Cargando…

Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management

BACKGROUND: Colposcopy is subjective and management of young patients with high-grade disease is challenging, as treatments may impair subsequent pregnancies and adversely affect obstetric outcomes. Conservative management of selected patients is becoming more popular amongst clinicians; however it...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaufmann, Angelika, Founta, Christina, Papagiannakis, Emmanouil, Naik, Raj, Fisher, Ann
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5757110/
https://www.ncbi.nlm.nih.gov/pubmed/29435378
http://dx.doi.org/10.1155/2017/5269279
_version_ 1783290804931919872
author Kaufmann, Angelika
Founta, Christina
Papagiannakis, Emmanouil
Naik, Raj
Fisher, Ann
author_facet Kaufmann, Angelika
Founta, Christina
Papagiannakis, Emmanouil
Naik, Raj
Fisher, Ann
author_sort Kaufmann, Angelika
collection PubMed
description BACKGROUND: Colposcopy is subjective and management of young patients with high-grade disease is challenging, as treatments may impair subsequent pregnancies and adversely affect obstetric outcomes. Conservative management of selected patients is becoming more popular amongst clinicians; however it requires accurate assessment and documentation. Novel adjunctive technologies for colposcopy could improve patient care and help individualize management decisions by introducing standardization, increasing sensitivity, and improving documentation. CASE: A nulliparous 27-year-old woman planning pregnancy underwent colposcopy following high-grade cytology. The colposcopic impression was of low-grade changes, whilst the Dynamic Spectral Imaging (DSI) map of the cervix suggested potential high-grade. A DSI-directed biopsy confirmed CIN2. At follow-up, both colposcopy and DSI were suggestive of low-grade disease only, and image comparison confirmed the absence of previously present acetowhite epithelium areas. Histology of the transformation zone following excisional treatment, as per patient's choice, showed no high-grade changes. CONCLUSION: Digital colposcopy with DSI mapping helps standardize colposcopic examinations, increase diagnostic accuracy, and monitor cervical changes over time, improving patient care. When used for longitudinal tracking of disease and when it confirms a negative colposcopy, it can help towards avoiding overtreatment and hence decrease morbidity related to cervical excision.
format Online
Article
Text
id pubmed-5757110
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-57571102018-02-12 Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management Kaufmann, Angelika Founta, Christina Papagiannakis, Emmanouil Naik, Raj Fisher, Ann Case Rep Obstet Gynecol Case Report BACKGROUND: Colposcopy is subjective and management of young patients with high-grade disease is challenging, as treatments may impair subsequent pregnancies and adversely affect obstetric outcomes. Conservative management of selected patients is becoming more popular amongst clinicians; however it requires accurate assessment and documentation. Novel adjunctive technologies for colposcopy could improve patient care and help individualize management decisions by introducing standardization, increasing sensitivity, and improving documentation. CASE: A nulliparous 27-year-old woman planning pregnancy underwent colposcopy following high-grade cytology. The colposcopic impression was of low-grade changes, whilst the Dynamic Spectral Imaging (DSI) map of the cervix suggested potential high-grade. A DSI-directed biopsy confirmed CIN2. At follow-up, both colposcopy and DSI were suggestive of low-grade disease only, and image comparison confirmed the absence of previously present acetowhite epithelium areas. Histology of the transformation zone following excisional treatment, as per patient's choice, showed no high-grade changes. CONCLUSION: Digital colposcopy with DSI mapping helps standardize colposcopic examinations, increase diagnostic accuracy, and monitor cervical changes over time, improving patient care. When used for longitudinal tracking of disease and when it confirms a negative colposcopy, it can help towards avoiding overtreatment and hence decrease morbidity related to cervical excision. Hindawi 2017 2017-12-25 /pmc/articles/PMC5757110/ /pubmed/29435378 http://dx.doi.org/10.1155/2017/5269279 Text en Copyright © 2017 Angelika Kaufmann et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Kaufmann, Angelika
Founta, Christina
Papagiannakis, Emmanouil
Naik, Raj
Fisher, Ann
Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management
title Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management
title_full Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management
title_fullStr Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management
title_full_unstemmed Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management
title_short Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management
title_sort standardized digital colposcopy with dynamic spectral imaging for conservative patient management
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5757110/
https://www.ncbi.nlm.nih.gov/pubmed/29435378
http://dx.doi.org/10.1155/2017/5269279
work_keys_str_mv AT kaufmannangelika standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement
AT fountachristina standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement
AT papagiannakisemmanouil standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement
AT naikraj standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement
AT fisherann standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement