Cargando…
Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results
Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751656/ https://www.ncbi.nlm.nih.gov/pubmed/29257045 http://dx.doi.org/10.3390/s17122944 |
_version_ | 1783289994290397184 |
---|---|
author | Rodrigues, Domingos M. C. Lopes, Rafaela N. Franco, Marcos A. R. Werneck, Marcelo M. Allil, Regina C. S. B. |
author_facet | Rodrigues, Domingos M. C. Lopes, Rafaela N. Franco, Marcos A. R. Werneck, Marcelo M. Allil, Regina C. S. B. |
author_sort | Rodrigues, Domingos M. C. |
collection | PubMed |
description | Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI) sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli. Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity. |
format | Online Article Text |
id | pubmed-5751656 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-57516562018-01-10 Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results Rodrigues, Domingos M. C. Lopes, Rafaela N. Franco, Marcos A. R. Werneck, Marcelo M. Allil, Regina C. S. B. Sensors (Basel) Article Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI) sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli. Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity. MDPI 2017-12-19 /pmc/articles/PMC5751656/ /pubmed/29257045 http://dx.doi.org/10.3390/s17122944 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rodrigues, Domingos M. C. Lopes, Rafaela N. Franco, Marcos A. R. Werneck, Marcelo M. Allil, Regina C. S. B. Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results |
title | Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results |
title_full | Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results |
title_fullStr | Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results |
title_full_unstemmed | Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results |
title_short | Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results |
title_sort | sensitivity analysis of different shapes of a plastic optical fiber-based immunosensor for escherichia coli: simulation and experimental results |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751656/ https://www.ncbi.nlm.nih.gov/pubmed/29257045 http://dx.doi.org/10.3390/s17122944 |
work_keys_str_mv | AT rodriguesdomingosmc sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults AT lopesrafaelan sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults AT francomarcosar sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults AT werneckmarcelom sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults AT allilreginacsb sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults |