Cargando…
High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma()
A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatizatio...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762240/ https://www.ncbi.nlm.nih.gov/pubmed/29403945 http://dx.doi.org/10.1016/j.jpha.2015.02.002 |
_version_ | 1783291646914330624 |
---|---|
author | Gandhi, Abhishek Guttikar, Swati Trivedi, Priti |
author_facet | Gandhi, Abhishek Guttikar, Swati Trivedi, Priti |
author_sort | Gandhi, Abhishek |
collection | PubMed |
description | A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C(18) (50 mm×4.6 mm, 2.6 µm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100–20.0 ng/mL for levonorgestrel and 4.00–500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies. |
format | Online Article Text |
id | pubmed-5762240 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-57622402018-02-05 High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() Gandhi, Abhishek Guttikar, Swati Trivedi, Priti J Pharm Anal Original Article A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C(18) (50 mm×4.6 mm, 2.6 µm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100–20.0 ng/mL for levonorgestrel and 4.00–500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies. Xi'an Jiaotong University 2015-10 2015-02-20 /pmc/articles/PMC5762240/ /pubmed/29403945 http://dx.doi.org/10.1016/j.jpha.2015.02.002 Text en © 2015 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Gandhi, Abhishek Guttikar, Swati Trivedi, Priti High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() |
title | High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() |
title_full | High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() |
title_fullStr | High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() |
title_full_unstemmed | High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() |
title_short | High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() |
title_sort | high-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma() |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762240/ https://www.ncbi.nlm.nih.gov/pubmed/29403945 http://dx.doi.org/10.1016/j.jpha.2015.02.002 |
work_keys_str_mv | AT gandhiabhishek highsensitivitysimultaneousliquidchromatographytandemmassspectrometryassayofethinylestradiolandlevonorgestrelinhumanplasma AT guttikarswati highsensitivitysimultaneousliquidchromatographytandemmassspectrometryassayofethinylestradiolandlevonorgestrelinhumanplasma AT trivedipriti highsensitivitysimultaneousliquidchromatographytandemmassspectrometryassayofethinylestradiolandlevonorgestrelinhumanplasma |