Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report
RATIONALE: Longitudinal stent compression is a rare phenomenon, which has been increasingly reported in recent years. PATIENT CONCERNS: Following 2 stents implanted into the middle and proximal segments of the left anterior descending (LAD) artery, longitudinal stent compression occurred when a post...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5758258/ https://www.ncbi.nlm.nih.gov/pubmed/29390556 http://dx.doi.org/10.1097/MD.0000000000009405 |
_version_ | 1783290976780943360 |
---|---|
author | Si, Daoyuan Yang, Hongliang Liu, Guohui Tong, Yaliang He, Yuquan |
author_facet | Si, Daoyuan Yang, Hongliang Liu, Guohui Tong, Yaliang He, Yuquan |
author_sort | Si, Daoyuan |
collection | PubMed |
description | RATIONALE: Longitudinal stent compression is a rare phenomenon, which has been increasingly reported in recent years. PATIENT CONCERNS: Following 2 stents implanted into the middle and proximal segments of the left anterior descending (LAD) artery, longitudinal stent compression occurred when a post-dilation balloon was introduced into the proximal stent opening. DIAGNOSE: The intravenous ultrasound (IVUS) examination revealed overlapping at the opening of the proximal stent and poor stent adherence. INTERVENTIONS: Another balloon was carefully inserted into the opening for post-dilation, followed by angiography and IVUS examination. OUTCOMES: The IVUS examination indicated that the overlapping at the opening of the proximal stent was improved and the stents were well adhered. LESSONS: Such compression may be prevented by gentle and careful balloon maneuverability and improved with the use of additional balloon angioplasty or stent implantation. |
format | Online Article Text |
id | pubmed-5758258 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-57582582018-01-29 Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report Si, Daoyuan Yang, Hongliang Liu, Guohui Tong, Yaliang He, Yuquan Medicine (Baltimore) 3400 RATIONALE: Longitudinal stent compression is a rare phenomenon, which has been increasingly reported in recent years. PATIENT CONCERNS: Following 2 stents implanted into the middle and proximal segments of the left anterior descending (LAD) artery, longitudinal stent compression occurred when a post-dilation balloon was introduced into the proximal stent opening. DIAGNOSE: The intravenous ultrasound (IVUS) examination revealed overlapping at the opening of the proximal stent and poor stent adherence. INTERVENTIONS: Another balloon was carefully inserted into the opening for post-dilation, followed by angiography and IVUS examination. OUTCOMES: The IVUS examination indicated that the overlapping at the opening of the proximal stent was improved and the stents were well adhered. LESSONS: Such compression may be prevented by gentle and careful balloon maneuverability and improved with the use of additional balloon angioplasty or stent implantation. Wolters Kluwer Health 2017-12-22 /pmc/articles/PMC5758258/ /pubmed/29390556 http://dx.doi.org/10.1097/MD.0000000000009405 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 3400 Si, Daoyuan Yang, Hongliang Liu, Guohui Tong, Yaliang He, Yuquan Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report |
title | Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report |
title_full | Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report |
title_fullStr | Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report |
title_full_unstemmed | Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report |
title_short | Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report |
title_sort | treatment of longitudinal stent compression under intravenous ultrasound guidance: a case report |
topic | 3400 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5758258/ https://www.ncbi.nlm.nih.gov/pubmed/29390556 http://dx.doi.org/10.1097/MD.0000000000009405 |
work_keys_str_mv | AT sidaoyuan treatmentoflongitudinalstentcompressionunderintravenousultrasoundguidanceacasereport AT yanghongliang treatmentoflongitudinalstentcompressionunderintravenousultrasoundguidanceacasereport AT liuguohui treatmentoflongitudinalstentcompressionunderintravenousultrasoundguidanceacasereport AT tongyaliang treatmentoflongitudinalstentcompressionunderintravenousultrasoundguidanceacasereport AT heyuquan treatmentoflongitudinalstentcompressionunderintravenousultrasoundguidanceacasereport |