Cargando…

Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal stand...

Descripción completa

Detalles Bibliográficos
Autores principales: Upadhyay, Vivek, Trivedi, Vikas, Shah, Gaurang, Yadav, Manish, Shrivastav, Pranav S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5761118/
https://www.ncbi.nlm.nih.gov/pubmed/29403884
http://dx.doi.org/10.1016/j.jpha.2013.06.001
_version_ 1783291503752249344
author Upadhyay, Vivek
Trivedi, Vikas
Shah, Gaurang
Yadav, Manish
Shrivastav, Pranav S.
author_facet Upadhyay, Vivek
Trivedi, Vikas
Shah, Gaurang
Yadav, Manish
Shrivastav, Pranav S.
author_sort Upadhyay, Vivek
collection PubMed
description A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 µL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100 mm×2.1 mm, 1.7 µm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was >95%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.
format Online
Article
Text
id pubmed-5761118
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57611182018-02-05 Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry Upadhyay, Vivek Trivedi, Vikas Shah, Gaurang Yadav, Manish Shrivastav, Pranav S. J Pharm Anal Original Article A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 µL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100 mm×2.1 mm, 1.7 µm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was >95%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects. Xi'an Jiaotong University 2014-06 2013-06-12 /pmc/articles/PMC5761118/ /pubmed/29403884 http://dx.doi.org/10.1016/j.jpha.2013.06.001 Text en © 2013 Xi’an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Original Article
Upadhyay, Vivek
Trivedi, Vikas
Shah, Gaurang
Yadav, Manish
Shrivastav, Pranav S.
Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry
title Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry
title_full Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry
title_fullStr Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry
title_full_unstemmed Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry
title_short Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry
title_sort determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5761118/
https://www.ncbi.nlm.nih.gov/pubmed/29403884
http://dx.doi.org/10.1016/j.jpha.2013.06.001
work_keys_str_mv AT upadhyayvivek determinationofmycophenolicacidinhumanplasmabyultraperformanceliquidchromatographytandemmassspectrometry
AT trivedivikas determinationofmycophenolicacidinhumanplasmabyultraperformanceliquidchromatographytandemmassspectrometry
AT shahgaurang determinationofmycophenolicacidinhumanplasmabyultraperformanceliquidchromatographytandemmassspectrometry
AT yadavmanish determinationofmycophenolicacidinhumanplasmabyultraperformanceliquidchromatographytandemmassspectrometry
AT shrivastavpranavs determinationofmycophenolicacidinhumanplasmabyultraperformanceliquidchromatographytandemmassspectrometry