Cargando…

Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre

INTRODUCTION: Radiation exposure from intra-operative fluoroscopy in orthopaedic trauma surgery is a common occupational hazard. References for fluoroscopy use in the operating room for commonly performed operations have not been reported adequately. This study aimed to report appropriate intra-oper...

Descripción completa

Detalles Bibliográficos
Autores principales: Rashid, Mustafa S., Aziz, Sheweidin, Haydar, Syed, Fleming, Simon S., Datta, Amit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5754436/
https://www.ncbi.nlm.nih.gov/pubmed/28798994
http://dx.doi.org/10.1007/s00590-017-2020-y
_version_ 1783290416451289088
author Rashid, Mustafa S.
Aziz, Sheweidin
Haydar, Syed
Fleming, Simon S.
Datta, Amit
author_facet Rashid, Mustafa S.
Aziz, Sheweidin
Haydar, Syed
Fleming, Simon S.
Datta, Amit
author_sort Rashid, Mustafa S.
collection PubMed
description INTRODUCTION: Radiation exposure from intra-operative fluoroscopy in orthopaedic trauma surgery is a common occupational hazard. References for fluoroscopy use in the operating room for commonly performed operations have not been reported adequately. This study aimed to report appropriate intra-operative fluoroscopy use in orthopaedic trauma and compare the effect of surgery type and surgeon grade on radiation exposure. METHODS: Data on 849 cases over an 18-month period were analysed retrospectively. Median and 75th centile values for dose area product (DAP), screening time (ST), and number of fluoroscopy images were calculated for procedures where n > 9 (n = 808). RESULTS: Median DAP for dynamic hip screws for extracapsular femoral neck fractures was 668 mGy/cm(2) (ST 36 s), 1040 mGy/cm(2) (ST 49 s) for short proximal femoral nail, 1720 mGy/cm(2) (ST 2 m 36 s) for long femoral nail for diaphyseal fractures, 25 mGy/cm(2) (ST 25 s) for manipulation and Kirschner wire fixation in distal radius fractures, and 27 mGy/cm(2) (ST 23 s) for volar locking plate fixation in distal radius fractures. These represented the five commonest procedures performed in the trauma operating room in our hospital. Experienced surgeons utilized less radiation in the operating room than junior surgeons (DAP 90.55 vs. 366.5 mGy/cm(2), p = 0.001) and took fewer fluoroscopic images (49 vs. 66, p = 0.008) overall. CONCLUSIONS: This study reports reference values for common trauma operations. These can be utilized by surgeons in the operating room to raise awareness and perform clinical audits of appropriate fluoroscopy use for orthopaedic trauma, using this study as guidance for standards. We demonstrated a significant reduction in fluoroscopy usage with increasing surgeon experience.
format Online
Article
Text
id pubmed-5754436
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-57544362018-01-22 Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre Rashid, Mustafa S. Aziz, Sheweidin Haydar, Syed Fleming, Simon S. Datta, Amit Eur J Orthop Surg Traumatol Original Article • GENERAL ORTHOPAEDICS - RADIOLOGY INTRODUCTION: Radiation exposure from intra-operative fluoroscopy in orthopaedic trauma surgery is a common occupational hazard. References for fluoroscopy use in the operating room for commonly performed operations have not been reported adequately. This study aimed to report appropriate intra-operative fluoroscopy use in orthopaedic trauma and compare the effect of surgery type and surgeon grade on radiation exposure. METHODS: Data on 849 cases over an 18-month period were analysed retrospectively. Median and 75th centile values for dose area product (DAP), screening time (ST), and number of fluoroscopy images were calculated for procedures where n > 9 (n = 808). RESULTS: Median DAP for dynamic hip screws for extracapsular femoral neck fractures was 668 mGy/cm(2) (ST 36 s), 1040 mGy/cm(2) (ST 49 s) for short proximal femoral nail, 1720 mGy/cm(2) (ST 2 m 36 s) for long femoral nail for diaphyseal fractures, 25 mGy/cm(2) (ST 25 s) for manipulation and Kirschner wire fixation in distal radius fractures, and 27 mGy/cm(2) (ST 23 s) for volar locking plate fixation in distal radius fractures. These represented the five commonest procedures performed in the trauma operating room in our hospital. Experienced surgeons utilized less radiation in the operating room than junior surgeons (DAP 90.55 vs. 366.5 mGy/cm(2), p = 0.001) and took fewer fluoroscopic images (49 vs. 66, p = 0.008) overall. CONCLUSIONS: This study reports reference values for common trauma operations. These can be utilized by surgeons in the operating room to raise awareness and perform clinical audits of appropriate fluoroscopy use for orthopaedic trauma, using this study as guidance for standards. We demonstrated a significant reduction in fluoroscopy usage with increasing surgeon experience. Springer Paris 2017-08-10 2018 /pmc/articles/PMC5754436/ /pubmed/28798994 http://dx.doi.org/10.1007/s00590-017-2020-y Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article • GENERAL ORTHOPAEDICS - RADIOLOGY
Rashid, Mustafa S.
Aziz, Sheweidin
Haydar, Syed
Fleming, Simon S.
Datta, Amit
Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre
title Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre
title_full Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre
title_fullStr Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre
title_full_unstemmed Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre
title_short Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre
title_sort intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre
topic Original Article • GENERAL ORTHOPAEDICS - RADIOLOGY
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5754436/
https://www.ncbi.nlm.nih.gov/pubmed/28798994
http://dx.doi.org/10.1007/s00590-017-2020-y
work_keys_str_mv AT rashidmustafas intraoperativefluoroscopicradiationexposureinorthopaedictraumatheatre
AT azizsheweidin intraoperativefluoroscopicradiationexposureinorthopaedictraumatheatre
AT haydarsyed intraoperativefluoroscopicradiationexposureinorthopaedictraumatheatre
AT flemingsimons intraoperativefluoroscopicradiationexposureinorthopaedictraumatheatre
AT dattaamit intraoperativefluoroscopicradiationexposureinorthopaedictraumatheatre