Cargando…

Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP

BACKGROUND AND STUDY AIMS : Endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) is an alternative to percutaneous transhepatic biliary drainage (PTBD) for patients with malignant distal biliary obstruction in whom ERCP has failed. We studied technical success, clinical success, stent paten...

Descripción completa

Detalles Bibliográficos
Autores principales: Rai, Praveer, Lokesh, CR, Goel, Amit, Aggarwal, Rakesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: © Georg Thieme Verlag KG 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5770273/
https://www.ncbi.nlm.nih.gov/pubmed/29344562
http://dx.doi.org/10.1055/s-0043-120664
_version_ 1783293040483368960
author Rai, Praveer
Lokesh, CR
Goel, Amit
Aggarwal, Rakesh
author_facet Rai, Praveer
Lokesh, CR
Goel, Amit
Aggarwal, Rakesh
author_sort Rai, Praveer
collection PubMed
description BACKGROUND AND STUDY AIMS : Endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) is an alternative to percutaneous transhepatic biliary drainage (PTBD) for patients with malignant distal biliary obstruction in whom ERCP has failed. We studied technical success, clinical success, stent patency rate and occurrence of adverse events in patients undergoing EUS-CDS with partially-covered self-expanding metal stent (PCSEMS). PATIENTS AND METHODS : Medical records of consecutive patients with unresectable malignant distal biliary obstruction requiring biliary drainage who underwent EUS-CDS because of failure of attempt at ERCP were reviewed. EUS-CDS was done using 6-cm, PCSEMS (Wallflex, Boston Scientific). Technical success, clinical success (more than 50 % reduction in total bilirubin at 2 weeks post-procedure), stent patency rate and adverse events (AEs) were assessed. Patients were followed up for 3 months post-procedure. RESULTS : Between January 2015 and December 2016, 30 patients underwent EUS-CDS, including 20 (67 %) with failed biliary cannulation and 10 (33 %) with duodenal stenosis. Technical success was achieved in 28 patients, all of whom also had clinical success. Median total serum bilirubin decreased from 20 mg/dL to 5 mg/dL at 2 weeks post-procedure. Three patients (10 %) had adverse events (bile leak, hemobilia, stent block in one patient each; no stent migration); none of these adverse events was major and all were managed successfully. There were no procedure-related deaths. Five patients died of disease progression in the 3-month period post-procedure, and the 3-month dysfunction-free stent patency rate was 83 %. CONCLUSION : EUS-CDS with a PCSEMS has a high technical and clinical success. Adverse events were infrequent, minor and could be managed easily.
format Online
Article
Text
id pubmed-5770273
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher © Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-57702732018-01-17 Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP Rai, Praveer Lokesh, CR Goel, Amit Aggarwal, Rakesh Endosc Int Open BACKGROUND AND STUDY AIMS : Endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) is an alternative to percutaneous transhepatic biliary drainage (PTBD) for patients with malignant distal biliary obstruction in whom ERCP has failed. We studied technical success, clinical success, stent patency rate and occurrence of adverse events in patients undergoing EUS-CDS with partially-covered self-expanding metal stent (PCSEMS). PATIENTS AND METHODS : Medical records of consecutive patients with unresectable malignant distal biliary obstruction requiring biliary drainage who underwent EUS-CDS because of failure of attempt at ERCP were reviewed. EUS-CDS was done using 6-cm, PCSEMS (Wallflex, Boston Scientific). Technical success, clinical success (more than 50 % reduction in total bilirubin at 2 weeks post-procedure), stent patency rate and adverse events (AEs) were assessed. Patients were followed up for 3 months post-procedure. RESULTS : Between January 2015 and December 2016, 30 patients underwent EUS-CDS, including 20 (67 %) with failed biliary cannulation and 10 (33 %) with duodenal stenosis. Technical success was achieved in 28 patients, all of whom also had clinical success. Median total serum bilirubin decreased from 20 mg/dL to 5 mg/dL at 2 weeks post-procedure. Three patients (10 %) had adverse events (bile leak, hemobilia, stent block in one patient each; no stent migration); none of these adverse events was major and all were managed successfully. There were no procedure-related deaths. Five patients died of disease progression in the 3-month period post-procedure, and the 3-month dysfunction-free stent patency rate was 83 %. CONCLUSION : EUS-CDS with a PCSEMS has a high technical and clinical success. Adverse events were infrequent, minor and could be managed easily. © Georg Thieme Verlag KG 2018-01 2018-01-16 /pmc/articles/PMC5770273/ /pubmed/29344562 http://dx.doi.org/10.1055/s-0043-120664 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Rai, Praveer
Lokesh, CR
Goel, Amit
Aggarwal, Rakesh
Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP
title Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP
title_full Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP
title_fullStr Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP
title_full_unstemmed Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP
title_short Endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ERCP
title_sort endoscopic ultrasound-guided choledochoduodenostomy using partially-covered self-expandable metal stent in patients with malignant distal biliary obstruction and unsuccessful ercp
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5770273/
https://www.ncbi.nlm.nih.gov/pubmed/29344562
http://dx.doi.org/10.1055/s-0043-120664
work_keys_str_mv AT raipraveer endoscopicultrasoundguidedcholedochoduodenostomyusingpartiallycoveredselfexpandablemetalstentinpatientswithmalignantdistalbiliaryobstructionandunsuccessfulercp
AT lokeshcr endoscopicultrasoundguidedcholedochoduodenostomyusingpartiallycoveredselfexpandablemetalstentinpatientswithmalignantdistalbiliaryobstructionandunsuccessfulercp
AT goelamit endoscopicultrasoundguidedcholedochoduodenostomyusingpartiallycoveredselfexpandablemetalstentinpatientswithmalignantdistalbiliaryobstructionandunsuccessfulercp
AT aggarwalrakesh endoscopicultrasoundguidedcholedochoduodenostomyusingpartiallycoveredselfexpandablemetalstentinpatientswithmalignantdistalbiliaryobstructionandunsuccessfulercp