Bedside ultrasound is a practical measurement tool for assessing muscle mass

OBJECTIVE: To evaluate the intra- and inter-reliability and the ease of measuring the quadriceps muscle thickness using bedside ultrasound. METHODS: This is a prospective, observational study. The assessment of quadriceps muscle thickness was performed at two reference points and was quantified usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Toledo, Diogo Oliveira, Silva, Débora Carneiro de Lima e, dos Santos, Dyaiane Marques, de Freitas, Branca Jardini, Dib, Rogério, Cordioli, Ricardo Luiz, Figueiredo, Evandro José de Almeida, Piovacari, Silvia Maria Fraga, Silva Jr., João Manoel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação de Medicina Intensiva Brasileira - AMIB 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5764560/
https://www.ncbi.nlm.nih.gov/pubmed/29340537
http://dx.doi.org/10.5935/0103-507X.20170071
_version_ 1783292070873530368
author Toledo, Diogo Oliveira
Silva, Débora Carneiro de Lima e
dos Santos, Dyaiane Marques
de Freitas, Branca Jardini
Dib, Rogério
Cordioli, Ricardo Luiz
Figueiredo, Evandro José de Almeida
Piovacari, Silvia Maria Fraga
Silva Jr., João Manoel
author_facet Toledo, Diogo Oliveira
Silva, Débora Carneiro de Lima e
dos Santos, Dyaiane Marques
de Freitas, Branca Jardini
Dib, Rogério
Cordioli, Ricardo Luiz
Figueiredo, Evandro José de Almeida
Piovacari, Silvia Maria Fraga
Silva Jr., João Manoel
author_sort Toledo, Diogo Oliveira
collection PubMed
description OBJECTIVE: To evaluate the intra- and inter-reliability and the ease of measuring the quadriceps muscle thickness using bedside ultrasound. METHODS: This is a prospective, observational study. The assessment of quadriceps muscle thickness was performed at two reference points and was quantified using portable B-mode ultrasound in two healthy volunteers. For standardization of measurements and validation of image collections, the team was trained through theoretical and practical classes, with a 6-hour workload. RESULTS: A total of 112 images were examined by the coach and compared with the trainees. Pearson's correlation analysis found an excellent relationship between the coach and all trainees (R(2) > 0.90). The best association was between the coach and the dietitians (R(2): 0.99; p < 0.001), and the worst association was between the coach and the medical trainees (R(2): 0.92; p < 0.001). In the Bland-Altman comparison, the highest error rate found between coach and trainees was 5.12% (95% confidence interval [CI] 3.64-12.37), and the lowest was 1.01% (95%CI 0.72 - 2.58); the highest bias of the values described was -0.12 ± 0.19, and the lowest was -0.01 ± 0.04. CONCLUSION: The data analyzed showed a good correlation between the measurements made by the coach and trainees, indicating that ultrasound of the quadriceps muscle is a viable and easily applicable tool.
format Online
Article
Text
id pubmed-5764560
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Associação de Medicina Intensiva Brasileira - AMIB
record_format MEDLINE/PubMed
spelling pubmed-57645602018-01-17 Bedside ultrasound is a practical measurement tool for assessing muscle mass Toledo, Diogo Oliveira Silva, Débora Carneiro de Lima e dos Santos, Dyaiane Marques de Freitas, Branca Jardini Dib, Rogério Cordioli, Ricardo Luiz Figueiredo, Evandro José de Almeida Piovacari, Silvia Maria Fraga Silva Jr., João Manoel Rev Bras Ter Intensiva Original Articles OBJECTIVE: To evaluate the intra- and inter-reliability and the ease of measuring the quadriceps muscle thickness using bedside ultrasound. METHODS: This is a prospective, observational study. The assessment of quadriceps muscle thickness was performed at two reference points and was quantified using portable B-mode ultrasound in two healthy volunteers. For standardization of measurements and validation of image collections, the team was trained through theoretical and practical classes, with a 6-hour workload. RESULTS: A total of 112 images were examined by the coach and compared with the trainees. Pearson's correlation analysis found an excellent relationship between the coach and all trainees (R(2) > 0.90). The best association was between the coach and the dietitians (R(2): 0.99; p < 0.001), and the worst association was between the coach and the medical trainees (R(2): 0.92; p < 0.001). In the Bland-Altman comparison, the highest error rate found between coach and trainees was 5.12% (95% confidence interval [CI] 3.64-12.37), and the lowest was 1.01% (95%CI 0.72 - 2.58); the highest bias of the values described was -0.12 ± 0.19, and the lowest was -0.01 ± 0.04. CONCLUSION: The data analyzed showed a good correlation between the measurements made by the coach and trainees, indicating that ultrasound of the quadriceps muscle is a viable and easily applicable tool. Associação de Medicina Intensiva Brasileira - AMIB 2017 /pmc/articles/PMC5764560/ /pubmed/29340537 http://dx.doi.org/10.5935/0103-507X.20170071 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Toledo, Diogo Oliveira
Silva, Débora Carneiro de Lima e
dos Santos, Dyaiane Marques
de Freitas, Branca Jardini
Dib, Rogério
Cordioli, Ricardo Luiz
Figueiredo, Evandro José de Almeida
Piovacari, Silvia Maria Fraga
Silva Jr., João Manoel
Bedside ultrasound is a practical measurement tool for assessing muscle mass
title Bedside ultrasound is a practical measurement tool for assessing muscle mass
title_full Bedside ultrasound is a practical measurement tool for assessing muscle mass
title_fullStr Bedside ultrasound is a practical measurement tool for assessing muscle mass
title_full_unstemmed Bedside ultrasound is a practical measurement tool for assessing muscle mass
title_short Bedside ultrasound is a practical measurement tool for assessing muscle mass
title_sort bedside ultrasound is a practical measurement tool for assessing muscle mass
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5764560/
https://www.ncbi.nlm.nih.gov/pubmed/29340537
http://dx.doi.org/10.5935/0103-507X.20170071
work_keys_str_mv AT toledodiogooliveira bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT silvadeboracarneirodelimae bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT dossantosdyaianemarques bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT defreitasbrancajardini bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT dibrogerio bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT cordioliricardoluiz bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT figueiredoevandrojosedealmeida bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT piovacarisilviamariafraga bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass
AT silvajrjoaomanoel bedsideultrasoundisapracticalmeasurementtoolforassessingmusclemass