Cargando…
Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
A multi-walled carbon nanotube (MWCNT)-cetyltrimethylammonium bromide (CTAB) surfactant composite modified glassy carbon electrode (GCE) was developed as a novel system for the determination of 4-aminoantipyrine(AAP). The oxidation process was irreversible over the pH range studied and exhibited a d...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762206/ https://www.ncbi.nlm.nih.gov/pubmed/29403936 http://dx.doi.org/10.1016/j.jpha.2015.01.001 |
_version_ | 1783291643390066688 |
---|---|
author | Gowda, Jayant I. Buddanavar, Arunkumar T. Nandibewoor, Sharanappa T. |
author_facet | Gowda, Jayant I. Buddanavar, Arunkumar T. Nandibewoor, Sharanappa T. |
author_sort | Gowda, Jayant I. |
collection | PubMed |
description | A multi-walled carbon nanotube (MWCNT)-cetyltrimethylammonium bromide (CTAB) surfactant composite modified glassy carbon electrode (GCE) was developed as a novel system for the determination of 4-aminoantipyrine(AAP). The oxidation process was irreversible over the pH range studied and exhibited a diffusion controlled behavior. All experimental parameters were optimized. The combination of MWCNT-CTAB endows the biosensor with large surface area, good biological compatibility, electricity and stability, high selectivity and sensitivity. MWCNT-CTAB/GCE electrode gave a linear response for AAP from 5.0×10(−9) to 4.0×10(−8) M with a detection limit of 1.63×10(−10) M. The modified electrode showed good selectivity against interfering species and also exhibited good reproducibility. The present electrochemical sensor based on the MWCNT-CTAB/GCE electrode was applied to the determination of AAP in real samples. |
format | Online Article Text |
id | pubmed-5762206 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-57622062018-02-05 Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() Gowda, Jayant I. Buddanavar, Arunkumar T. Nandibewoor, Sharanappa T. J Pharm Anal Original Article A multi-walled carbon nanotube (MWCNT)-cetyltrimethylammonium bromide (CTAB) surfactant composite modified glassy carbon electrode (GCE) was developed as a novel system for the determination of 4-aminoantipyrine(AAP). The oxidation process was irreversible over the pH range studied and exhibited a diffusion controlled behavior. All experimental parameters were optimized. The combination of MWCNT-CTAB endows the biosensor with large surface area, good biological compatibility, electricity and stability, high selectivity and sensitivity. MWCNT-CTAB/GCE electrode gave a linear response for AAP from 5.0×10(−9) to 4.0×10(−8) M with a detection limit of 1.63×10(−10) M. The modified electrode showed good selectivity against interfering species and also exhibited good reproducibility. The present electrochemical sensor based on the MWCNT-CTAB/GCE electrode was applied to the determination of AAP in real samples. Xi'an Jiaotong University 2015-08 2015-01-17 /pmc/articles/PMC5762206/ /pubmed/29403936 http://dx.doi.org/10.1016/j.jpha.2015.01.001 Text en © 2015 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Gowda, Jayant I. Buddanavar, Arunkumar T. Nandibewoor, Sharanappa T. Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() |
title | Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() |
title_full | Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() |
title_fullStr | Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() |
title_full_unstemmed | Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() |
title_short | Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() |
title_sort | fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762206/ https://www.ncbi.nlm.nih.gov/pubmed/29403936 http://dx.doi.org/10.1016/j.jpha.2015.01.001 |
work_keys_str_mv | AT gowdajayanti fabricationofmultiwalledcarbonnanotubesurfactantmodifiedsensorforthedirectdeterminationoftoxicdrug4aminoantipyrine AT buddanavararunkumart fabricationofmultiwalledcarbonnanotubesurfactantmodifiedsensorforthedirectdeterminationoftoxicdrug4aminoantipyrine AT nandibewoorsharanappat fabricationofmultiwalledcarbonnanotubesurfactantmodifiedsensorforthedirectdeterminationoftoxicdrug4aminoantipyrine |