Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management
BACKGROUND: Colposcopy is subjective and management of young patients with high-grade disease is challenging, as treatments may impair subsequent pregnancies and adversely affect obstetric outcomes. Conservative management of selected patients is becoming more popular amongst clinicians; however it...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5757110/ https://www.ncbi.nlm.nih.gov/pubmed/29435378 http://dx.doi.org/10.1155/2017/5269279 |
_version_ | 1783290804931919872 |
---|---|
author | Kaufmann, Angelika Founta, Christina Papagiannakis, Emmanouil Naik, Raj Fisher, Ann |
author_facet | Kaufmann, Angelika Founta, Christina Papagiannakis, Emmanouil Naik, Raj Fisher, Ann |
author_sort | Kaufmann, Angelika |
collection | PubMed |
description | BACKGROUND: Colposcopy is subjective and management of young patients with high-grade disease is challenging, as treatments may impair subsequent pregnancies and adversely affect obstetric outcomes. Conservative management of selected patients is becoming more popular amongst clinicians; however it requires accurate assessment and documentation. Novel adjunctive technologies for colposcopy could improve patient care and help individualize management decisions by introducing standardization, increasing sensitivity, and improving documentation. CASE: A nulliparous 27-year-old woman planning pregnancy underwent colposcopy following high-grade cytology. The colposcopic impression was of low-grade changes, whilst the Dynamic Spectral Imaging (DSI) map of the cervix suggested potential high-grade. A DSI-directed biopsy confirmed CIN2. At follow-up, both colposcopy and DSI were suggestive of low-grade disease only, and image comparison confirmed the absence of previously present acetowhite epithelium areas. Histology of the transformation zone following excisional treatment, as per patient's choice, showed no high-grade changes. CONCLUSION: Digital colposcopy with DSI mapping helps standardize colposcopic examinations, increase diagnostic accuracy, and monitor cervical changes over time, improving patient care. When used for longitudinal tracking of disease and when it confirms a negative colposcopy, it can help towards avoiding overtreatment and hence decrease morbidity related to cervical excision. |
format | Online Article Text |
id | pubmed-5757110 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-57571102018-02-12 Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management Kaufmann, Angelika Founta, Christina Papagiannakis, Emmanouil Naik, Raj Fisher, Ann Case Rep Obstet Gynecol Case Report BACKGROUND: Colposcopy is subjective and management of young patients with high-grade disease is challenging, as treatments may impair subsequent pregnancies and adversely affect obstetric outcomes. Conservative management of selected patients is becoming more popular amongst clinicians; however it requires accurate assessment and documentation. Novel adjunctive technologies for colposcopy could improve patient care and help individualize management decisions by introducing standardization, increasing sensitivity, and improving documentation. CASE: A nulliparous 27-year-old woman planning pregnancy underwent colposcopy following high-grade cytology. The colposcopic impression was of low-grade changes, whilst the Dynamic Spectral Imaging (DSI) map of the cervix suggested potential high-grade. A DSI-directed biopsy confirmed CIN2. At follow-up, both colposcopy and DSI were suggestive of low-grade disease only, and image comparison confirmed the absence of previously present acetowhite epithelium areas. Histology of the transformation zone following excisional treatment, as per patient's choice, showed no high-grade changes. CONCLUSION: Digital colposcopy with DSI mapping helps standardize colposcopic examinations, increase diagnostic accuracy, and monitor cervical changes over time, improving patient care. When used for longitudinal tracking of disease and when it confirms a negative colposcopy, it can help towards avoiding overtreatment and hence decrease morbidity related to cervical excision. Hindawi 2017 2017-12-25 /pmc/articles/PMC5757110/ /pubmed/29435378 http://dx.doi.org/10.1155/2017/5269279 Text en Copyright © 2017 Angelika Kaufmann et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Kaufmann, Angelika Founta, Christina Papagiannakis, Emmanouil Naik, Raj Fisher, Ann Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management |
title | Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management |
title_full | Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management |
title_fullStr | Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management |
title_full_unstemmed | Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management |
title_short | Standardized Digital Colposcopy with Dynamic Spectral Imaging for Conservative Patient Management |
title_sort | standardized digital colposcopy with dynamic spectral imaging for conservative patient management |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5757110/ https://www.ncbi.nlm.nih.gov/pubmed/29435378 http://dx.doi.org/10.1155/2017/5269279 |
work_keys_str_mv | AT kaufmannangelika standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement AT fountachristina standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement AT papagiannakisemmanouil standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement AT naikraj standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement AT fisherann standardizeddigitalcolposcopywithdynamicspectralimagingforconservativepatientmanagement |