Cargando…
On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system
Inverse planning optimization using biologically based objectives is becoming part of the intensity modulated optimization process. The performances and efficacy of the biologically based gEUD (generalized Equivalent Uniform Dose) objective implemented in the Photon Optimizer (PO) of Varian Eclipse...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5768006/ https://www.ncbi.nlm.nih.gov/pubmed/29152846 http://dx.doi.org/10.1002/acm2.12224 |
_version_ | 1783292632496078848 |
---|---|
author | Fogliata, Antonella Thompson, Stephen Stravato, Antonella Tomatis, Stefano Scorsetti, Marta Cozzi, Luca |
author_facet | Fogliata, Antonella Thompson, Stephen Stravato, Antonella Tomatis, Stefano Scorsetti, Marta Cozzi, Luca |
author_sort | Fogliata, Antonella |
collection | PubMed |
description | Inverse planning optimization using biologically based objectives is becoming part of the intensity modulated optimization process. The performances and efficacy of the biologically based gEUD (generalized Equivalent Uniform Dose) objective implemented in the Photon Optimizer (PO) of Varian Eclipse treatment planning system have been here analyzed. gEUD is associated with the parameter a that accounts for the seriality of a structure, being higher for more serial organs. The PO was used to optimize volumetric modulated arc therapy (VMAT) plans on a virtual homogeneous cylindrical phantom presenting a target and an organ at risk (OAR). The OAR was placed at 4 mm, 1 and 2 cm distance, or cropped at 0, 2 and 4 mm from the target. Homogeneous target dose of 60 Gy in 20 fractions was requested with physical dose‐volume objectives, while OAR dose was minimized with the upper gEUD objective. The gEUD specific a parameter was varied from 0.1 to 40 to assess its impact to OAR sparing and target coverage. Actual head and neck and prostate cases, with one parotid and the rectum as test OAR, were also analyzed to translate the results in the more complex clinical environment. Increasing the a parameter value in the gEUD objective, the optimization achieved lower volumes of the OAR which received the highest dose levels. The maximum dose in the OAR was minimized well with a values up to 20, while further increase of a to 40 did not further improve the result. The OAR mean dose was reduced for the OAR located at 1 and 2 cm distance from the target, enforced with increasing a. For cropped OARs, a mean dose reduction was achieved for a values up to 3–5, but mean dose increased for higher a values. The optimal choice of the parameter a depends on the mutual OAR and target position, and seriality of the organ. Today no significant compendium of clinical and biological specific a and gEUD values are available for a wide range of OARs. |
format | Online Article Text |
id | pubmed-5768006 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57680062018-04-02 On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system Fogliata, Antonella Thompson, Stephen Stravato, Antonella Tomatis, Stefano Scorsetti, Marta Cozzi, Luca J Appl Clin Med Phys Radiation Oncology Physics Inverse planning optimization using biologically based objectives is becoming part of the intensity modulated optimization process. The performances and efficacy of the biologically based gEUD (generalized Equivalent Uniform Dose) objective implemented in the Photon Optimizer (PO) of Varian Eclipse treatment planning system have been here analyzed. gEUD is associated with the parameter a that accounts for the seriality of a structure, being higher for more serial organs. The PO was used to optimize volumetric modulated arc therapy (VMAT) plans on a virtual homogeneous cylindrical phantom presenting a target and an organ at risk (OAR). The OAR was placed at 4 mm, 1 and 2 cm distance, or cropped at 0, 2 and 4 mm from the target. Homogeneous target dose of 60 Gy in 20 fractions was requested with physical dose‐volume objectives, while OAR dose was minimized with the upper gEUD objective. The gEUD specific a parameter was varied from 0.1 to 40 to assess its impact to OAR sparing and target coverage. Actual head and neck and prostate cases, with one parotid and the rectum as test OAR, were also analyzed to translate the results in the more complex clinical environment. Increasing the a parameter value in the gEUD objective, the optimization achieved lower volumes of the OAR which received the highest dose levels. The maximum dose in the OAR was minimized well with a values up to 20, while further increase of a to 40 did not further improve the result. The OAR mean dose was reduced for the OAR located at 1 and 2 cm distance from the target, enforced with increasing a. For cropped OARs, a mean dose reduction was achieved for a values up to 3–5, but mean dose increased for higher a values. The optimal choice of the parameter a depends on the mutual OAR and target position, and seriality of the organ. Today no significant compendium of clinical and biological specific a and gEUD values are available for a wide range of OARs. John Wiley and Sons Inc. 2017-11-20 /pmc/articles/PMC5768006/ /pubmed/29152846 http://dx.doi.org/10.1002/acm2.12224 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Fogliata, Antonella Thompson, Stephen Stravato, Antonella Tomatis, Stefano Scorsetti, Marta Cozzi, Luca On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system |
title | On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system |
title_full | On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system |
title_fullStr | On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system |
title_full_unstemmed | On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system |
title_short | On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system |
title_sort | on the geud biological optimization objective for organs at risk in photon optimizer of eclipse treatment planning system |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5768006/ https://www.ncbi.nlm.nih.gov/pubmed/29152846 http://dx.doi.org/10.1002/acm2.12224 |
work_keys_str_mv | AT fogliataantonella onthegeudbiologicaloptimizationobjectivefororgansatriskinphotonoptimizerofeclipsetreatmentplanningsystem AT thompsonstephen onthegeudbiologicaloptimizationobjectivefororgansatriskinphotonoptimizerofeclipsetreatmentplanningsystem AT stravatoantonella onthegeudbiologicaloptimizationobjectivefororgansatriskinphotonoptimizerofeclipsetreatmentplanningsystem AT tomatisstefano onthegeudbiologicaloptimizationobjectivefororgansatriskinphotonoptimizerofeclipsetreatmentplanningsystem AT scorsettimarta onthegeudbiologicaloptimizationobjectivefororgansatriskinphotonoptimizerofeclipsetreatmentplanningsystem AT cozziluca onthegeudbiologicaloptimizationobjectivefororgansatriskinphotonoptimizerofeclipsetreatmentplanningsystem |