Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator
Vibrothermography often employs a high-power actuator to generate heat on a specimen to reveal damage, however, the high-power actuator brings inconvenience to the application and possibly introduces additional damage to the inspected objects. This study uses a low-power piezoceramic transducer as t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751587/ https://www.ncbi.nlm.nih.gov/pubmed/29168759 http://dx.doi.org/10.3390/s17122705 |
_version_ | 1783289978208387072 |
---|---|
author | Xu, Changhang Xie, Jing Zhang, Wuyang Kong, Qingzhao Chen, Guoming Song, Gangbing |
author_facet | Xu, Changhang Xie, Jing Zhang, Wuyang Kong, Qingzhao Chen, Guoming Song, Gangbing |
author_sort | Xu, Changhang |
collection | PubMed |
description | Vibrothermography often employs a high-power actuator to generate heat on a specimen to reveal damage, however, the high-power actuator brings inconvenience to the application and possibly introduces additional damage to the inspected objects. This study uses a low-power piezoceramic transducer as the actuator of vibrothermography and explores its ability to detect multiple surface cracks in a metal part. Experiments were conducted on a thin aluminum beam with three cracks in different orientations. Detailed analyses of both thermograms and temperature data are presented to validate the proposed vibrothermography method. To further investigate the performance of the proposed vibrothermography method, we experimentally studied the effects of several critical factors, including the amplitude of excitation signal, specimen constraints, relative position between the transducer and cracks (the transducer is mounted on the same or the opposite side with the cracks). The results demonstrate that all cracks can be detected conveniently and simultaneously by using the proposed low-power vibrothermography. We also found that the magnitude of excitation signal and the specimen constraints have a great influence on detection results. Combined with effective data processing methods, such as Fourier transformation employed in this study, the proposed method provides a promising potential to detect multiple cracks on a metal surface in a safe and effective manner. |
format | Online Article Text |
id | pubmed-5751587 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-57515872018-01-10 Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator Xu, Changhang Xie, Jing Zhang, Wuyang Kong, Qingzhao Chen, Guoming Song, Gangbing Sensors (Basel) Article Vibrothermography often employs a high-power actuator to generate heat on a specimen to reveal damage, however, the high-power actuator brings inconvenience to the application and possibly introduces additional damage to the inspected objects. This study uses a low-power piezoceramic transducer as the actuator of vibrothermography and explores its ability to detect multiple surface cracks in a metal part. Experiments were conducted on a thin aluminum beam with three cracks in different orientations. Detailed analyses of both thermograms and temperature data are presented to validate the proposed vibrothermography method. To further investigate the performance of the proposed vibrothermography method, we experimentally studied the effects of several critical factors, including the amplitude of excitation signal, specimen constraints, relative position between the transducer and cracks (the transducer is mounted on the same or the opposite side with the cracks). The results demonstrate that all cracks can be detected conveniently and simultaneously by using the proposed low-power vibrothermography. We also found that the magnitude of excitation signal and the specimen constraints have a great influence on detection results. Combined with effective data processing methods, such as Fourier transformation employed in this study, the proposed method provides a promising potential to detect multiple cracks on a metal surface in a safe and effective manner. MDPI 2017-11-23 /pmc/articles/PMC5751587/ /pubmed/29168759 http://dx.doi.org/10.3390/s17122705 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xu, Changhang Xie, Jing Zhang, Wuyang Kong, Qingzhao Chen, Guoming Song, Gangbing Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator |
title | Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator |
title_full | Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator |
title_fullStr | Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator |
title_full_unstemmed | Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator |
title_short | Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator |
title_sort | experimental investigation on the detection of multiple surface cracks using vibrothermography with a low-power piezoceramic actuator |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751587/ https://www.ncbi.nlm.nih.gov/pubmed/29168759 http://dx.doi.org/10.3390/s17122705 |
work_keys_str_mv | AT xuchanghang experimentalinvestigationonthedetectionofmultiplesurfacecracksusingvibrothermographywithalowpowerpiezoceramicactuator AT xiejing experimentalinvestigationonthedetectionofmultiplesurfacecracksusingvibrothermographywithalowpowerpiezoceramicactuator AT zhangwuyang experimentalinvestigationonthedetectionofmultiplesurfacecracksusingvibrothermographywithalowpowerpiezoceramicactuator AT kongqingzhao experimentalinvestigationonthedetectionofmultiplesurfacecracksusingvibrothermographywithalowpowerpiezoceramicactuator AT chenguoming experimentalinvestigationonthedetectionofmultiplesurfacecracksusingvibrothermographywithalowpowerpiezoceramicactuator AT songgangbing experimentalinvestigationonthedetectionofmultiplesurfacecracksusingvibrothermographywithalowpowerpiezoceramicactuator |