Cargando…
Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation
PURPOSE: This study aims to increase the precision of single‐compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool ba...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5763350/ https://www.ncbi.nlm.nih.gov/pubmed/28303617 http://dx.doi.org/10.1002/mrm.26670 |
_version_ | 1783291868345270272 |
---|---|
author | Teixeira, Rui Pedro A.G. Malik, Shaihan J. Hajnal, Joseph V. |
author_facet | Teixeira, Rui Pedro A.G. Malik, Shaihan J. Hajnal, Joseph V. |
author_sort | Teixeira, Rui Pedro A.G. |
collection | PubMed |
description | PURPOSE: This study aims to increase the precision of single‐compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool based on the Crámer‐Rao lower bound (CRLB). METHODS: Following the development of the analysis and design capabilities, phantom and four in vivo subject experiments were performed to compare directly the precision achieved with DESPOT and JSR estimation using published protocols and protocols designed using a proposed CRLB framework. RESULTS: Experimental data demonstrate JSR's ability to decrease relaxometry estimation variance. Phantom results show 72 to 77% improvement using the same data as conventional DESPOT. This is further improved to 81 to 87% using optimal parameters. Both experiments show systematic bias depending on the acquisition parameters used, which are shown to be highly reproducible and to vary with different magnetization transfer conditions. CONCLUSIONS: Compared with DESPOT, JSR produces reproducible relaxation maps with improved precision. Further improvement was achieved using CRLB as a protocol design tool. With this combined approach, it is possible to achieve submillimeter maps of [Formula: see text] in an 11‐min examination, making the approach appealing for potential clinical use. Magn Reson Med 79:234–245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
format | Online Article Text |
id | pubmed-5763350 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57633502018-01-17 Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation Teixeira, Rui Pedro A.G. Malik, Shaihan J. Hajnal, Joseph V. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: This study aims to increase the precision of single‐compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool based on the Crámer‐Rao lower bound (CRLB). METHODS: Following the development of the analysis and design capabilities, phantom and four in vivo subject experiments were performed to compare directly the precision achieved with DESPOT and JSR estimation using published protocols and protocols designed using a proposed CRLB framework. RESULTS: Experimental data demonstrate JSR's ability to decrease relaxometry estimation variance. Phantom results show 72 to 77% improvement using the same data as conventional DESPOT. This is further improved to 81 to 87% using optimal parameters. Both experiments show systematic bias depending on the acquisition parameters used, which are shown to be highly reproducible and to vary with different magnetization transfer conditions. CONCLUSIONS: Compared with DESPOT, JSR produces reproducible relaxation maps with improved precision. Further improvement was achieved using CRLB as a protocol design tool. With this combined approach, it is possible to achieve submillimeter maps of [Formula: see text] in an 11‐min examination, making the approach appealing for potential clinical use. Magn Reson Med 79:234–245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2017-03-16 2018-01 /pmc/articles/PMC5763350/ /pubmed/28303617 http://dx.doi.org/10.1002/mrm.26670 Text en © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Full Papers—Imaging Methodology Teixeira, Rui Pedro A.G. Malik, Shaihan J. Hajnal, Joseph V. Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation |
title | Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation |
title_full | Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation |
title_fullStr | Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation |
title_full_unstemmed | Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation |
title_short | Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T(1) and T(2) estimation |
title_sort | joint system relaxometry (jsr) and crámer‐rao lower bound optimization of sequence parameters: a framework for enhanced precision of despot t(1) and t(2) estimation |
topic | Full Papers—Imaging Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5763350/ https://www.ncbi.nlm.nih.gov/pubmed/28303617 http://dx.doi.org/10.1002/mrm.26670 |
work_keys_str_mv | AT teixeiraruipedroag jointsystemrelaxometryjsrandcramerraolowerboundoptimizationofsequenceparametersaframeworkforenhancedprecisionofdespott1andt2estimation AT malikshaihanj jointsystemrelaxometryjsrandcramerraolowerboundoptimizationofsequenceparametersaframeworkforenhancedprecisionofdespott1andt2estimation AT hajnaljosephv jointsystemrelaxometryjsrandcramerraolowerboundoptimizationofsequenceparametersaframeworkforenhancedprecisionofdespott1andt2estimation |