Cargando…

Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images

Most of the existing calibration methods for binocular stereo vision sensor (BSVS) depend on a high-accuracy target with feature points that are difficult and costly to manufacture. In complex light conditions, optical filters are used for BSVS, but they affect imaging quality. Hence, the use of a h...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhen, Wu, Suining, Yin, Yang, Wu, Jinbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751521/
https://www.ncbi.nlm.nih.gov/pubmed/29236037
http://dx.doi.org/10.3390/s17122873
_version_ 1783289962752376832
author Liu, Zhen
Wu, Suining
Yin, Yang
Wu, Jinbo
author_facet Liu, Zhen
Wu, Suining
Yin, Yang
Wu, Jinbo
author_sort Liu, Zhen
collection PubMed
description Most of the existing calibration methods for binocular stereo vision sensor (BSVS) depend on a high-accuracy target with feature points that are difficult and costly to manufacture. In complex light conditions, optical filters are used for BSVS, but they affect imaging quality. Hence, the use of a high-accuracy target with certain-sized feature points for calibration is not feasible under such complex conditions. To solve these problems, a calibration method based on unknown-sized elliptical stripe images is proposed. With known intrinsic parameters, the proposed method adopts the elliptical stripes located on the parallel planes as a medium to calibrate BSVS online. In comparison with the common calibration methods, the proposed method avoids utilizing high-accuracy target with certain-sized feature points. Therefore, the proposed method is not only easy to implement but is a realistic method for the calibration of BSVS with optical filter. Changing the size of elliptical curves projected on the target solves the difficulty of applying the proposed method in different fields of view and distances. Simulative and physical experiments are conducted to validate the efficiency of the proposed method. When the field of view is approximately 400 mm × 300 mm, the proposed method can reach a calibration accuracy of 0.03 mm, which is comparable with that of Zhang’s method.
format Online
Article
Text
id pubmed-5751521
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57515212018-01-10 Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images Liu, Zhen Wu, Suining Yin, Yang Wu, Jinbo Sensors (Basel) Article Most of the existing calibration methods for binocular stereo vision sensor (BSVS) depend on a high-accuracy target with feature points that are difficult and costly to manufacture. In complex light conditions, optical filters are used for BSVS, but they affect imaging quality. Hence, the use of a high-accuracy target with certain-sized feature points for calibration is not feasible under such complex conditions. To solve these problems, a calibration method based on unknown-sized elliptical stripe images is proposed. With known intrinsic parameters, the proposed method adopts the elliptical stripes located on the parallel planes as a medium to calibrate BSVS online. In comparison with the common calibration methods, the proposed method avoids utilizing high-accuracy target with certain-sized feature points. Therefore, the proposed method is not only easy to implement but is a realistic method for the calibration of BSVS with optical filter. Changing the size of elliptical curves projected on the target solves the difficulty of applying the proposed method in different fields of view and distances. Simulative and physical experiments are conducted to validate the efficiency of the proposed method. When the field of view is approximately 400 mm × 300 mm, the proposed method can reach a calibration accuracy of 0.03 mm, which is comparable with that of Zhang’s method. MDPI 2017-12-13 /pmc/articles/PMC5751521/ /pubmed/29236037 http://dx.doi.org/10.3390/s17122873 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Zhen
Wu, Suining
Yin, Yang
Wu, Jinbo
Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images
title Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images
title_full Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images
title_fullStr Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images
title_full_unstemmed Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images
title_short Calibration of Binocular Vision Sensors Based on Unknown-Sized Elliptical Stripe Images
title_sort calibration of binocular vision sensors based on unknown-sized elliptical stripe images
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751521/
https://www.ncbi.nlm.nih.gov/pubmed/29236037
http://dx.doi.org/10.3390/s17122873
work_keys_str_mv AT liuzhen calibrationofbinocularvisionsensorsbasedonunknownsizedellipticalstripeimages
AT wusuining calibrationofbinocularvisionsensorsbasedonunknownsizedellipticalstripeimages
AT yinyang calibrationofbinocularvisionsensorsbasedonunknownsizedellipticalstripeimages
AT wujinbo calibrationofbinocularvisionsensorsbasedonunknownsizedellipticalstripeimages