Cargando…

Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study

BACKGROUND/AIMS: To develop a standardised grading scheme, using standard photos, for spectral-domain ocular coherence tomography (SD-OCT) images of the posterior eye and evaluate the interobserver agreement among trained ophthalmologists in identifying pathological changes. METHODS: Subjects were r...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Sean K, Guo, Xinxing, Xiao, Ou, Chen, Yanxian, Liu, Ran, Huang, Wenyong, He, Mingguang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5770917/
https://www.ncbi.nlm.nih.gov/pubmed/29275341
http://dx.doi.org/10.1136/bmjopen-2017-017923
_version_ 1783293161352724480
author Wang, Sean K
Guo, Xinxing
Xiao, Ou
Chen, Yanxian
Liu, Ran
Huang, Wenyong
He, Mingguang
author_facet Wang, Sean K
Guo, Xinxing
Xiao, Ou
Chen, Yanxian
Liu, Ran
Huang, Wenyong
He, Mingguang
author_sort Wang, Sean K
collection PubMed
description BACKGROUND/AIMS: To develop a standardised grading scheme, using standard photos, for spectral-domain ocular coherence tomography (SD-OCT) images of the posterior eye and evaluate the interobserver agreement among trained ophthalmologists in identifying pathological changes. METHODS: Subjects were recruited from Liwan District, Guangzhou, with SD-OCT data collection from June 2013 to November 2013 as part of 10-year follow-up visits from the Liwan Eye Study. All subjects underwent SD-OCT imaging of the macula with scanning lines analysed by two ophthalmologists to assess for the presence of 12 different posterior segment lesions. Per cent agreement for each lesion between the graders and quantitative measures of dome-shaped macula (DSM) height and choroidal thickness were calculated. RESULTS: A total of 679 SD-OCT images from 679 subjects were independently evaluated by the two graders. Each of the 12 lesions was successfully graded as present or absent in over 96% of images. For all lesions, per cent agreement between observers was over 90%, ranging from 90.7% for epiretinal membranes and retinal pigment epithelium thickenings to 99.7% for full thickness macular holes and retinal detachments. Quantitative measurements of DSM height and choroidal thickness at three locations of the eye all exhibited intraclass correlation scores between the two graders of greater than 0.9. CONCLUSION: Our study demonstrates high concordance between graders in characterising posterior segment lesions using SD-OCT images, validating the continued use of this imaging modality in the diagnosis of posterior eye disease.
format Online
Article
Text
id pubmed-5770917
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-57709172018-01-19 Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study Wang, Sean K Guo, Xinxing Xiao, Ou Chen, Yanxian Liu, Ran Huang, Wenyong He, Mingguang BMJ Open Ophthalmology BACKGROUND/AIMS: To develop a standardised grading scheme, using standard photos, for spectral-domain ocular coherence tomography (SD-OCT) images of the posterior eye and evaluate the interobserver agreement among trained ophthalmologists in identifying pathological changes. METHODS: Subjects were recruited from Liwan District, Guangzhou, with SD-OCT data collection from June 2013 to November 2013 as part of 10-year follow-up visits from the Liwan Eye Study. All subjects underwent SD-OCT imaging of the macula with scanning lines analysed by two ophthalmologists to assess for the presence of 12 different posterior segment lesions. Per cent agreement for each lesion between the graders and quantitative measures of dome-shaped macula (DSM) height and choroidal thickness were calculated. RESULTS: A total of 679 SD-OCT images from 679 subjects were independently evaluated by the two graders. Each of the 12 lesions was successfully graded as present or absent in over 96% of images. For all lesions, per cent agreement between observers was over 90%, ranging from 90.7% for epiretinal membranes and retinal pigment epithelium thickenings to 99.7% for full thickness macular holes and retinal detachments. Quantitative measurements of DSM height and choroidal thickness at three locations of the eye all exhibited intraclass correlation scores between the two graders of greater than 0.9. CONCLUSION: Our study demonstrates high concordance between graders in characterising posterior segment lesions using SD-OCT images, validating the continued use of this imaging modality in the diagnosis of posterior eye disease. BMJ Publishing Group 2017-12-22 /pmc/articles/PMC5770917/ /pubmed/29275341 http://dx.doi.org/10.1136/bmjopen-2017-017923 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Ophthalmology
Wang, Sean K
Guo, Xinxing
Xiao, Ou
Chen, Yanxian
Liu, Ran
Huang, Wenyong
He, Mingguang
Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study
title Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study
title_full Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study
title_fullStr Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study
title_full_unstemmed Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study
title_short Qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the Liwan Eye Study
title_sort qualitative and quantitative assessment of posterior segment optical coherence tomography images using standard photos: the liwan eye study
topic Ophthalmology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5770917/
https://www.ncbi.nlm.nih.gov/pubmed/29275341
http://dx.doi.org/10.1136/bmjopen-2017-017923
work_keys_str_mv AT wangseank qualitativeandquantitativeassessmentofposteriorsegmentopticalcoherencetomographyimagesusingstandardphotostheliwaneyestudy
AT guoxinxing qualitativeandquantitativeassessmentofposteriorsegmentopticalcoherencetomographyimagesusingstandardphotostheliwaneyestudy
AT xiaoou qualitativeandquantitativeassessmentofposteriorsegmentopticalcoherencetomographyimagesusingstandardphotostheliwaneyestudy
AT chenyanxian qualitativeandquantitativeassessmentofposteriorsegmentopticalcoherencetomographyimagesusingstandardphotostheliwaneyestudy
AT liuran qualitativeandquantitativeassessmentofposteriorsegmentopticalcoherencetomographyimagesusingstandardphotostheliwaneyestudy
AT huangwenyong qualitativeandquantitativeassessmentofposteriorsegmentopticalcoherencetomographyimagesusingstandardphotostheliwaneyestudy
AT hemingguang qualitativeandquantitativeassessmentofposteriorsegmentopticalcoherencetomographyimagesusingstandardphotostheliwaneyestudy