Cargando…

Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block

The Micro-Electrode Array (MEA) device enables high-throughput electrophysiology measurements that are less labor-intensive than patch-clamp based techniques. Combined with human-induced pluripotent stem cells cardiomyocytes (hiPSC-CM), it represents a new and promising paradigm for automated and ac...

Descripción completa

Detalles Bibliográficos
Autores principales: Tixier, Eliott, Raphel, Fabien, Lombardi, Damiano, Gerbeau, Jean-Frédéric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762138/
https://www.ncbi.nlm.nih.gov/pubmed/29354067
http://dx.doi.org/10.3389/fphys.2017.01096
_version_ 1783291636787183616
author Tixier, Eliott
Raphel, Fabien
Lombardi, Damiano
Gerbeau, Jean-Frédéric
author_facet Tixier, Eliott
Raphel, Fabien
Lombardi, Damiano
Gerbeau, Jean-Frédéric
author_sort Tixier, Eliott
collection PubMed
description The Micro-Electrode Array (MEA) device enables high-throughput electrophysiology measurements that are less labor-intensive than patch-clamp based techniques. Combined with human-induced pluripotent stem cells cardiomyocytes (hiPSC-CM), it represents a new and promising paradigm for automated and accurate in vitro drug safety evaluation. In this article, the following question is addressed: which features of the MEA signals should be measured to better classify the effects of drugs? A framework for the classification of drugs using MEA measurements is proposed. The classification is based on the ion channels blockades induced by the drugs. It relies on an in silico electrophysiology model of the MEA, a feature selection algorithm and automatic classification tools. An in silico model of the MEA is developed and is used to generate synthetic measurements. An algorithm that extracts MEA measurements features designed to perform well in a classification context is described. These features are called composite biomarkers. A state-of-the-art machine learning program is used to carry out the classification of drugs using experimental MEA measurements. The experiments are carried out using five different drugs: mexiletine, flecainide, diltiazem, moxifloxacin, and dofetilide. We show that the composite biomarkers outperform the classical ones in different classification scenarios. We show that using both synthetic and experimental MEA measurements improves the robustness of the composite biomarkers and that the classification scores are increased.
format Online
Article
Text
id pubmed-5762138
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-57621382018-01-19 Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block Tixier, Eliott Raphel, Fabien Lombardi, Damiano Gerbeau, Jean-Frédéric Front Physiol Physiology The Micro-Electrode Array (MEA) device enables high-throughput electrophysiology measurements that are less labor-intensive than patch-clamp based techniques. Combined with human-induced pluripotent stem cells cardiomyocytes (hiPSC-CM), it represents a new and promising paradigm for automated and accurate in vitro drug safety evaluation. In this article, the following question is addressed: which features of the MEA signals should be measured to better classify the effects of drugs? A framework for the classification of drugs using MEA measurements is proposed. The classification is based on the ion channels blockades induced by the drugs. It relies on an in silico electrophysiology model of the MEA, a feature selection algorithm and automatic classification tools. An in silico model of the MEA is developed and is used to generate synthetic measurements. An algorithm that extracts MEA measurements features designed to perform well in a classification context is described. These features are called composite biomarkers. A state-of-the-art machine learning program is used to carry out the classification of drugs using experimental MEA measurements. The experiments are carried out using five different drugs: mexiletine, flecainide, diltiazem, moxifloxacin, and dofetilide. We show that the composite biomarkers outperform the classical ones in different classification scenarios. We show that using both synthetic and experimental MEA measurements improves the robustness of the composite biomarkers and that the classification scores are increased. Frontiers Media S.A. 2018-01-04 /pmc/articles/PMC5762138/ /pubmed/29354067 http://dx.doi.org/10.3389/fphys.2017.01096 Text en Copyright © 2018 Tixier, Raphel, Lombardi and Gerbeau. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Tixier, Eliott
Raphel, Fabien
Lombardi, Damiano
Gerbeau, Jean-Frédéric
Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
title Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
title_full Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
title_fullStr Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
title_full_unstemmed Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
title_short Composite Biomarkers Derived from Micro-Electrode Array Measurements and Computer Simulations Improve the Classification of Drug-Induced Channel Block
title_sort composite biomarkers derived from micro-electrode array measurements and computer simulations improve the classification of drug-induced channel block
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762138/
https://www.ncbi.nlm.nih.gov/pubmed/29354067
http://dx.doi.org/10.3389/fphys.2017.01096
work_keys_str_mv AT tixiereliott compositebiomarkersderivedfrommicroelectrodearraymeasurementsandcomputersimulationsimprovetheclassificationofdruginducedchannelblock
AT raphelfabien compositebiomarkersderivedfrommicroelectrodearraymeasurementsandcomputersimulationsimprovetheclassificationofdruginducedchannelblock
AT lombardidamiano compositebiomarkersderivedfrommicroelectrodearraymeasurementsandcomputersimulationsimprovetheclassificationofdruginducedchannelblock
AT gerbeaujeanfrederic compositebiomarkersderivedfrommicroelectrodearraymeasurementsandcomputersimulationsimprovetheclassificationofdruginducedchannelblock