Cargando…

Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study

INTRODUCTION: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. MATERIALS AND METHODS: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavit...

Descripción completa

Detalles Bibliográficos
Autores principales: Saha, Suparna Ganguly, Vijaywargiya, Neelam, Saxena, Divya, Saha, Mainak Kanti, Bharadwaj, Anuj, Dubey, Sandeep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5767833/
https://www.ncbi.nlm.nih.gov/pubmed/29386786
http://dx.doi.org/10.4103/JCD.JCD_70_17
_version_ 1783292604384804864
author Saha, Suparna Ganguly
Vijaywargiya, Neelam
Saxena, Divya
Saha, Mainak Kanti
Bharadwaj, Anuj
Dubey, Sandeep
author_facet Saha, Suparna Ganguly
Vijaywargiya, Neelam
Saxena, Divya
Saha, Mainak Kanti
Bharadwaj, Anuj
Dubey, Sandeep
author_sort Saha, Suparna Ganguly
collection PubMed
description INTRODUCTION: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. MATERIALS AND METHODS: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. RESULTS: The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). CONCLUSION: All nickel–titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.
format Online
Article
Text
id pubmed-5767833
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-57678332018-01-31 Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study Saha, Suparna Ganguly Vijaywargiya, Neelam Saxena, Divya Saha, Mainak Kanti Bharadwaj, Anuj Dubey, Sandeep J Conserv Dent Original Research Article INTRODUCTION: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. MATERIALS AND METHODS: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. RESULTS: The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). CONCLUSION: All nickel–titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5767833/ /pubmed/29386786 http://dx.doi.org/10.4103/JCD.JCD_70_17 Text en Copyright: © 2017 Journal of Conservative Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Research Article
Saha, Suparna Ganguly
Vijaywargiya, Neelam
Saxena, Divya
Saha, Mainak Kanti
Bharadwaj, Anuj
Dubey, Sandeep
Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study
title Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study
title_full Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study
title_fullStr Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study
title_full_unstemmed Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study
title_short Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study
title_sort evaluation of the incidence of microcracks caused by mtwo and protaper next rotary file systems versus the self-adjusting file: a scanning electron microscopic study
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5767833/
https://www.ncbi.nlm.nih.gov/pubmed/29386786
http://dx.doi.org/10.4103/JCD.JCD_70_17
work_keys_str_mv AT sahasuparnaganguly evaluationoftheincidenceofmicrocrackscausedbymtwoandprotapernextrotaryfilesystemsversustheselfadjustingfileascanningelectronmicroscopicstudy
AT vijaywargiyaneelam evaluationoftheincidenceofmicrocrackscausedbymtwoandprotapernextrotaryfilesystemsversustheselfadjustingfileascanningelectronmicroscopicstudy
AT saxenadivya evaluationoftheincidenceofmicrocrackscausedbymtwoandprotapernextrotaryfilesystemsversustheselfadjustingfileascanningelectronmicroscopicstudy
AT sahamainakkanti evaluationoftheincidenceofmicrocrackscausedbymtwoandprotapernextrotaryfilesystemsversustheselfadjustingfileascanningelectronmicroscopicstudy
AT bharadwajanuj evaluationoftheincidenceofmicrocrackscausedbymtwoandprotapernextrotaryfilesystemsversustheselfadjustingfileascanningelectronmicroscopicstudy
AT dubeysandeep evaluationoftheincidenceofmicrocrackscausedbymtwoandprotapernextrotaryfilesystemsversustheselfadjustingfileascanningelectronmicroscopicstudy