Cargando…

Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk

PURPOSE: To assess the effect of a shrinking rectal balloon implant (RBI) on the anorectal dose and complication risk during the course of moderately hypofractionated prostate radiotherapy. METHODS: In 15 patients with localized prostate cancer, an RBI was implanted. A weekly kilovolt cone-beam comp...

Descripción completa

Detalles Bibliográficos
Autores principales: Vanneste, Ben G. L., van Wijk, Y., Lutgens, L. C., Van Limbergen, E. J., van Lin, E. N., van de Beek, K., Lambin, P., Hoffmann, A. L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5752748/
https://www.ncbi.nlm.nih.gov/pubmed/29038832
http://dx.doi.org/10.1007/s00066-017-1222-x
_version_ 1783290156295389184
author Vanneste, Ben G. L.
van Wijk, Y.
Lutgens, L. C.
Van Limbergen, E. J.
van Lin, E. N.
van de Beek, K.
Lambin, P.
Hoffmann, A. L.
author_facet Vanneste, Ben G. L.
van Wijk, Y.
Lutgens, L. C.
Van Limbergen, E. J.
van Lin, E. N.
van de Beek, K.
Lambin, P.
Hoffmann, A. L.
author_sort Vanneste, Ben G. L.
collection PubMed
description PURPOSE: To assess the effect of a shrinking rectal balloon implant (RBI) on the anorectal dose and complication risk during the course of moderately hypofractionated prostate radiotherapy. METHODS: In 15 patients with localized prostate cancer, an RBI was implanted. A weekly kilovolt cone-beam computed tomography (CBCT) scan was acquired to measure the dynamics of RBI volume and prostate–rectum separation. The absolute anorectal volume encompassed by the 2 Gy equieffective 75 Gy isodose (V(75Gy)) was recalculated as well as the mean anorectal dose. The increase in estimated risk of grade 2–3 late rectal bleeding (LRB) between the start and end of treatment was predicted using nomograms. The observed acute and late toxicities were evaluated. RESULTS: A significant shrinkage of RBI volumes was observed, with an average volume of 70.4% of baseline at the end of the treatment. Although the prostate–rectum separation significantly decreased over time, it remained at least 1 cm. No significant increase in V(75Gy) of the anorectum was observed, except in one patient whose RBI had completely deflated in the third week of treatment. No correlation between mean anorectal dose and balloon deflation was found. The increase in predicted LRB risk was not significant, except in the one patient whose RBI completely deflated. The observed toxicities confirmed these findings. CONCLUSIONS: Despite significant decrease in RBI volume the high-dose rectal volume and the predicted LRB risk were unaffected due to a persistent spacing between the prostate and the anterior rectal wall.
format Online
Article
Text
id pubmed-5752748
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-57527482018-01-22 Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk Vanneste, Ben G. L. van Wijk, Y. Lutgens, L. C. Van Limbergen, E. J. van Lin, E. N. van de Beek, K. Lambin, P. Hoffmann, A. L. Strahlenther Onkol Original Article PURPOSE: To assess the effect of a shrinking rectal balloon implant (RBI) on the anorectal dose and complication risk during the course of moderately hypofractionated prostate radiotherapy. METHODS: In 15 patients with localized prostate cancer, an RBI was implanted. A weekly kilovolt cone-beam computed tomography (CBCT) scan was acquired to measure the dynamics of RBI volume and prostate–rectum separation. The absolute anorectal volume encompassed by the 2 Gy equieffective 75 Gy isodose (V(75Gy)) was recalculated as well as the mean anorectal dose. The increase in estimated risk of grade 2–3 late rectal bleeding (LRB) between the start and end of treatment was predicted using nomograms. The observed acute and late toxicities were evaluated. RESULTS: A significant shrinkage of RBI volumes was observed, with an average volume of 70.4% of baseline at the end of the treatment. Although the prostate–rectum separation significantly decreased over time, it remained at least 1 cm. No significant increase in V(75Gy) of the anorectum was observed, except in one patient whose RBI had completely deflated in the third week of treatment. No correlation between mean anorectal dose and balloon deflation was found. The increase in predicted LRB risk was not significant, except in the one patient whose RBI completely deflated. The observed toxicities confirmed these findings. CONCLUSIONS: Despite significant decrease in RBI volume the high-dose rectal volume and the predicted LRB risk were unaffected due to a persistent spacing between the prostate and the anterior rectal wall. Springer Berlin Heidelberg 2017-10-16 2018 /pmc/articles/PMC5752748/ /pubmed/29038832 http://dx.doi.org/10.1007/s00066-017-1222-x Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Vanneste, Ben G. L.
van Wijk, Y.
Lutgens, L. C.
Van Limbergen, E. J.
van Lin, E. N.
van de Beek, K.
Lambin, P.
Hoffmann, A. L.
Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk
title Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk
title_full Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk
title_fullStr Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk
title_full_unstemmed Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk
title_short Dynamics of rectal balloon implant shrinkage in prostate VMAT: Influence on anorectal dose and late rectal complication risk
title_sort dynamics of rectal balloon implant shrinkage in prostate vmat: influence on anorectal dose and late rectal complication risk
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5752748/
https://www.ncbi.nlm.nih.gov/pubmed/29038832
http://dx.doi.org/10.1007/s00066-017-1222-x
work_keys_str_mv AT vannestebengl dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk
AT vanwijky dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk
AT lutgenslc dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk
AT vanlimbergenej dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk
AT vanlinen dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk
AT vandebeekk dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk
AT lambinp dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk
AT hoffmannal dynamicsofrectalballoonimplantshrinkageinprostatevmatinfluenceonanorectaldoseandlaterectalcomplicationrisk