Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids
Screen-printed graphite electrodes (SPGEs) have been used for the first time as platforms to detect oxygen gas in room-temperature ionic liquids (RTILs). Up until now, carbon-based SPEs have shown inferior behaviour compared to platinum and gold SPEs for gas sensing with RTIL solvents. The electroch...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751384/ https://www.ncbi.nlm.nih.gov/pubmed/29186869 http://dx.doi.org/10.3390/s17122734 |
_version_ | 1783289939477135360 |
---|---|
author | Lee, Junqiao Hussain, Ghulam Banks, Craig E. Silvester, Debbie S. |
author_facet | Lee, Junqiao Hussain, Ghulam Banks, Craig E. Silvester, Debbie S. |
author_sort | Lee, Junqiao |
collection | PubMed |
description | Screen-printed graphite electrodes (SPGEs) have been used for the first time as platforms to detect oxygen gas in room-temperature ionic liquids (RTILs). Up until now, carbon-based SPEs have shown inferior behaviour compared to platinum and gold SPEs for gas sensing with RTIL solvents. The electrochemical reduction of oxygen (O(2)) in a range of RTILs has therefore been explored on home-made SPGEs, and is compared to the behaviour on commercially-available carbon SPEs (C-SPEs). Six common RTILs are initially employed for O(2) detection using cyclic voltammetry (CV), and two RTILs ([C(2)mim][NTf(2)] and [C(4)mim][PF(6)]) chosen for further detailed analytical studies. Long-term chronoamperometry (LTCA) was also performed to test the ability of the sensor surface for real-time gas monitoring. Both CV and LTCA gave linear calibration graphs—for CV in the 10–100% vol. range, and for LTCA in the 0.1–20% vol. range—on the SPGE. The responses on the SPGE were far superior to the commercial C-SPEs; more instability in the electrochemical responses were observed on the C-SPEs, together with some breaking-up or dissolution of the electrode surface materials. This study highlights that not all screen-printed ink formulations are compatible with RTIL solvents for longer-term electrochemical experiments, and that the choice of RTIL is also important. Overall, the low-cost SPGEs appear to be promising platforms for the detection of O(2), particularly in [C(4)mim][PF(6)]. |
format | Online Article Text |
id | pubmed-5751384 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-57513842018-01-10 Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids Lee, Junqiao Hussain, Ghulam Banks, Craig E. Silvester, Debbie S. Sensors (Basel) Article Screen-printed graphite electrodes (SPGEs) have been used for the first time as platforms to detect oxygen gas in room-temperature ionic liquids (RTILs). Up until now, carbon-based SPEs have shown inferior behaviour compared to platinum and gold SPEs for gas sensing with RTIL solvents. The electrochemical reduction of oxygen (O(2)) in a range of RTILs has therefore been explored on home-made SPGEs, and is compared to the behaviour on commercially-available carbon SPEs (C-SPEs). Six common RTILs are initially employed for O(2) detection using cyclic voltammetry (CV), and two RTILs ([C(2)mim][NTf(2)] and [C(4)mim][PF(6)]) chosen for further detailed analytical studies. Long-term chronoamperometry (LTCA) was also performed to test the ability of the sensor surface for real-time gas monitoring. Both CV and LTCA gave linear calibration graphs—for CV in the 10–100% vol. range, and for LTCA in the 0.1–20% vol. range—on the SPGE. The responses on the SPGE were far superior to the commercial C-SPEs; more instability in the electrochemical responses were observed on the C-SPEs, together with some breaking-up or dissolution of the electrode surface materials. This study highlights that not all screen-printed ink formulations are compatible with RTIL solvents for longer-term electrochemical experiments, and that the choice of RTIL is also important. Overall, the low-cost SPGEs appear to be promising platforms for the detection of O(2), particularly in [C(4)mim][PF(6)]. MDPI 2017-11-26 /pmc/articles/PMC5751384/ /pubmed/29186869 http://dx.doi.org/10.3390/s17122734 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Junqiao Hussain, Ghulam Banks, Craig E. Silvester, Debbie S. Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids |
title | Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids |
title_full | Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids |
title_fullStr | Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids |
title_full_unstemmed | Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids |
title_short | Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids |
title_sort | screen-printed graphite electrodes as low-cost devices for oxygen gas detection in room-temperature ionic liquids |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751384/ https://www.ncbi.nlm.nih.gov/pubmed/29186869 http://dx.doi.org/10.3390/s17122734 |
work_keys_str_mv | AT leejunqiao screenprintedgraphiteelectrodesaslowcostdevicesforoxygengasdetectioninroomtemperatureionicliquids AT hussainghulam screenprintedgraphiteelectrodesaslowcostdevicesforoxygengasdetectioninroomtemperatureionicliquids AT bankscraige screenprintedgraphiteelectrodesaslowcostdevicesforoxygengasdetectioninroomtemperatureionicliquids AT silvesterdebbies screenprintedgraphiteelectrodesaslowcostdevicesforoxygengasdetectioninroomtemperatureionicliquids |