Development and validation of RP-HPLC method for estimation of eplerenone in spiked human plasma

A rapid and simple high performance liquid chromatography (HPLC) method with a UV detection (241 nm) was developed and validated for estimation of eplerenone from spiked human plasma. The analyte and the internal standard (valdecoxib) were extracted with a mixture of dichloromethane and diethyl ethe...

Descripción completa

Detalles Bibliográficos
Autores principales: Gide, Paraag, Sonawane, Sandeep, Chitnis, Abhishek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760755/
https://www.ncbi.nlm.nih.gov/pubmed/29403773
http://dx.doi.org/10.1016/j.jpha.2012.04.006
Descripción
Sumario:A rapid and simple high performance liquid chromatography (HPLC) method with a UV detection (241 nm) was developed and validated for estimation of eplerenone from spiked human plasma. The analyte and the internal standard (valdecoxib) were extracted with a mixture of dichloromethane and diethyl ether. The chromatographic separation was performed on a HiQSil C-18HS column (250 mm×4.6 mm, 5 μm) with a mobile phase consisting of acetonitrile:water (50:50, v/v) at flow rate of 1 mL/min. The calibration curve was linear in the range 100–3200 ng/mL and the heteroscedasticity was minimized by using weighted least squares regression with weighting factor 1/X.