Cargando…

Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients()

A new method using high-performance liquid chromatography coupled with ultra violet detection (HPLC–UV) was developed and validated for the simultaneous quantification of atazanavir, dolutegravir, darunavir, efavirenz, etravirine lopinavir, raltegravir, rilpivirine and tipranavir in human plasma. Fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Charbe, Nitin, Baldelli, Sara, Cozzi, Valeria, Castoldi, Simone, Cattaneo, Dario, Clementi, Emilio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762929/
https://www.ncbi.nlm.nih.gov/pubmed/29404009
http://dx.doi.org/10.1016/j.jpha.2016.05.008
_version_ 1783291794222481408
author Charbe, Nitin
Baldelli, Sara
Cozzi, Valeria
Castoldi, Simone
Cattaneo, Dario
Clementi, Emilio
author_facet Charbe, Nitin
Baldelli, Sara
Cozzi, Valeria
Castoldi, Simone
Cattaneo, Dario
Clementi, Emilio
author_sort Charbe, Nitin
collection PubMed
description A new method using high-performance liquid chromatography coupled with ultra violet detection (HPLC–UV) was developed and validated for the simultaneous quantification of atazanavir, dolutegravir, darunavir, efavirenz, etravirine lopinavir, raltegravir, rilpivirine and tipranavir in human plasma. For the first time we reported here the development and validation of an HPLC–UV assay to quantify the frequently administered 9 antiretroviral compounds including dolutegravir and rilpivirine. A simple solid phase extraction procedure was applied to 500 µL aliquots of plasma. The chromatographic separation of the drugs and internal standard (quinoxaline) was achieved with a gradient of acetonitrile and sodium acetate buffer on a C(18) reverse-phase analytical column with a 25 min analytical run time. Calibration curves were optimised according to the therapeutic range of drug concentrations in patients, and the coefficient of determination (r(2)) was higher than 0.99 for all analytes. Mean intraday and interday precisions (RSD) for all compounds were less than 15.0%, and the mean accuracy (% deviation from nominal concentration) was also found to be less than 15.0%. Extraction recovery range was between 80% and 120% for all drugs analysed. The solid phase extraction and HPLC–UV method enable a specific, sensitive, and reliable simultaneous determination of nine antiretroviral agents in plasma. Good extraction efficiency and low limit of HPLC–UV quantification make this method suitable for use in clinical trials and therapeutic drug monitoring.
format Online
Article
Text
id pubmed-5762929
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57629292018-02-05 Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients() Charbe, Nitin Baldelli, Sara Cozzi, Valeria Castoldi, Simone Cattaneo, Dario Clementi, Emilio J Pharm Anal Original Article A new method using high-performance liquid chromatography coupled with ultra violet detection (HPLC–UV) was developed and validated for the simultaneous quantification of atazanavir, dolutegravir, darunavir, efavirenz, etravirine lopinavir, raltegravir, rilpivirine and tipranavir in human plasma. For the first time we reported here the development and validation of an HPLC–UV assay to quantify the frequently administered 9 antiretroviral compounds including dolutegravir and rilpivirine. A simple solid phase extraction procedure was applied to 500 µL aliquots of plasma. The chromatographic separation of the drugs and internal standard (quinoxaline) was achieved with a gradient of acetonitrile and sodium acetate buffer on a C(18) reverse-phase analytical column with a 25 min analytical run time. Calibration curves were optimised according to the therapeutic range of drug concentrations in patients, and the coefficient of determination (r(2)) was higher than 0.99 for all analytes. Mean intraday and interday precisions (RSD) for all compounds were less than 15.0%, and the mean accuracy (% deviation from nominal concentration) was also found to be less than 15.0%. Extraction recovery range was between 80% and 120% for all drugs analysed. The solid phase extraction and HPLC–UV method enable a specific, sensitive, and reliable simultaneous determination of nine antiretroviral agents in plasma. Good extraction efficiency and low limit of HPLC–UV quantification make this method suitable for use in clinical trials and therapeutic drug monitoring. Xi'an Jiaotong University 2016-12 2016-06-14 /pmc/articles/PMC5762929/ /pubmed/29404009 http://dx.doi.org/10.1016/j.jpha.2016.05.008 Text en © 2016 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Charbe, Nitin
Baldelli, Sara
Cozzi, Valeria
Castoldi, Simone
Cattaneo, Dario
Clementi, Emilio
Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients()
title Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients()
title_full Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients()
title_fullStr Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients()
title_full_unstemmed Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients()
title_short Development of an HPLC–UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients()
title_sort development of an hplc–uv assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of hiv-infected patients()
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762929/
https://www.ncbi.nlm.nih.gov/pubmed/29404009
http://dx.doi.org/10.1016/j.jpha.2016.05.008
work_keys_str_mv AT charbenitin developmentofanhplcuvassaymethodforthesimultaneousquantificationofnineantiretroviralagentsintheplasmaofhivinfectedpatients
AT baldellisara developmentofanhplcuvassaymethodforthesimultaneousquantificationofnineantiretroviralagentsintheplasmaofhivinfectedpatients
AT cozzivaleria developmentofanhplcuvassaymethodforthesimultaneousquantificationofnineantiretroviralagentsintheplasmaofhivinfectedpatients
AT castoldisimone developmentofanhplcuvassaymethodforthesimultaneousquantificationofnineantiretroviralagentsintheplasmaofhivinfectedpatients
AT cattaneodario developmentofanhplcuvassaymethodforthesimultaneousquantificationofnineantiretroviralagentsintheplasmaofhivinfectedpatients
AT clementiemilio developmentofanhplcuvassaymethodforthesimultaneousquantificationofnineantiretroviralagentsintheplasmaofhivinfectedpatients