chronic heart failure |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750724/ https://www.ncbi.nlm.nih.gov/pubmed/29387285 http://dx.doi.org/10.2174/1874306401711010067 |
work_keys_str_mv | AT trembachnikita evaluationofbreathholdingtestinassessmentofperipheralchemoreflexsensitivityinpatientswithchronicheartfailure AT zabolotskikhigor evaluationofbreathholdingtestinassessmentofperipheralchemoreflexsensitivityinpatientswithchronicheartfailure |