Cargando…
Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides
BACKGROUND: Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. MATERIAL/METHODS: A...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5755952/ https://www.ncbi.nlm.nih.gov/pubmed/29287060 http://dx.doi.org/10.12659/MSM.908213 |
_version_ | 1783290665306685440 |
---|---|
author | Çalbıyık, Murat |
author_facet | Çalbıyık, Murat |
author_sort | Çalbıyık, Murat |
collection | PubMed |
description | BACKGROUND: Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. MATERIAL/METHODS: A total of 36 patients (mean age, 67.58±8.46 years; 24 females, 12 males) who underwent TKA with 3D patient-specific cutting guides in our clinic were included in the study. Differences between preoperatively planned bone resections and actual bone resections were calculated. Femoral and tibial component angles were measured on radiographs of the knee. The change in knee pain was evaluated by patients on a 10-point visual analog scale (VAS). Patients were followed up for 6 months postoperatively. RESULTS: The actual bone resection was 0.5–1.5 mm higher than the planned resection for all sides, being statistically significant for posterior lateral and distal medial sides (1.1±1.3 mm and 1.5±0.9 mm, respectively; p<0.05). On postoperative radiographs, coronal tibial component angle was 88.8°±0.9° and coronal femoral component angle was 95.2°±1.6°, showing good postoperative alignment. The VAS pain score of patients significantly decreased from preoperative 3.9±0.8 to 1.1±0.9 at 6 months after the operation. One patient developed superficial tissue infection on postoperative follow-up, which was effectively treated. No other pathology was detected in the postoperative period. CONCLUSIONS: Patient-specific cutting guides can provide intraoperative guidance for better placement of the implant in TKA and increase the accuracy of osteotomy and postoperative alignment. |
format | Online Article Text |
id | pubmed-5755952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57559522018-01-10 Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides Çalbıyık, Murat Med Sci Monit Clinical Research BACKGROUND: Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. MATERIAL/METHODS: A total of 36 patients (mean age, 67.58±8.46 years; 24 females, 12 males) who underwent TKA with 3D patient-specific cutting guides in our clinic were included in the study. Differences between preoperatively planned bone resections and actual bone resections were calculated. Femoral and tibial component angles were measured on radiographs of the knee. The change in knee pain was evaluated by patients on a 10-point visual analog scale (VAS). Patients were followed up for 6 months postoperatively. RESULTS: The actual bone resection was 0.5–1.5 mm higher than the planned resection for all sides, being statistically significant for posterior lateral and distal medial sides (1.1±1.3 mm and 1.5±0.9 mm, respectively; p<0.05). On postoperative radiographs, coronal tibial component angle was 88.8°±0.9° and coronal femoral component angle was 95.2°±1.6°, showing good postoperative alignment. The VAS pain score of patients significantly decreased from preoperative 3.9±0.8 to 1.1±0.9 at 6 months after the operation. One patient developed superficial tissue infection on postoperative follow-up, which was effectively treated. No other pathology was detected in the postoperative period. CONCLUSIONS: Patient-specific cutting guides can provide intraoperative guidance for better placement of the implant in TKA and increase the accuracy of osteotomy and postoperative alignment. International Scientific Literature, Inc. 2017-12-29 /pmc/articles/PMC5755952/ /pubmed/29287060 http://dx.doi.org/10.12659/MSM.908213 Text en © Med Sci Monit, 2017 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Çalbıyık, Murat Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides |
title | Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides |
title_full | Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides |
title_fullStr | Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides |
title_full_unstemmed | Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides |
title_short | Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides |
title_sort | clinical outcome of total knee arthroplasty performed using patient-specific cutting guides |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5755952/ https://www.ncbi.nlm.nih.gov/pubmed/29287060 http://dx.doi.org/10.12659/MSM.908213 |
work_keys_str_mv | AT calbıyıkmurat clinicaloutcomeoftotalkneearthroplastyperformedusingpatientspecificcuttingguides |