Cargando…

Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()

A multi-walled carbon nanotube (MWCNT)-cetyltrimethylammonium bromide (CTAB) surfactant composite modified glassy carbon electrode (GCE) was developed as a novel system for the determination of 4-aminoantipyrine(AAP). The oxidation process was irreversible over the pH range studied and exhibited a d...

Descripción completa

Detalles Bibliográficos
Autores principales: Gowda, Jayant I., Buddanavar, Arunkumar T., Nandibewoor, Sharanappa T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762206/
https://www.ncbi.nlm.nih.gov/pubmed/29403936
http://dx.doi.org/10.1016/j.jpha.2015.01.001
_version_ 1783291643390066688
author Gowda, Jayant I.
Buddanavar, Arunkumar T.
Nandibewoor, Sharanappa T.
author_facet Gowda, Jayant I.
Buddanavar, Arunkumar T.
Nandibewoor, Sharanappa T.
author_sort Gowda, Jayant I.
collection PubMed
description A multi-walled carbon nanotube (MWCNT)-cetyltrimethylammonium bromide (CTAB) surfactant composite modified glassy carbon electrode (GCE) was developed as a novel system for the determination of 4-aminoantipyrine(AAP). The oxidation process was irreversible over the pH range studied and exhibited a diffusion controlled behavior. All experimental parameters were optimized. The combination of MWCNT-CTAB endows the biosensor with large surface area, good biological compatibility, electricity and stability, high selectivity and sensitivity. MWCNT-CTAB/GCE electrode gave a linear response for AAP from 5.0×10(−9) to 4.0×10(−8) M with a detection limit of 1.63×10(−10) M. The modified electrode showed good selectivity against interfering species and also exhibited good reproducibility. The present electrochemical sensor based on the MWCNT-CTAB/GCE electrode was applied to the determination of AAP in real samples.
format Online
Article
Text
id pubmed-5762206
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57622062018-02-05 Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine() Gowda, Jayant I. Buddanavar, Arunkumar T. Nandibewoor, Sharanappa T. J Pharm Anal Original Article A multi-walled carbon nanotube (MWCNT)-cetyltrimethylammonium bromide (CTAB) surfactant composite modified glassy carbon electrode (GCE) was developed as a novel system for the determination of 4-aminoantipyrine(AAP). The oxidation process was irreversible over the pH range studied and exhibited a diffusion controlled behavior. All experimental parameters were optimized. The combination of MWCNT-CTAB endows the biosensor with large surface area, good biological compatibility, electricity and stability, high selectivity and sensitivity. MWCNT-CTAB/GCE electrode gave a linear response for AAP from 5.0×10(−9) to 4.0×10(−8) M with a detection limit of 1.63×10(−10) M. The modified electrode showed good selectivity against interfering species and also exhibited good reproducibility. The present electrochemical sensor based on the MWCNT-CTAB/GCE electrode was applied to the determination of AAP in real samples. Xi'an Jiaotong University 2015-08 2015-01-17 /pmc/articles/PMC5762206/ /pubmed/29403936 http://dx.doi.org/10.1016/j.jpha.2015.01.001 Text en © 2015 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Gowda, Jayant I.
Buddanavar, Arunkumar T.
Nandibewoor, Sharanappa T.
Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
title Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
title_full Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
title_fullStr Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
title_full_unstemmed Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
title_short Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
title_sort fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine()
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762206/
https://www.ncbi.nlm.nih.gov/pubmed/29403936
http://dx.doi.org/10.1016/j.jpha.2015.01.001
work_keys_str_mv AT gowdajayanti fabricationofmultiwalledcarbonnanotubesurfactantmodifiedsensorforthedirectdeterminationoftoxicdrug4aminoantipyrine
AT buddanavararunkumart fabricationofmultiwalledcarbonnanotubesurfactantmodifiedsensorforthedirectdeterminationoftoxicdrug4aminoantipyrine
AT nandibewoorsharanappat fabricationofmultiwalledcarbonnanotubesurfactantmodifiedsensorforthedirectdeterminationoftoxicdrug4aminoantipyrine