Cargando…

Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results

Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodrigues, Domingos M. C., Lopes, Rafaela N., Franco, Marcos A. R., Werneck, Marcelo M., Allil, Regina C. S. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751656/
https://www.ncbi.nlm.nih.gov/pubmed/29257045
http://dx.doi.org/10.3390/s17122944
_version_ 1783289994290397184
author Rodrigues, Domingos M. C.
Lopes, Rafaela N.
Franco, Marcos A. R.
Werneck, Marcelo M.
Allil, Regina C. S. B.
author_facet Rodrigues, Domingos M. C.
Lopes, Rafaela N.
Franco, Marcos A. R.
Werneck, Marcelo M.
Allil, Regina C. S. B.
author_sort Rodrigues, Domingos M. C.
collection PubMed
description Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI) sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli. Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity.
format Online
Article
Text
id pubmed-5751656
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57516562018-01-10 Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results Rodrigues, Domingos M. C. Lopes, Rafaela N. Franco, Marcos A. R. Werneck, Marcelo M. Allil, Regina C. S. B. Sensors (Basel) Article Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI) sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli. Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity. MDPI 2017-12-19 /pmc/articles/PMC5751656/ /pubmed/29257045 http://dx.doi.org/10.3390/s17122944 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rodrigues, Domingos M. C.
Lopes, Rafaela N.
Franco, Marcos A. R.
Werneck, Marcelo M.
Allil, Regina C. S. B.
Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results
title Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results
title_full Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results
title_fullStr Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results
title_full_unstemmed Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results
title_short Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results
title_sort sensitivity analysis of different shapes of a plastic optical fiber-based immunosensor for escherichia coli: simulation and experimental results
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751656/
https://www.ncbi.nlm.nih.gov/pubmed/29257045
http://dx.doi.org/10.3390/s17122944
work_keys_str_mv AT rodriguesdomingosmc sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults
AT lopesrafaelan sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults
AT francomarcosar sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults
AT werneckmarcelom sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults
AT allilreginacsb sensitivityanalysisofdifferentshapesofaplasticopticalfiberbasedimmunosensorforescherichiacolisimulationandexperimentalresults