Cargando…
Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis
Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762064/ https://www.ncbi.nlm.nih.gov/pubmed/28705082 http://dx.doi.org/10.1177/1533034617718961 |
_version_ | 1783291628225560576 |
---|---|
author | Snider, James W. Mutaf, Yildirim Nichols, Elizabeth Hall, Andrea Vadnais, Patrick Regine, William F. Feigenberg, Steven J. |
author_facet | Snider, James W. Mutaf, Yildirim Nichols, Elizabeth Hall, Andrea Vadnais, Patrick Regine, William F. Feigenberg, Steven J. |
author_sort | Snider, James W. |
collection | PubMed |
description | Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved with the device and intensity-modulated radiation therapy accelerated partial breast irradiation. Nine patients underwent computed tomography simulation in the prone position using device-specific immobilization on an institutional review board–approved protocol. Accelerated partial breast irradiation target volumes (planning target volume_10mm) were created per the National Surgical Adjuvant Breast and Bowel Project B-39 protocol. Additional breast stereotactic radiotherapy volumes using smaller margins (planning target volume_3mm) were created based on improved immobilization. Intensity-modulated radiation therapy and breast stereotactic radiotherapy accelerated partial breast irradiation plans were separately generated for appropriate volumes. Plans were evaluated based on established dosimetric surrogates of poor cosmetic outcomes. Wilcoxon rank sum tests were utilized to contrast volumes of critical structures receiving a percentage of total dose (Vx). The breast stereotactic radiotherapy device consistently reduced dose to all normal structures with equivalent target coverage. The ipsilateral breast V20-100 was significantly reduced (P < .05) using planning target volume_10mm, with substantial further reductions when targeting planning target volume_3mm. Doses to the chest wall, ipsilateral lung, and breast skin were also significantly lessened. The breast stereotactic radiotherapy device’s uniform dosimetric improvements over intensity-modulated accelerated partial breast irradiation in this series indicate a potential to improve outcomes. Clinical trials investigating this benefit have begun accrual. |
format | Online Article Text |
id | pubmed-5762064 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-57620642018-01-17 Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis Snider, James W. Mutaf, Yildirim Nichols, Elizabeth Hall, Andrea Vadnais, Patrick Regine, William F. Feigenberg, Steven J. Technol Cancer Res Treat Original Articles Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved with the device and intensity-modulated radiation therapy accelerated partial breast irradiation. Nine patients underwent computed tomography simulation in the prone position using device-specific immobilization on an institutional review board–approved protocol. Accelerated partial breast irradiation target volumes (planning target volume_10mm) were created per the National Surgical Adjuvant Breast and Bowel Project B-39 protocol. Additional breast stereotactic radiotherapy volumes using smaller margins (planning target volume_3mm) were created based on improved immobilization. Intensity-modulated radiation therapy and breast stereotactic radiotherapy accelerated partial breast irradiation plans were separately generated for appropriate volumes. Plans were evaluated based on established dosimetric surrogates of poor cosmetic outcomes. Wilcoxon rank sum tests were utilized to contrast volumes of critical structures receiving a percentage of total dose (Vx). The breast stereotactic radiotherapy device consistently reduced dose to all normal structures with equivalent target coverage. The ipsilateral breast V20-100 was significantly reduced (P < .05) using planning target volume_10mm, with substantial further reductions when targeting planning target volume_3mm. Doses to the chest wall, ipsilateral lung, and breast skin were also significantly lessened. The breast stereotactic radiotherapy device’s uniform dosimetric improvements over intensity-modulated accelerated partial breast irradiation in this series indicate a potential to improve outcomes. Clinical trials investigating this benefit have begun accrual. SAGE Publications 2017-07-14 2017-12 /pmc/articles/PMC5762064/ /pubmed/28705082 http://dx.doi.org/10.1177/1533034617718961 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (http://www.creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Articles Snider, James W. Mutaf, Yildirim Nichols, Elizabeth Hall, Andrea Vadnais, Patrick Regine, William F. Feigenberg, Steven J. Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis |
title | Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis |
title_full | Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis |
title_fullStr | Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis |
title_full_unstemmed | Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis |
title_short | Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis |
title_sort | projected improvements in accelerated partial breast irradiation using a novel breast stereotactic radiotherapy device: a dosimetric analysis |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762064/ https://www.ncbi.nlm.nih.gov/pubmed/28705082 http://dx.doi.org/10.1177/1533034617718961 |
work_keys_str_mv | AT sniderjamesw projectedimprovementsinacceleratedpartialbreastirradiationusinganovelbreaststereotacticradiotherapydeviceadosimetricanalysis AT mutafyildirim projectedimprovementsinacceleratedpartialbreastirradiationusinganovelbreaststereotacticradiotherapydeviceadosimetricanalysis AT nicholselizabeth projectedimprovementsinacceleratedpartialbreastirradiationusinganovelbreaststereotacticradiotherapydeviceadosimetricanalysis AT hallandrea projectedimprovementsinacceleratedpartialbreastirradiationusinganovelbreaststereotacticradiotherapydeviceadosimetricanalysis AT vadnaispatrick projectedimprovementsinacceleratedpartialbreastirradiationusinganovelbreaststereotacticradiotherapydeviceadosimetricanalysis AT reginewilliamf projectedimprovementsinacceleratedpartialbreastirradiationusinganovelbreaststereotacticradiotherapydeviceadosimetricanalysis AT feigenbergstevenj projectedimprovementsinacceleratedpartialbreastirradiationusinganovelbreaststereotacticradiotherapydeviceadosimetricanalysis |