Cargando…

Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy

Deformable image registration is a powerful tool for mapping information, such as radiation therapy dose calculations, from one computed tomography image to another. However, deformable image registration is susceptible to mapping errors. Recently, an automated deformable image registration evaluati...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Hojin, Chen, Josephine, Phillips, Justin, Pukala, Jason, Yom, Sue S., Kirby, Neil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762045/
https://www.ncbi.nlm.nih.gov/pubmed/28490254
http://dx.doi.org/10.1177/1533034617708076
_version_ 1783291623890747392
author Kim, Hojin
Chen, Josephine
Phillips, Justin
Pukala, Jason
Yom, Sue S.
Kirby, Neil
author_facet Kim, Hojin
Chen, Josephine
Phillips, Justin
Pukala, Jason
Yom, Sue S.
Kirby, Neil
author_sort Kim, Hojin
collection PubMed
description Deformable image registration is a powerful tool for mapping information, such as radiation therapy dose calculations, from one computed tomography image to another. However, deformable image registration is susceptible to mapping errors. Recently, an automated deformable image registration evaluation of confidence tool was proposed to predict voxel-specific deformable image registration dose mapping errors on a patient-by-patient basis. The purpose of this work is to conduct an extensive analysis of automated deformable image registration evaluation of confidence tool to show its effectiveness in estimating dose mapping errors. The proposed format of automated deformable image registration evaluation of confidence tool utilizes 4 simulated patient deformations (3 B-spline-based deformations and 1 rigid transformation) to predict the uncertainty in a deformable image registration algorithm’s performance. This workflow is validated for 2 DIR algorithms (B-spline multipass from Velocity and Plastimatch) with 1 physical and 11 virtual phantoms, which have known ground-truth deformations, and with 3 pairs of real patient lung images, which have several hundred identified landmarks. The true dose mapping error distributions closely followed the Student t distributions predicted by automated deformable image registration evaluation of confidence tool for the validation tests: on average, the automated deformable image registration evaluation of confidence tool–produced confidence levels of 50%, 68%, and 95% contained 48.8%, 66.3%, and 93.8% and 50.1%, 67.6%, and 93.8% of the actual errors from Velocity and Plastimatch, respectively. Despite the sparsity of landmark points, the observed error distribution from the 3 lung patient data sets also followed the expected error distribution. The dose error distributions from automated deformable image registration evaluation of confidence tool also demonstrate good resemblance to the true dose error distributions. Automated deformable image registration evaluation of confidence tool was also found to produce accurate confidence intervals for the dose–volume histograms of the deformed dose.
format Online
Article
Text
id pubmed-5762045
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-57620452018-01-17 Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy Kim, Hojin Chen, Josephine Phillips, Justin Pukala, Jason Yom, Sue S. Kirby, Neil Technol Cancer Res Treat Original Articles Deformable image registration is a powerful tool for mapping information, such as radiation therapy dose calculations, from one computed tomography image to another. However, deformable image registration is susceptible to mapping errors. Recently, an automated deformable image registration evaluation of confidence tool was proposed to predict voxel-specific deformable image registration dose mapping errors on a patient-by-patient basis. The purpose of this work is to conduct an extensive analysis of automated deformable image registration evaluation of confidence tool to show its effectiveness in estimating dose mapping errors. The proposed format of automated deformable image registration evaluation of confidence tool utilizes 4 simulated patient deformations (3 B-spline-based deformations and 1 rigid transformation) to predict the uncertainty in a deformable image registration algorithm’s performance. This workflow is validated for 2 DIR algorithms (B-spline multipass from Velocity and Plastimatch) with 1 physical and 11 virtual phantoms, which have known ground-truth deformations, and with 3 pairs of real patient lung images, which have several hundred identified landmarks. The true dose mapping error distributions closely followed the Student t distributions predicted by automated deformable image registration evaluation of confidence tool for the validation tests: on average, the automated deformable image registration evaluation of confidence tool–produced confidence levels of 50%, 68%, and 95% contained 48.8%, 66.3%, and 93.8% and 50.1%, 67.6%, and 93.8% of the actual errors from Velocity and Plastimatch, respectively. Despite the sparsity of landmark points, the observed error distribution from the 3 lung patient data sets also followed the expected error distribution. The dose error distributions from automated deformable image registration evaluation of confidence tool also demonstrate good resemblance to the true dose error distributions. Automated deformable image registration evaluation of confidence tool was also found to produce accurate confidence intervals for the dose–volume histograms of the deformed dose. SAGE Publications 2017-05-11 2017-12 /pmc/articles/PMC5762045/ /pubmed/28490254 http://dx.doi.org/10.1177/1533034617708076 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Kim, Hojin
Chen, Josephine
Phillips, Justin
Pukala, Jason
Yom, Sue S.
Kirby, Neil
Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
title Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
title_full Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
title_fullStr Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
title_full_unstemmed Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
title_short Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
title_sort validating dose uncertainty estimates produced by autodirect: an automated program to evaluate deformable image registration accuracy
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762045/
https://www.ncbi.nlm.nih.gov/pubmed/28490254
http://dx.doi.org/10.1177/1533034617708076
work_keys_str_mv AT kimhojin validatingdoseuncertaintyestimatesproducedbyautodirectanautomatedprogramtoevaluatedeformableimageregistrationaccuracy
AT chenjosephine validatingdoseuncertaintyestimatesproducedbyautodirectanautomatedprogramtoevaluatedeformableimageregistrationaccuracy
AT phillipsjustin validatingdoseuncertaintyestimatesproducedbyautodirectanautomatedprogramtoevaluatedeformableimageregistrationaccuracy
AT pukalajason validatingdoseuncertaintyestimatesproducedbyautodirectanautomatedprogramtoevaluatedeformableimageregistrationaccuracy
AT yomsues validatingdoseuncertaintyestimatesproducedbyautodirectanautomatedprogramtoevaluatedeformableimageregistrationaccuracy
AT kirbyneil validatingdoseuncertaintyestimatesproducedbyautodirectanautomatedprogramtoevaluatedeformableimageregistrationaccuracy