Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair
PURPOSE: To evaluate the value of single-energy metal artifact reduction (SEMAR) algorithm on image quality in patients after complex endovascular aortic repair (EVAR) with fenestrated and branched devices. METHODS: Routine follow-up computed tomography angiography (CTA) examinations were performed...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5758681/ https://www.ncbi.nlm.nih.gov/pubmed/29086057 http://dx.doi.org/10.1007/s00270-017-1812-0 |
_version_ | 1783291038594498560 |
---|---|
author | Ragusi, M. A. A. D. van der Meer, R. W. Joemai, R. M. S. van Schaik, J. van Rijswijk, C. S. P. |
author_facet | Ragusi, M. A. A. D. van der Meer, R. W. Joemai, R. M. S. van Schaik, J. van Rijswijk, C. S. P. |
author_sort | Ragusi, M. A. A. D. |
collection | PubMed |
description | PURPOSE: To evaluate the value of single-energy metal artifact reduction (SEMAR) algorithm on image quality in patients after complex endovascular aortic repair (EVAR) with fenestrated and branched devices. METHODS: Routine follow-up computed tomography angiography (CTA) examinations were performed between February 2016 and May 2017 in 18 patients who underwent a complex EVAR procedure at our institution. Objective analysis was performed by measuring the standard deviation (SD) of attenuation (Hounsfield Units), and the contrast-to-noise ratio (CNR) in regions of interests in the stented visceral arteries. Subjective analysis of the degree of artifacts and stent visualization was performed independently by two interventional radiologists, blinded to the image reconstruction. RESULTS: The SD of attenuation was significantly lower in all target visceral arteries (p < .001), the celiac artery (p = .002), the superior mesenteric artery (SMA; p = .043), and renal arteries (p < .001) in the CT images with SEMAR reconstruction. The CNR significantly increased in all SEMAR-reconstructed target visceral arteries (overall: p < .001, celiac artery: p = .009; SMA: p = .003; renal arteries: p < .001). The reviewers rated a significantly lower artifact degree in all target vessels (overall: p < .001, celiac artery: p = .001; SMA: p = .008; renal arteries: p < .001) and a significantly improved visualization of the stent patency in all target vessels (overall: p < .001, celiac artery: p = .031; SMA: p = .047; renal arteries: p < .001) in the SEMAR images. Overall preference of both reviewers was in favor of the SEMAR reconstruction in 15/18 cases (83%). CONCLUSION: Reconstruction with SEMAR algorithm significantly improves CTA image quality in patients after complex EVAR. LEVEL OF EVIDENCE: Level 4, Case series. |
format | Online Article Text |
id | pubmed-5758681 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-57586812018-01-22 Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair Ragusi, M. A. A. D. van der Meer, R. W. Joemai, R. M. S. van Schaik, J. van Rijswijk, C. S. P. Cardiovasc Intervent Radiol Technical Note PURPOSE: To evaluate the value of single-energy metal artifact reduction (SEMAR) algorithm on image quality in patients after complex endovascular aortic repair (EVAR) with fenestrated and branched devices. METHODS: Routine follow-up computed tomography angiography (CTA) examinations were performed between February 2016 and May 2017 in 18 patients who underwent a complex EVAR procedure at our institution. Objective analysis was performed by measuring the standard deviation (SD) of attenuation (Hounsfield Units), and the contrast-to-noise ratio (CNR) in regions of interests in the stented visceral arteries. Subjective analysis of the degree of artifacts and stent visualization was performed independently by two interventional radiologists, blinded to the image reconstruction. RESULTS: The SD of attenuation was significantly lower in all target visceral arteries (p < .001), the celiac artery (p = .002), the superior mesenteric artery (SMA; p = .043), and renal arteries (p < .001) in the CT images with SEMAR reconstruction. The CNR significantly increased in all SEMAR-reconstructed target visceral arteries (overall: p < .001, celiac artery: p = .009; SMA: p = .003; renal arteries: p < .001). The reviewers rated a significantly lower artifact degree in all target vessels (overall: p < .001, celiac artery: p = .001; SMA: p = .008; renal arteries: p < .001) and a significantly improved visualization of the stent patency in all target vessels (overall: p < .001, celiac artery: p = .031; SMA: p = .047; renal arteries: p < .001) in the SEMAR images. Overall preference of both reviewers was in favor of the SEMAR reconstruction in 15/18 cases (83%). CONCLUSION: Reconstruction with SEMAR algorithm significantly improves CTA image quality in patients after complex EVAR. LEVEL OF EVIDENCE: Level 4, Case series. Springer US 2017-10-30 2018 /pmc/articles/PMC5758681/ /pubmed/29086057 http://dx.doi.org/10.1007/s00270-017-1812-0 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Technical Note Ragusi, M. A. A. D. van der Meer, R. W. Joemai, R. M. S. van Schaik, J. van Rijswijk, C. S. P. Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair |
title | Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair |
title_full | Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair |
title_fullStr | Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair |
title_full_unstemmed | Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair |
title_short | Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair |
title_sort | evaluation of ct angiography image quality acquired with single-energy metal artifact reduction (semar) algorithm in patients after complex endovascular aortic repair |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5758681/ https://www.ncbi.nlm.nih.gov/pubmed/29086057 http://dx.doi.org/10.1007/s00270-017-1812-0 |
work_keys_str_mv | AT ragusimaad evaluationofctangiographyimagequalityacquiredwithsingleenergymetalartifactreductionsemaralgorithminpatientsaftercomplexendovascularaorticrepair AT vandermeerrw evaluationofctangiographyimagequalityacquiredwithsingleenergymetalartifactreductionsemaralgorithminpatientsaftercomplexendovascularaorticrepair AT joemairms evaluationofctangiographyimagequalityacquiredwithsingleenergymetalartifactreductionsemaralgorithminpatientsaftercomplexendovascularaorticrepair AT vanschaikj evaluationofctangiographyimagequalityacquiredwithsingleenergymetalartifactreductionsemaralgorithminpatientsaftercomplexendovascularaorticrepair AT vanrijswijkcsp evaluationofctangiographyimagequalityacquiredwithsingleenergymetalartifactreductionsemaralgorithminpatientsaftercomplexendovascularaorticrepair |