Cargando…

Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples

A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolys...

Descripción completa

Detalles Bibliográficos
Autores principales: Gerace, E., Salomone, A., Abbadessa, G., Racca, S., Vincenti, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760826/
https://www.ncbi.nlm.nih.gov/pubmed/29403714
http://dx.doi.org/10.1016/j.jpha.2011.09.011
_version_ 1783291443583909888
author Gerace, E.
Salomone, A.
Abbadessa, G.
Racca, S.
Vincenti, M.
author_facet Gerace, E.
Salomone, A.
Abbadessa, G.
Racca, S.
Vincenti, M.
author_sort Gerace, E.
collection PubMed
description A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.
format Online
Article
Text
id pubmed-5760826
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57608262018-02-05 Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples Gerace, E. Salomone, A. Abbadessa, G. Racca, S. Vincenti, M. J Pharm Anal Article A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. Xi'an Jiaotong University 2012-02 2011-10-26 /pmc/articles/PMC5760826/ /pubmed/29403714 http://dx.doi.org/10.1016/j.jpha.2011.09.011 Text en © 2011 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Gerace, E.
Salomone, A.
Abbadessa, G.
Racca, S.
Vincenti, M.
Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples
title Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples
title_full Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples
title_fullStr Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples
title_full_unstemmed Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples
title_short Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples
title_sort rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: method validation and application to real samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760826/
https://www.ncbi.nlm.nih.gov/pubmed/29403714
http://dx.doi.org/10.1016/j.jpha.2011.09.011
work_keys_str_mv AT geracee rapiddeterminationofantiestrogensbygaschromatographymassspectrometryinurinemethodvalidationandapplicationtorealsamples
AT salomonea rapiddeterminationofantiestrogensbygaschromatographymassspectrometryinurinemethodvalidationandapplicationtorealsamples
AT abbadessag rapiddeterminationofantiestrogensbygaschromatographymassspectrometryinurinemethodvalidationandapplicationtorealsamples
AT raccas rapiddeterminationofantiestrogensbygaschromatographymassspectrometryinurinemethodvalidationandapplicationtorealsamples
AT vincentim rapiddeterminationofantiestrogensbygaschromatographymassspectrometryinurinemethodvalidationandapplicationtorealsamples