Cargando…

First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range

In this work, a robust stand-off alpha detection method using the secondary effects of alpha radiation has been sought. Alpha particles ionise the surrounding atmosphere as they travel. Fluorescence photons produced as a consequence of this can be used to detect the source of the alpha emissions. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Crompton, Anita J., Gamage, Kelum A. A., Bell, Steven, Wilson, Andrew P., Jenkins, Alex, Trivedi, Divyesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750792/
https://www.ncbi.nlm.nih.gov/pubmed/29186051
http://dx.doi.org/10.3390/s17122756
_version_ 1783289803167498240
author Crompton, Anita J.
Gamage, Kelum A. A.
Bell, Steven
Wilson, Andrew P.
Jenkins, Alex
Trivedi, Divyesh
author_facet Crompton, Anita J.
Gamage, Kelum A. A.
Bell, Steven
Wilson, Andrew P.
Jenkins, Alex
Trivedi, Divyesh
author_sort Crompton, Anita J.
collection PubMed
description In this work, a robust stand-off alpha detection method using the secondary effects of alpha radiation has been sought. Alpha particles ionise the surrounding atmosphere as they travel. Fluorescence photons produced as a consequence of this can be used to detect the source of the alpha emissions. This paper details experiments carried out to detect this fluorescence, with the focus on photons in the ultraviolet C (UVC) wavelength range (180–280 nm). A detector, UVTron R9533 (Hamamatsu, 325-6, Sunayama-cho, Naka-ku, Hamamatsu City, Shizuoka Pref., 430-8587, Japan), designed to detect the UVC emissions from flames for fire alarm purposes, was tested in various gas atmospheres with a (210)Po alpha source to determine if this could provide an avenue for stand-off alpha detection. The results of the experiments show that this detector is capable of detecting alpha-induced air fluorescence in normal indoor lighting conditions, as the interference from daylight and artificial lighting is less influential on this detection system which operates below the UVA and UVB wavelength ranges (280–315 nm and 315–380 nm respectively). Assuming a standard [Formula: see text] drop off in signal, the limit of detection in this configuration can be calculated to be approximately 240 mm, well beyond the range of alpha-particles in air, which indicates that this approach could have potential for stand-off alpha detection. The gas atmospheres tested produced an increase in the detector count, with xenon having the greatest effect with a measured 52% increase in the detector response in comparison to the detector response in an air atmosphere. This type of alpha detection system could be operated at a distance, where it would potentially provide a more cost effective, safer, and faster solution in comparison with traditional alpha detection methods to detect and characterise alpha contamination in nuclear decommissioning and security applications.
format Online
Article
Text
id pubmed-5750792
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57507922018-01-10 First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range Crompton, Anita J. Gamage, Kelum A. A. Bell, Steven Wilson, Andrew P. Jenkins, Alex Trivedi, Divyesh Sensors (Basel) Article In this work, a robust stand-off alpha detection method using the secondary effects of alpha radiation has been sought. Alpha particles ionise the surrounding atmosphere as they travel. Fluorescence photons produced as a consequence of this can be used to detect the source of the alpha emissions. This paper details experiments carried out to detect this fluorescence, with the focus on photons in the ultraviolet C (UVC) wavelength range (180–280 nm). A detector, UVTron R9533 (Hamamatsu, 325-6, Sunayama-cho, Naka-ku, Hamamatsu City, Shizuoka Pref., 430-8587, Japan), designed to detect the UVC emissions from flames for fire alarm purposes, was tested in various gas atmospheres with a (210)Po alpha source to determine if this could provide an avenue for stand-off alpha detection. The results of the experiments show that this detector is capable of detecting alpha-induced air fluorescence in normal indoor lighting conditions, as the interference from daylight and artificial lighting is less influential on this detection system which operates below the UVA and UVB wavelength ranges (280–315 nm and 315–380 nm respectively). Assuming a standard [Formula: see text] drop off in signal, the limit of detection in this configuration can be calculated to be approximately 240 mm, well beyond the range of alpha-particles in air, which indicates that this approach could have potential for stand-off alpha detection. The gas atmospheres tested produced an increase in the detector count, with xenon having the greatest effect with a measured 52% increase in the detector response in comparison to the detector response in an air atmosphere. This type of alpha detection system could be operated at a distance, where it would potentially provide a more cost effective, safer, and faster solution in comparison with traditional alpha detection methods to detect and characterise alpha contamination in nuclear decommissioning and security applications. MDPI 2017-11-29 /pmc/articles/PMC5750792/ /pubmed/29186051 http://dx.doi.org/10.3390/s17122756 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Crompton, Anita J.
Gamage, Kelum A. A.
Bell, Steven
Wilson, Andrew P.
Jenkins, Alex
Trivedi, Divyesh
First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range
title First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range
title_full First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range
title_fullStr First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range
title_full_unstemmed First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range
title_short First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range
title_sort first results of using a uvtron flame sensor to detect alpha-induced air fluorescence in the uvc wavelength range
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750792/
https://www.ncbi.nlm.nih.gov/pubmed/29186051
http://dx.doi.org/10.3390/s17122756
work_keys_str_mv AT cromptonanitaj firstresultsofusingauvtronflamesensortodetectalphainducedairfluorescenceintheuvcwavelengthrange
AT gamagekelumaa firstresultsofusingauvtronflamesensortodetectalphainducedairfluorescenceintheuvcwavelengthrange
AT bellsteven firstresultsofusingauvtronflamesensortodetectalphainducedairfluorescenceintheuvcwavelengthrange
AT wilsonandrewp firstresultsofusingauvtronflamesensortodetectalphainducedairfluorescenceintheuvcwavelengthrange
AT jenkinsalex firstresultsofusingauvtronflamesensortodetectalphainducedairfluorescenceintheuvcwavelengthrange
AT trivedidivyesh firstresultsofusingauvtronflamesensortodetectalphainducedairfluorescenceintheuvcwavelengthrange