Cargando…
Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study
BACKGROUND: Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5764017/ https://www.ncbi.nlm.nih.gov/pubmed/29321010 http://dx.doi.org/10.1186/s12903-017-0458-2 |
_version_ | 1783291999782174720 |
---|---|
author | Sonmez, Nesrin Gultekin, Pinar Turp, Volkan Akgungor, Gokhan Sen, Deniz Mijiritsky, Eitan |
author_facet | Sonmez, Nesrin Gultekin, Pinar Turp, Volkan Akgungor, Gokhan Sen, Deniz Mijiritsky, Eitan |
author_sort | Sonmez, Nesrin |
collection | PubMed |
description | BACKGROUND: Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis. METHODS: Five test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey’s HSD, and Student’s t tests (α = .05). Fractured specimens were evaluated using SEM. RESULTS: The highest Vickers microhardness value was found for VITA Mark II (p < .001), however flexural strength and fracture toughness results were lowest conversely (p < .05). IPS e.max CAD was found to have the highest flexural strength (p < .001). Fracture toughness of IPS e.max CAD was also higher than other tested block materials (p < .001). Lava Ultimate and VITA Enamic’s mechanical properties were affected negatively from thermocycling (p < .05). Microhardness, flexural strength, and fracture toughness values of Lava Ultimate and VITA Enamic were found to be similar to VITA Mark II and IPS Empress CAD groups. CONCLUSIONS: It should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics. |
format | Online Article Text |
id | pubmed-5764017 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-57640172018-01-17 Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study Sonmez, Nesrin Gultekin, Pinar Turp, Volkan Akgungor, Gokhan Sen, Deniz Mijiritsky, Eitan BMC Oral Health Research Article BACKGROUND: Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis. METHODS: Five test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey’s HSD, and Student’s t tests (α = .05). Fractured specimens were evaluated using SEM. RESULTS: The highest Vickers microhardness value was found for VITA Mark II (p < .001), however flexural strength and fracture toughness results were lowest conversely (p < .05). IPS e.max CAD was found to have the highest flexural strength (p < .001). Fracture toughness of IPS e.max CAD was also higher than other tested block materials (p < .001). Lava Ultimate and VITA Enamic’s mechanical properties were affected negatively from thermocycling (p < .05). Microhardness, flexural strength, and fracture toughness values of Lava Ultimate and VITA Enamic were found to be similar to VITA Mark II and IPS Empress CAD groups. CONCLUSIONS: It should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics. BioMed Central 2018-01-08 /pmc/articles/PMC5764017/ /pubmed/29321010 http://dx.doi.org/10.1186/s12903-017-0458-2 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Sonmez, Nesrin Gultekin, Pinar Turp, Volkan Akgungor, Gokhan Sen, Deniz Mijiritsky, Eitan Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study |
title | Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study |
title_full | Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study |
title_fullStr | Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study |
title_full_unstemmed | Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study |
title_short | Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study |
title_sort | evaluation of five cad/cam materials by microstructural characterization and mechanical tests: a comparative in vitro study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5764017/ https://www.ncbi.nlm.nih.gov/pubmed/29321010 http://dx.doi.org/10.1186/s12903-017-0458-2 |
work_keys_str_mv | AT sonmeznesrin evaluationoffivecadcammaterialsbymicrostructuralcharacterizationandmechanicaltestsacomparativeinvitrostudy AT gultekinpinar evaluationoffivecadcammaterialsbymicrostructuralcharacterizationandmechanicaltestsacomparativeinvitrostudy AT turpvolkan evaluationoffivecadcammaterialsbymicrostructuralcharacterizationandmechanicaltestsacomparativeinvitrostudy AT akgungorgokhan evaluationoffivecadcammaterialsbymicrostructuralcharacterizationandmechanicaltestsacomparativeinvitrostudy AT sendeniz evaluationoffivecadcammaterialsbymicrostructuralcharacterizationandmechanicaltestsacomparativeinvitrostudy AT mijiritskyeitan evaluationoffivecadcammaterialsbymicrostructuralcharacterizationandmechanicaltestsacomparativeinvitrostudy |