Cargando…

Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides

BACKGROUND: Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. MATERIAL/METHODS: A...

Descripción completa

Detalles Bibliográficos
Autor principal: Çalbıyık, Murat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5755952/
https://www.ncbi.nlm.nih.gov/pubmed/29287060
http://dx.doi.org/10.12659/MSM.908213
_version_ 1783290665306685440
author Çalbıyık, Murat
author_facet Çalbıyık, Murat
author_sort Çalbıyık, Murat
collection PubMed
description BACKGROUND: Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. MATERIAL/METHODS: A total of 36 patients (mean age, 67.58±8.46 years; 24 females, 12 males) who underwent TKA with 3D patient-specific cutting guides in our clinic were included in the study. Differences between preoperatively planned bone resections and actual bone resections were calculated. Femoral and tibial component angles were measured on radiographs of the knee. The change in knee pain was evaluated by patients on a 10-point visual analog scale (VAS). Patients were followed up for 6 months postoperatively. RESULTS: The actual bone resection was 0.5–1.5 mm higher than the planned resection for all sides, being statistically significant for posterior lateral and distal medial sides (1.1±1.3 mm and 1.5±0.9 mm, respectively; p<0.05). On postoperative radiographs, coronal tibial component angle was 88.8°±0.9° and coronal femoral component angle was 95.2°±1.6°, showing good postoperative alignment. The VAS pain score of patients significantly decreased from preoperative 3.9±0.8 to 1.1±0.9 at 6 months after the operation. One patient developed superficial tissue infection on postoperative follow-up, which was effectively treated. No other pathology was detected in the postoperative period. CONCLUSIONS: Patient-specific cutting guides can provide intraoperative guidance for better placement of the implant in TKA and increase the accuracy of osteotomy and postoperative alignment.
format Online
Article
Text
id pubmed-5755952
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-57559522018-01-10 Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides Çalbıyık, Murat Med Sci Monit Clinical Research BACKGROUND: Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. MATERIAL/METHODS: A total of 36 patients (mean age, 67.58±8.46 years; 24 females, 12 males) who underwent TKA with 3D patient-specific cutting guides in our clinic were included in the study. Differences between preoperatively planned bone resections and actual bone resections were calculated. Femoral and tibial component angles were measured on radiographs of the knee. The change in knee pain was evaluated by patients on a 10-point visual analog scale (VAS). Patients were followed up for 6 months postoperatively. RESULTS: The actual bone resection was 0.5–1.5 mm higher than the planned resection for all sides, being statistically significant for posterior lateral and distal medial sides (1.1±1.3 mm and 1.5±0.9 mm, respectively; p<0.05). On postoperative radiographs, coronal tibial component angle was 88.8°±0.9° and coronal femoral component angle was 95.2°±1.6°, showing good postoperative alignment. The VAS pain score of patients significantly decreased from preoperative 3.9±0.8 to 1.1±0.9 at 6 months after the operation. One patient developed superficial tissue infection on postoperative follow-up, which was effectively treated. No other pathology was detected in the postoperative period. CONCLUSIONS: Patient-specific cutting guides can provide intraoperative guidance for better placement of the implant in TKA and increase the accuracy of osteotomy and postoperative alignment. International Scientific Literature, Inc. 2017-12-29 /pmc/articles/PMC5755952/ /pubmed/29287060 http://dx.doi.org/10.12659/MSM.908213 Text en © Med Sci Monit, 2017 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Çalbıyık, Murat
Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides
title Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides
title_full Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides
title_fullStr Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides
title_full_unstemmed Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides
title_short Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides
title_sort clinical outcome of total knee arthroplasty performed using patient-specific cutting guides
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5755952/
https://www.ncbi.nlm.nih.gov/pubmed/29287060
http://dx.doi.org/10.12659/MSM.908213
work_keys_str_mv AT calbıyıkmurat clinicaloutcomeoftotalkneearthroplastyperformedusingpatientspecificcuttingguides