Cargando…
Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report
Radiosurgery serves an important function in the treatment of patients with intraocular tumors and preserves visual function via organ conservation. Therefore, it is important to ensure the safety and precision of GK-SRS as a primary treatment for intraocular tumors. The present case study described...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5766057/ https://www.ncbi.nlm.nih.gov/pubmed/29375706 http://dx.doi.org/10.3892/ol.2017.7300 |
_version_ | 1783292307418644480 |
---|---|
author | Tsai, Yi-Chieh Kuo, Chun-Yuan Lin, Jia-Wei Yang, Shun-Tai Lai, Shih-Chung Tsai, Jo-Ting |
author_facet | Tsai, Yi-Chieh Kuo, Chun-Yuan Lin, Jia-Wei Yang, Shun-Tai Lai, Shih-Chung Tsai, Jo-Ting |
author_sort | Tsai, Yi-Chieh |
collection | PubMed |
description | Radiosurgery serves an important function in the treatment of patients with intraocular tumors and preserves visual function via organ conservation. Therefore, it is important to ensure the safety and precision of GK-SRS as a primary treatment for intraocular tumors. The present case study described a 57-year-old female with uveal melanoma treated with GK-SRS. Retrobulbar anesthesia following fixation of the treated eye, via the suture of two of the extraocular muscles to the stereotactic frame, was performed to immobilize the eye during treatment. Computed tomography (CT) scans were performed following eye fixation, immediately prior to and following GK-SRS, to validate the accuracy of the tumor localization. The eye movement analysis revealed that the gravity center point deviations of the tumor and lens during treatment were <0.110 mm. At least 95% of the tumor volume was covered by the prescription dose according to three sets of CT images. The patient underwent a trans pars plana vitrectomy owing to a right eye vitreous hemorrhage. A 37-month follow-up assessment revealed tumor shrinkage, and the disappearance of the serous retinal detachments was noted on the basis of ophthalmoscopy and orbital magnetic resonance imaging. No major complications developed during the follow-up period. Using our treatment protocol, GK-SRS is a non-invasive procedure which is used as a brief single fraction treatment for intraocular tumor. The eye fixation method used in the present study has high accuracy. |
format | Online Article Text |
id | pubmed-5766057 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-57660572018-01-28 Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report Tsai, Yi-Chieh Kuo, Chun-Yuan Lin, Jia-Wei Yang, Shun-Tai Lai, Shih-Chung Tsai, Jo-Ting Oncol Lett Articles Radiosurgery serves an important function in the treatment of patients with intraocular tumors and preserves visual function via organ conservation. Therefore, it is important to ensure the safety and precision of GK-SRS as a primary treatment for intraocular tumors. The present case study described a 57-year-old female with uveal melanoma treated with GK-SRS. Retrobulbar anesthesia following fixation of the treated eye, via the suture of two of the extraocular muscles to the stereotactic frame, was performed to immobilize the eye during treatment. Computed tomography (CT) scans were performed following eye fixation, immediately prior to and following GK-SRS, to validate the accuracy of the tumor localization. The eye movement analysis revealed that the gravity center point deviations of the tumor and lens during treatment were <0.110 mm. At least 95% of the tumor volume was covered by the prescription dose according to three sets of CT images. The patient underwent a trans pars plana vitrectomy owing to a right eye vitreous hemorrhage. A 37-month follow-up assessment revealed tumor shrinkage, and the disappearance of the serous retinal detachments was noted on the basis of ophthalmoscopy and orbital magnetic resonance imaging. No major complications developed during the follow-up period. Using our treatment protocol, GK-SRS is a non-invasive procedure which is used as a brief single fraction treatment for intraocular tumor. The eye fixation method used in the present study has high accuracy. D.A. Spandidos 2018-01 2017-10-31 /pmc/articles/PMC5766057/ /pubmed/29375706 http://dx.doi.org/10.3892/ol.2017.7300 Text en Copyright: © Tsai et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Tsai, Yi-Chieh Kuo, Chun-Yuan Lin, Jia-Wei Yang, Shun-Tai Lai, Shih-Chung Tsai, Jo-Ting Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report |
title | Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report |
title_full | Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report |
title_fullStr | Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report |
title_full_unstemmed | Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report |
title_short | Gamma Knife Perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report |
title_sort | gamma knife perfexion(®) radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: a case report |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5766057/ https://www.ncbi.nlm.nih.gov/pubmed/29375706 http://dx.doi.org/10.3892/ol.2017.7300 |
work_keys_str_mv | AT tsaiyichieh gammaknifeperfexionradiosurgeryandendodiodelaserthermotherapyforchoroidalmelanomawithtechnicalanalysisacasereport AT kuochunyuan gammaknifeperfexionradiosurgeryandendodiodelaserthermotherapyforchoroidalmelanomawithtechnicalanalysisacasereport AT linjiawei gammaknifeperfexionradiosurgeryandendodiodelaserthermotherapyforchoroidalmelanomawithtechnicalanalysisacasereport AT yangshuntai gammaknifeperfexionradiosurgeryandendodiodelaserthermotherapyforchoroidalmelanomawithtechnicalanalysisacasereport AT laishihchung gammaknifeperfexionradiosurgeryandendodiodelaserthermotherapyforchoroidalmelanomawithtechnicalanalysisacasereport AT tsaijoting gammaknifeperfexionradiosurgeryandendodiodelaserthermotherapyforchoroidalmelanomawithtechnicalanalysisacasereport |