Cargando…

Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations

A new rapid and sensitive high performance liquid chromatography (HPLC) method has been developed for the simultaneous determination of atorvastatin—an antihyperlipidemic drug along with most commonly prescribed drugs (antihyperlipidemic, antihypertensive, antidiabetic, antithrombotic) in bulk and m...

Descripción completa

Detalles Bibliográficos
Autores principales: Talluri, M.V.N. Kumar, Kalyankar, Anitha, Ragampeta, Srinivas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760911/
https://www.ncbi.nlm.nih.gov/pubmed/29403755
http://dx.doi.org/10.1016/j.jpha.2012.02.006
_version_ 1783291463582351360
author Talluri, M.V.N. Kumar
Kalyankar, Anitha
Ragampeta, Srinivas
author_facet Talluri, M.V.N. Kumar
Kalyankar, Anitha
Ragampeta, Srinivas
author_sort Talluri, M.V.N. Kumar
collection PubMed
description A new rapid and sensitive high performance liquid chromatography (HPLC) method has been developed for the simultaneous determination of atorvastatin—an antihyperlipidemic drug along with most commonly prescribed drugs (antihyperlipidemic, antihypertensive, antidiabetic, antithrombotic) in bulk and marketed combined formulations. The chromatographic separation was carried out by gradient elution mode with acetonitrile as organic modifier and 0.1% triethylamine acetate (TEAA) buffer pH 5 at a flow rate of 1 mL/min and a diode array detector at wavelength 230 nm was employed for detection of the analytes. Calibration curves were linear in the range of 5–150 μg/mL for all the drugs with correlation coefficients of determination (r(2) values)≥0.999. Limits of detection (LODs) and Limits of quantification (LOQs) ranged from 0.1 to 0.27 μg/mL and 0.3 to 0.89 μg/mL respectively. Intra-day and inter-day precision was studied at three concentration levels (20, 60 and 100 μg/mL). The intra-day and inter-day RSD for all compounds was less than 2.0%. The accuracy for all compounds was found to be between 98% and 102%. Thus, the performance of the method described allows its use in quantification of atorvastatin along with 9 most commonly prescribed drugs available in market as atorvastatin combined dosage forms.
format Online
Article
Text
id pubmed-5760911
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57609112018-02-05 Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations Talluri, M.V.N. Kumar Kalyankar, Anitha Ragampeta, Srinivas J Pharm Anal Article A new rapid and sensitive high performance liquid chromatography (HPLC) method has been developed for the simultaneous determination of atorvastatin—an antihyperlipidemic drug along with most commonly prescribed drugs (antihyperlipidemic, antihypertensive, antidiabetic, antithrombotic) in bulk and marketed combined formulations. The chromatographic separation was carried out by gradient elution mode with acetonitrile as organic modifier and 0.1% triethylamine acetate (TEAA) buffer pH 5 at a flow rate of 1 mL/min and a diode array detector at wavelength 230 nm was employed for detection of the analytes. Calibration curves were linear in the range of 5–150 μg/mL for all the drugs with correlation coefficients of determination (r(2) values)≥0.999. Limits of detection (LODs) and Limits of quantification (LOQs) ranged from 0.1 to 0.27 μg/mL and 0.3 to 0.89 μg/mL respectively. Intra-day and inter-day precision was studied at three concentration levels (20, 60 and 100 μg/mL). The intra-day and inter-day RSD for all compounds was less than 2.0%. The accuracy for all compounds was found to be between 98% and 102%. Thus, the performance of the method described allows its use in quantification of atorvastatin along with 9 most commonly prescribed drugs available in market as atorvastatin combined dosage forms. Xi'an Jiaotong University 2012-08 2012-03-13 /pmc/articles/PMC5760911/ /pubmed/29403755 http://dx.doi.org/10.1016/j.jpha.2012.02.006 Text en © 2012 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Talluri, M.V.N. Kumar
Kalyankar, Anitha
Ragampeta, Srinivas
Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations
title Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations
title_full Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations
title_fullStr Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations
title_full_unstemmed Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations
title_short Synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by RP-LC for determination in combined formulations
title_sort synchronized separation of atorvastatin—an antihyperlipidemic drug with antihypertensive, antidiabetic, antithrombotic drugs by rp-lc for determination in combined formulations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760911/
https://www.ncbi.nlm.nih.gov/pubmed/29403755
http://dx.doi.org/10.1016/j.jpha.2012.02.006
work_keys_str_mv AT tallurimvnkumar synchronizedseparationofatorvastatinanantihyperlipidemicdrugwithantihypertensiveantidiabeticantithromboticdrugsbyrplcfordeterminationincombinedformulations
AT kalyankaranitha synchronizedseparationofatorvastatinanantihyperlipidemicdrugwithantihypertensiveantidiabeticantithromboticdrugsbyrplcfordeterminationincombinedformulations
AT ragampetasrinivas synchronizedseparationofatorvastatinanantihyperlipidemicdrugwithantihypertensiveantidiabeticantithromboticdrugsbyrplcfordeterminationincombinedformulations