Cargando…

High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()

A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatizatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Gandhi, Abhishek, Guttikar, Swati, Trivedi, Priti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762240/
https://www.ncbi.nlm.nih.gov/pubmed/29403945
http://dx.doi.org/10.1016/j.jpha.2015.02.002
_version_ 1783291646914330624
author Gandhi, Abhishek
Guttikar, Swati
Trivedi, Priti
author_facet Gandhi, Abhishek
Guttikar, Swati
Trivedi, Priti
author_sort Gandhi, Abhishek
collection PubMed
description A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C(18) (50 mm×4.6 mm, 2.6 µm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100–20.0 ng/mL for levonorgestrel and 4.00–500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies.
format Online
Article
Text
id pubmed-5762240
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57622402018-02-05 High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() Gandhi, Abhishek Guttikar, Swati Trivedi, Priti J Pharm Anal Original Article A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C(18) (50 mm×4.6 mm, 2.6 µm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100–20.0 ng/mL for levonorgestrel and 4.00–500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies. Xi'an Jiaotong University 2015-10 2015-02-20 /pmc/articles/PMC5762240/ /pubmed/29403945 http://dx.doi.org/10.1016/j.jpha.2015.02.002 Text en © 2015 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Gandhi, Abhishek
Guttikar, Swati
Trivedi, Priti
High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
title High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
title_full High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
title_fullStr High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
title_full_unstemmed High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
title_short High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
title_sort high-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762240/
https://www.ncbi.nlm.nih.gov/pubmed/29403945
http://dx.doi.org/10.1016/j.jpha.2015.02.002
work_keys_str_mv AT gandhiabhishek highsensitivitysimultaneousliquidchromatographytandemmassspectrometryassayofethinylestradiolandlevonorgestrelinhumanplasma
AT guttikarswati highsensitivitysimultaneousliquidchromatographytandemmassspectrometryassayofethinylestradiolandlevonorgestrelinhumanplasma
AT trivedipriti highsensitivitysimultaneousliquidchromatographytandemmassspectrometryassayofethinylestradiolandlevonorgestrelinhumanplasma