Cargando…

Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial

BACKGROUND: Peripheral pulmonary lesions (PPLs) pose a diagnostic challenge, and the optimal investigation in many such cases remains unclear. Computed tomography (CT)-guided percutaneous needle biopsy (CT-PNB) has been the modality of choice for such lesions with a high diagnostic accuracy but with...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Ayush, Suri, Jagdish Chander, Bhattacharya, Dipak, Sen, Manas Kamal, Chakrabarti, Shibdas, Singh, Abhijeet, Adhikari, Tulsi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760880/
https://www.ncbi.nlm.nih.gov/pubmed/29319027
http://dx.doi.org/10.4103/lungindia.lungindia_208_17
_version_ 1783291456039944192
author Gupta, Ayush
Suri, Jagdish Chander
Bhattacharya, Dipak
Sen, Manas Kamal
Chakrabarti, Shibdas
Singh, Abhijeet
Adhikari, Tulsi
author_facet Gupta, Ayush
Suri, Jagdish Chander
Bhattacharya, Dipak
Sen, Manas Kamal
Chakrabarti, Shibdas
Singh, Abhijeet
Adhikari, Tulsi
author_sort Gupta, Ayush
collection PubMed
description BACKGROUND: Peripheral pulmonary lesions (PPLs) pose a diagnostic challenge, and the optimal investigation in many such cases remains unclear. Computed tomography (CT)-guided percutaneous needle biopsy (CT-PNB) has been the modality of choice for such lesions with a high diagnostic accuracy but with high rates of pneumothorax. Endobronchial ultrasound (EBUS) with a radial probe is an alternate diagnostic modality with increased diagnostic yield of bronchoscopy in the evaluation of PPL. We conducted a randomized controlled trial comparing the diagnostic accuracy and complication rates of radial EBUS with CT-guided lung biopsy for the evaluation of PPL. METHODS: Fifty patients with PPL surrounded by lung parenchyma on all sides were randomly assigned to either radial EBUS or CT-PNB group (25 each). RESULTS: Both groups had similar clinicoradiologic characteristics. The diagnostic accuracy of radial EBUS was comparable to CT-PNB with no statistically significant difference (72 vs. 84%; P = 0.306). However, the yield was significantly lower in right upper lobe lesions (20% vs. 83.3%; P = 0.03). CT-PNB group had significantly higher pneumothorax rates than radial EBUS (20% vs. 0%; P = 0.03). The lesions that were more than 2 cm, those with ultrasound feature of continuous hyperechoic margin around the lesion (P = 0.007), and the position of the ultrasound probe within the lesion (P < 0.001) were associated with a higher diagnostic yield with radial EBUS. CONCLUSION: Our findings suggest that radial EBUS is a safer investigation than CT-PNB with a comparable diagnostic accuracy for PPL not abutting the chest wall (CTRI/2017/02/007762).
format Online
Article
Text
id pubmed-5760880
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-57608802018-02-07 Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial Gupta, Ayush Suri, Jagdish Chander Bhattacharya, Dipak Sen, Manas Kamal Chakrabarti, Shibdas Singh, Abhijeet Adhikari, Tulsi Lung India Original Article BACKGROUND: Peripheral pulmonary lesions (PPLs) pose a diagnostic challenge, and the optimal investigation in many such cases remains unclear. Computed tomography (CT)-guided percutaneous needle biopsy (CT-PNB) has been the modality of choice for such lesions with a high diagnostic accuracy but with high rates of pneumothorax. Endobronchial ultrasound (EBUS) with a radial probe is an alternate diagnostic modality with increased diagnostic yield of bronchoscopy in the evaluation of PPL. We conducted a randomized controlled trial comparing the diagnostic accuracy and complication rates of radial EBUS with CT-guided lung biopsy for the evaluation of PPL. METHODS: Fifty patients with PPL surrounded by lung parenchyma on all sides were randomly assigned to either radial EBUS or CT-PNB group (25 each). RESULTS: Both groups had similar clinicoradiologic characteristics. The diagnostic accuracy of radial EBUS was comparable to CT-PNB with no statistically significant difference (72 vs. 84%; P = 0.306). However, the yield was significantly lower in right upper lobe lesions (20% vs. 83.3%; P = 0.03). CT-PNB group had significantly higher pneumothorax rates than radial EBUS (20% vs. 0%; P = 0.03). The lesions that were more than 2 cm, those with ultrasound feature of continuous hyperechoic margin around the lesion (P = 0.007), and the position of the ultrasound probe within the lesion (P < 0.001) were associated with a higher diagnostic yield with radial EBUS. CONCLUSION: Our findings suggest that radial EBUS is a safer investigation than CT-PNB with a comparable diagnostic accuracy for PPL not abutting the chest wall (CTRI/2017/02/007762). Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5760880/ /pubmed/29319027 http://dx.doi.org/10.4103/lungindia.lungindia_208_17 Text en Copyright: © 2017 Indian Chest Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Gupta, Ayush
Suri, Jagdish Chander
Bhattacharya, Dipak
Sen, Manas Kamal
Chakrabarti, Shibdas
Singh, Abhijeet
Adhikari, Tulsi
Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial
title Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial
title_full Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial
title_fullStr Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial
title_full_unstemmed Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial
title_short Comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: A randomized controlled trial
title_sort comparison of diagnostic yield and safety profile of radial endobronchial ultrasound-guided bronchoscopic lung biopsy with computed tomography-guided percutaneous needle biopsy in evaluation of peripheral pulmonary lesions: a randomized controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760880/
https://www.ncbi.nlm.nih.gov/pubmed/29319027
http://dx.doi.org/10.4103/lungindia.lungindia_208_17
work_keys_str_mv AT guptaayush comparisonofdiagnosticyieldandsafetyprofileofradialendobronchialultrasoundguidedbronchoscopiclungbiopsywithcomputedtomographyguidedpercutaneousneedlebiopsyinevaluationofperipheralpulmonarylesionsarandomizedcontrolledtrial
AT surijagdishchander comparisonofdiagnosticyieldandsafetyprofileofradialendobronchialultrasoundguidedbronchoscopiclungbiopsywithcomputedtomographyguidedpercutaneousneedlebiopsyinevaluationofperipheralpulmonarylesionsarandomizedcontrolledtrial
AT bhattacharyadipak comparisonofdiagnosticyieldandsafetyprofileofradialendobronchialultrasoundguidedbronchoscopiclungbiopsywithcomputedtomographyguidedpercutaneousneedlebiopsyinevaluationofperipheralpulmonarylesionsarandomizedcontrolledtrial
AT senmanaskamal comparisonofdiagnosticyieldandsafetyprofileofradialendobronchialultrasoundguidedbronchoscopiclungbiopsywithcomputedtomographyguidedpercutaneousneedlebiopsyinevaluationofperipheralpulmonarylesionsarandomizedcontrolledtrial
AT chakrabartishibdas comparisonofdiagnosticyieldandsafetyprofileofradialendobronchialultrasoundguidedbronchoscopiclungbiopsywithcomputedtomographyguidedpercutaneousneedlebiopsyinevaluationofperipheralpulmonarylesionsarandomizedcontrolledtrial
AT singhabhijeet comparisonofdiagnosticyieldandsafetyprofileofradialendobronchialultrasoundguidedbronchoscopiclungbiopsywithcomputedtomographyguidedpercutaneousneedlebiopsyinevaluationofperipheralpulmonarylesionsarandomizedcontrolledtrial
AT adhikaritulsi comparisonofdiagnosticyieldandsafetyprofileofradialendobronchialultrasoundguidedbronchoscopiclungbiopsywithcomputedtomographyguidedpercutaneousneedlebiopsyinevaluationofperipheralpulmonarylesionsarandomizedcontrolledtrial