Cargando…

Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation

PURPOSE: This study aims to increase the precision of single‐compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool ba...

Descripción completa

Detalles Bibliográficos
Autores principales: Teixeira, Rui Pedro A.G., Malik, Shaihan J., Hajnal, Joseph V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5763350/
https://www.ncbi.nlm.nih.gov/pubmed/28303617
http://dx.doi.org/10.1002/mrm.26670
_version_ 1783291868345270272
author Teixeira, Rui Pedro A.G.
Malik, Shaihan J.
Hajnal, Joseph V.
author_facet Teixeira, Rui Pedro A.G.
Malik, Shaihan J.
Hajnal, Joseph V.
author_sort Teixeira, Rui Pedro A.G.
collection PubMed
description PURPOSE: This study aims to increase the precision of single‐compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool based on the Crámer‐Rao lower bound (CRLB). METHODS: Following the development of the analysis and design capabilities, phantom and four in vivo subject experiments were performed to compare directly the precision achieved with DESPOT and JSR estimation using published protocols and protocols designed using a proposed CRLB framework. RESULTS: Experimental data demonstrate JSR's ability to decrease relaxometry estimation variance. Phantom results show 72 to 77% improvement using the same data as conventional DESPOT. This is further improved to 81 to 87% using optimal parameters. Both experiments show systematic bias depending on the acquisition parameters used, which are shown to be highly reproducible and to vary with different magnetization transfer conditions. CONCLUSIONS: Compared with DESPOT, JSR produces reproducible relaxation maps with improved precision. Further improvement was achieved using CRLB as a protocol design tool. With this combined approach, it is possible to achieve submillimeter maps of [Formula: see text] in an 11‐min examination, making the approach appealing for potential clinical use. Magn Reson Med 79:234–245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
format Online
Article
Text
id pubmed-5763350
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57633502018-01-17 Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation Teixeira, Rui Pedro A.G. Malik, Shaihan J. Hajnal, Joseph V. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: This study aims to increase the precision of single‐compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool based on the Crámer‐Rao lower bound (CRLB). METHODS: Following the development of the analysis and design capabilities, phantom and four in vivo subject experiments were performed to compare directly the precision achieved with DESPOT and JSR estimation using published protocols and protocols designed using a proposed CRLB framework. RESULTS: Experimental data demonstrate JSR's ability to decrease relaxometry estimation variance. Phantom results show 72 to 77% improvement using the same data as conventional DESPOT. This is further improved to 81 to 87% using optimal parameters. Both experiments show systematic bias depending on the acquisition parameters used, which are shown to be highly reproducible and to vary with different magnetization transfer conditions. CONCLUSIONS: Compared with DESPOT, JSR produces reproducible relaxation maps with improved precision. Further improvement was achieved using CRLB as a protocol design tool. With this combined approach, it is possible to achieve submillimeter maps of [Formula: see text] in an 11‐min examination, making the approach appealing for potential clinical use. Magn Reson Med 79:234–245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2017-03-16 2018-01 /pmc/articles/PMC5763350/ /pubmed/28303617 http://dx.doi.org/10.1002/mrm.26670 Text en © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Imaging Methodology
Teixeira, Rui Pedro A.G.
Malik, Shaihan J.
Hajnal, Joseph V.
Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation
title Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation
title_full Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation
title_fullStr Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation
title_full_unstemmed Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation
title_short Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation
title_sort joint system relaxometry (jsr) and crámer‐rao lower bound optimization of sequence parameters: a framework for enhanced precision of despot t(1) and t(2) estimation
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5763350/
https://www.ncbi.nlm.nih.gov/pubmed/28303617
http://dx.doi.org/10.1002/mrm.26670
work_keys_str_mv AT teixeiraruipedroag jointsystemrelaxometryjsrandcramerraolowerboundoptimizationofsequenceparametersaframeworkforenhancedprecisionofdespott1andt2estimation
AT malikshaihanj jointsystemrelaxometryjsrandcramerraolowerboundoptimizationofsequenceparametersaframeworkforenhancedprecisionofdespott1andt2estimation
AT hajnaljosephv jointsystemrelaxometryjsrandcramerraolowerboundoptimizationofsequenceparametersaframeworkforenhancedprecisionofdespott1andt2estimation