Cargando…

Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study

Humans are surrounded by sources of daily exposure to power-frequency (60 Hz in North America) magnetic fields (MFs). Such time-varying MFs induce electric fields and currents in living structures which possibly lead to biological effects. The present pilot study examined possible extremely low freq...

Descripción completa

Detalles Bibliográficos
Autores principales: Davarpanah Jazi, Shirin, Modolo, Julien, Baker, Cadence, Villard, Sebastien, Legros, Alexandre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750865/
https://www.ncbi.nlm.nih.gov/pubmed/29186760
http://dx.doi.org/10.3390/ijerph14121446
_version_ 1783289817957662720
author Davarpanah Jazi, Shirin
Modolo, Julien
Baker, Cadence
Villard, Sebastien
Legros, Alexandre
author_facet Davarpanah Jazi, Shirin
Modolo, Julien
Baker, Cadence
Villard, Sebastien
Legros, Alexandre
author_sort Davarpanah Jazi, Shirin
collection PubMed
description Humans are surrounded by sources of daily exposure to power-frequency (60 Hz in North America) magnetic fields (MFs). Such time-varying MFs induce electric fields and currents in living structures which possibly lead to biological effects. The present pilot study examined possible extremely low frequency (ELF) MF effects on human neuromotor control in general, and physiological postural tremor and electroencephalography (EEG) in particular. Since the EEG cortical mu-rhythm (8–12 Hz) from the primary motor cortex and physiological tremor are related, it was hypothesized that a 60 Hz MF exposure focused on this cortical region could acutely modulate human physiological tremor. Ten healthy volunteers (age: 23.8 ± 4 SD) were fitted with a MRI-compatible EEG cap while exposed to 11 MF conditions (60 Hz, 0 to 50 mT(rms), 5 mT(rms) increments). Simultaneously, physiological tremor (recorded from the contralateral index finger) and EEG (from associated motor and somatosensory brain regions) were measured. Results showed no significant main effect of MF exposure conditions on any of the analyzed physiological tremor characteristics. In terms of EEG, no significant effects of the MF were observed for C1, C3, C5 and CP1 electrodes. However, a significant main effect was found for CP3 and CP5 electrodes, both suggesting a decreased mu-rhythm spectral power with increasing MF flux density. This is however not confirmed by Bonferroni corrected pairwise comparisons. Considering both EEG and tremor findings, no effect of the MF exposure on human motor control was observed. However, MF exposure had a subtle effect on the mu-rhythm amplitude in the brain region involved in tactile perception. Current findings are to be considered with caution due to the small size of this pilot work, but they provide preliminary insights to international agencies establishing guidelines regarding electromagnetic field exposure with new experimental data acquired in humans exposed to high mT-range MFs.
format Online
Article
Text
id pubmed-5750865
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57508652018-01-10 Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study Davarpanah Jazi, Shirin Modolo, Julien Baker, Cadence Villard, Sebastien Legros, Alexandre Int J Environ Res Public Health Article Humans are surrounded by sources of daily exposure to power-frequency (60 Hz in North America) magnetic fields (MFs). Such time-varying MFs induce electric fields and currents in living structures which possibly lead to biological effects. The present pilot study examined possible extremely low frequency (ELF) MF effects on human neuromotor control in general, and physiological postural tremor and electroencephalography (EEG) in particular. Since the EEG cortical mu-rhythm (8–12 Hz) from the primary motor cortex and physiological tremor are related, it was hypothesized that a 60 Hz MF exposure focused on this cortical region could acutely modulate human physiological tremor. Ten healthy volunteers (age: 23.8 ± 4 SD) were fitted with a MRI-compatible EEG cap while exposed to 11 MF conditions (60 Hz, 0 to 50 mT(rms), 5 mT(rms) increments). Simultaneously, physiological tremor (recorded from the contralateral index finger) and EEG (from associated motor and somatosensory brain regions) were measured. Results showed no significant main effect of MF exposure conditions on any of the analyzed physiological tremor characteristics. In terms of EEG, no significant effects of the MF were observed for C1, C3, C5 and CP1 electrodes. However, a significant main effect was found for CP3 and CP5 electrodes, both suggesting a decreased mu-rhythm spectral power with increasing MF flux density. This is however not confirmed by Bonferroni corrected pairwise comparisons. Considering both EEG and tremor findings, no effect of the MF exposure on human motor control was observed. However, MF exposure had a subtle effect on the mu-rhythm amplitude in the brain region involved in tactile perception. Current findings are to be considered with caution due to the small size of this pilot work, but they provide preliminary insights to international agencies establishing guidelines regarding electromagnetic field exposure with new experimental data acquired in humans exposed to high mT-range MFs. MDPI 2017-11-24 2017-12 /pmc/articles/PMC5750865/ /pubmed/29186760 http://dx.doi.org/10.3390/ijerph14121446 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Davarpanah Jazi, Shirin
Modolo, Julien
Baker, Cadence
Villard, Sebastien
Legros, Alexandre
Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study
title Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study
title_full Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study
title_fullStr Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study
title_full_unstemmed Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study
title_short Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study
title_sort effects of a 60 hz magnetic field of up to 50 millitesla on human tremor and eeg: a pilot study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5750865/
https://www.ncbi.nlm.nih.gov/pubmed/29186760
http://dx.doi.org/10.3390/ijerph14121446
work_keys_str_mv AT davarpanahjazishirin effectsofa60hzmagneticfieldofupto50milliteslaonhumantremorandeegapilotstudy
AT modolojulien effectsofa60hzmagneticfieldofupto50milliteslaonhumantremorandeegapilotstudy
AT bakercadence effectsofa60hzmagneticfieldofupto50milliteslaonhumantremorandeegapilotstudy
AT villardsebastien effectsofa60hzmagneticfieldofupto50milliteslaonhumantremorandeegapilotstudy
AT legrosalexandre effectsofa60hzmagneticfieldofupto50milliteslaonhumantremorandeegapilotstudy