Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization

Normalize the response of electronic portal imaging device (EPID) is the first step toward an EPID‐based standardization of Linear Accelerator (linac) dosimetry quality assurance. In this study, we described an approach to generate two‐dimensional (2D) pixel sensitivity maps (PSM) for EPIDs response...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Bin, Goddu, S. Murty, Yaddanapudi, Sridhar, Caruthers, Douglas, Wen, Jie, Noel, Camille, Mutic, Sasa, Sun, Baozhou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5768011/
https://www.ncbi.nlm.nih.gov/pubmed/29125224
http://dx.doi.org/10.1002/acm2.12222
_version_ 1783292633707184128
author Cai, Bin
Goddu, S. Murty
Yaddanapudi, Sridhar
Caruthers, Douglas
Wen, Jie
Noel, Camille
Mutic, Sasa
Sun, Baozhou
author_facet Cai, Bin
Goddu, S. Murty
Yaddanapudi, Sridhar
Caruthers, Douglas
Wen, Jie
Noel, Camille
Mutic, Sasa
Sun, Baozhou
author_sort Cai, Bin
collection PubMed
description Normalize the response of electronic portal imaging device (EPID) is the first step toward an EPID‐based standardization of Linear Accelerator (linac) dosimetry quality assurance. In this study, we described an approach to generate two‐dimensional (2D) pixel sensitivity maps (PSM) for EPIDs response normalization utilizing an alternative beam and dark‐field (ABDF) image acquisition technique and large overlapping field irradiations. The automated image acquisition was performed by XML‐controlled machine operation and the PSM was generated based on a recursive calculation algorithm for Varian linacs equipped with aS1000 and aS1200 imager panels. Cross‐comparisons of normalized beam profiles and 1.5%/1.5 mm 1D Gamma analysis was adopted to quantify the improvement of beam profile matching before and after PSM corrections. PSMs were derived for both photon (6, 10, 15 MV) and electron (6, 20 MeV) beams via proposed method. The PSM‐corrected images reproduced a horn‐shaped profile for photon beams and a relative uniform profiles for electrons. For dosimetrically matched linacs equipped with aS1000 panels, PSM‐corrected images showed increased 1D‐Gamma passing rates for all energies, with an average 10.5% improvement for crossline and 37% for inline beam profiles. Similar improvements in the phantom study were observed with a maximum improvement of 32% for 15 MV and 22% for 20 MeV. The PSM value showed no significant change for all energies over a 3‐month period. In conclusion, the proposed approach correct EPID response for both aS1000 and aS1200 panels. This strategy enables the possibility to standardize linac dosimetry QA and to benchmark linac performance utilizing EPID as the common detector.
format Online
Article
Text
id pubmed-5768011
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57680112018-04-02 Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization Cai, Bin Goddu, S. Murty Yaddanapudi, Sridhar Caruthers, Douglas Wen, Jie Noel, Camille Mutic, Sasa Sun, Baozhou J Appl Clin Med Phys Radiation Oncology Physics Normalize the response of electronic portal imaging device (EPID) is the first step toward an EPID‐based standardization of Linear Accelerator (linac) dosimetry quality assurance. In this study, we described an approach to generate two‐dimensional (2D) pixel sensitivity maps (PSM) for EPIDs response normalization utilizing an alternative beam and dark‐field (ABDF) image acquisition technique and large overlapping field irradiations. The automated image acquisition was performed by XML‐controlled machine operation and the PSM was generated based on a recursive calculation algorithm for Varian linacs equipped with aS1000 and aS1200 imager panels. Cross‐comparisons of normalized beam profiles and 1.5%/1.5 mm 1D Gamma analysis was adopted to quantify the improvement of beam profile matching before and after PSM corrections. PSMs were derived for both photon (6, 10, 15 MV) and electron (6, 20 MeV) beams via proposed method. The PSM‐corrected images reproduced a horn‐shaped profile for photon beams and a relative uniform profiles for electrons. For dosimetrically matched linacs equipped with aS1000 panels, PSM‐corrected images showed increased 1D‐Gamma passing rates for all energies, with an average 10.5% improvement for crossline and 37% for inline beam profiles. Similar improvements in the phantom study were observed with a maximum improvement of 32% for 15 MV and 22% for 20 MeV. The PSM value showed no significant change for all energies over a 3‐month period. In conclusion, the proposed approach correct EPID response for both aS1000 and aS1200 panels. This strategy enables the possibility to standardize linac dosimetry QA and to benchmark linac performance utilizing EPID as the common detector. John Wiley and Sons Inc. 2017-11-10 /pmc/articles/PMC5768011/ /pubmed/29125224 http://dx.doi.org/10.1002/acm2.12222 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Cai, Bin
Goddu, S. Murty
Yaddanapudi, Sridhar
Caruthers, Douglas
Wen, Jie
Noel, Camille
Mutic, Sasa
Sun, Baozhou
Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization
title Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization
title_full Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization
title_fullStr Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization
title_full_unstemmed Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization
title_short Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization
title_sort normalize the response of epid in pursuit of linear accelerator dosimetry standardization
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5768011/
https://www.ncbi.nlm.nih.gov/pubmed/29125224
http://dx.doi.org/10.1002/acm2.12222
work_keys_str_mv AT caibin normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization
AT goddusmurty normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization
AT yaddanapudisridhar normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization
AT caruthersdouglas normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization
AT wenjie normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization
AT noelcamille normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization
AT muticsasa normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization
AT sunbaozhou normalizetheresponseofepidinpursuitoflinearacceleratordosimetrystandardization