Cargando…

Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography

OBJECTIVE: To exploit material decomposition analysis in dual-energy spectral computed tomography (CT) to assess the blood supply status of the ground-glass opacity (GGO) in lungs. MATERIALS AND METHODS: This retrospective study included 48 patients with lung adenocarcinoma, who underwent a contrast...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Guanfu, Li, Mengying, Li, Guosheng, Li, Zhiyong, Liu, Ailian, Pu, Renwang, Cao, Huizhi, Liu, Yijun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5768493/
https://www.ncbi.nlm.nih.gov/pubmed/29354009
http://dx.doi.org/10.3348/kjr.2018.19.1.130
_version_ 1783292712624062464
author Liu, Guanfu
Li, Mengying
Li, Guosheng
Li, Zhiyong
Liu, Ailian
Pu, Renwang
Cao, Huizhi
Liu, Yijun
author_facet Liu, Guanfu
Li, Mengying
Li, Guosheng
Li, Zhiyong
Liu, Ailian
Pu, Renwang
Cao, Huizhi
Liu, Yijun
author_sort Liu, Guanfu
collection PubMed
description OBJECTIVE: To exploit material decomposition analysis in dual-energy spectral computed tomography (CT) to assess the blood supply status of the ground-glass opacity (GGO) in lungs. MATERIALS AND METHODS: This retrospective study included 48 patients with lung adenocarcinoma, who underwent a contrast-enhanced dual-energy spectral CT scan before treatment (53 GGOs in total). The iodine concentration (IC) and water content (WC) of the GGO, the contralateral and ipsilateral normal lung tissues were measured in the arterial phase (AP) and their differences were analyzed. IC, normalized IC (NIC), and WC values were compared between the pure ground-glass opacity (pGGO) and the mixed ground-glass opacity (mGGO), and between the group of preinvasive lesions and the minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IA) groups. RESULTS: The values of pGGO (IC = 20.9 ± 6.2 mg/mL and WC = 345.1 ± 87.1 mg/mL) and mGGO (IC = 23.8 ± 8.3 mg/mL and WC = 606.8 ± 124.5 mg/mL) in the AP were significantly higher than those of the contralateral normal lung tissues (IC = 15.0 ± 4.9 mg/mL and WC = 156.4 ± 36.8 mg/mL; IC = 16.2 ± 5.7 mg/mL and WC = 169.4 ± 41.0 mg/mL) and ipsilateral normal lung tissues (IC = 15.1 ± 6.2 mg/mL and WC = 156.3 ± 38.8 mg/mL; IC = 15.9 ± 6.0 mg/mL and WC = 174.7 ± 39.2 mg/mL; all p < 0.001). After normalizing the data according to the values of the artery, pGGO (NIC = 0.1 and WC = 345.1 ± 87.1 mg/mL) and mGGO (NIC = 0.2 and WC = 606.8 ± 124.5 mg/mL) were statistically different (p = 0.049 and p < 0.001, respectively), but not for the IC value (p = 0.161). The WC values of the group with preinvasive lesions and MIA (345.4 ± 96.1 mg/mL) and IA (550.1 ± 158.2 mg/mL) were statistically different (p < 0.001). CONCLUSION: Using dual-energy spectral CT and material decomposition analysis, the IC in GGO can be quantitatively measured which can be an indicator of the blood supply status in the GGO.
format Online
Article
Text
id pubmed-5768493
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-57684932018-01-21 Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography Liu, Guanfu Li, Mengying Li, Guosheng Li, Zhiyong Liu, Ailian Pu, Renwang Cao, Huizhi Liu, Yijun Korean J Radiol Thoracic Imaging OBJECTIVE: To exploit material decomposition analysis in dual-energy spectral computed tomography (CT) to assess the blood supply status of the ground-glass opacity (GGO) in lungs. MATERIALS AND METHODS: This retrospective study included 48 patients with lung adenocarcinoma, who underwent a contrast-enhanced dual-energy spectral CT scan before treatment (53 GGOs in total). The iodine concentration (IC) and water content (WC) of the GGO, the contralateral and ipsilateral normal lung tissues were measured in the arterial phase (AP) and their differences were analyzed. IC, normalized IC (NIC), and WC values were compared between the pure ground-glass opacity (pGGO) and the mixed ground-glass opacity (mGGO), and between the group of preinvasive lesions and the minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IA) groups. RESULTS: The values of pGGO (IC = 20.9 ± 6.2 mg/mL and WC = 345.1 ± 87.1 mg/mL) and mGGO (IC = 23.8 ± 8.3 mg/mL and WC = 606.8 ± 124.5 mg/mL) in the AP were significantly higher than those of the contralateral normal lung tissues (IC = 15.0 ± 4.9 mg/mL and WC = 156.4 ± 36.8 mg/mL; IC = 16.2 ± 5.7 mg/mL and WC = 169.4 ± 41.0 mg/mL) and ipsilateral normal lung tissues (IC = 15.1 ± 6.2 mg/mL and WC = 156.3 ± 38.8 mg/mL; IC = 15.9 ± 6.0 mg/mL and WC = 174.7 ± 39.2 mg/mL; all p < 0.001). After normalizing the data according to the values of the artery, pGGO (NIC = 0.1 and WC = 345.1 ± 87.1 mg/mL) and mGGO (NIC = 0.2 and WC = 606.8 ± 124.5 mg/mL) were statistically different (p = 0.049 and p < 0.001, respectively), but not for the IC value (p = 0.161). The WC values of the group with preinvasive lesions and MIA (345.4 ± 96.1 mg/mL) and IA (550.1 ± 158.2 mg/mL) were statistically different (p < 0.001). CONCLUSION: Using dual-energy spectral CT and material decomposition analysis, the IC in GGO can be quantitatively measured which can be an indicator of the blood supply status in the GGO. The Korean Society of Radiology 2018 2018-01-02 /pmc/articles/PMC5768493/ /pubmed/29354009 http://dx.doi.org/10.3348/kjr.2018.19.1.130 Text en Copyright © 2018 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Thoracic Imaging
Liu, Guanfu
Li, Mengying
Li, Guosheng
Li, Zhiyong
Liu, Ailian
Pu, Renwang
Cao, Huizhi
Liu, Yijun
Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography
title Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography
title_full Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography
title_fullStr Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography
title_full_unstemmed Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography
title_short Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography
title_sort assessing the blood supply status of the focal ground-glass opacity in lungs using spectral computed tomography
topic Thoracic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5768493/
https://www.ncbi.nlm.nih.gov/pubmed/29354009
http://dx.doi.org/10.3348/kjr.2018.19.1.130
work_keys_str_mv AT liuguanfu assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography
AT limengying assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography
AT liguosheng assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography
AT lizhiyong assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography
AT liuailian assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography
AT purenwang assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography
AT caohuizhi assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography
AT liuyijun assessingthebloodsupplystatusofthefocalgroundglassopacityinlungsusingspectralcomputedtomography