The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study()
OBJECTIVE: Synthetic adhesives are used by various medical specialties, especially in surgery; however, studies reporting their use in orthopedic practice are scarce. The aim of this study was to compare the results in using ethyl-2-cyanoacrylate or butyl-2-cyanoacrylate in the treatment of fracture...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5771781/ https://www.ncbi.nlm.nih.gov/pubmed/29367907 http://dx.doi.org/10.1016/j.rboe.2017.11.010 |
_version_ | 1783293309417947136 |
---|---|
author | Palacio, Evandro Pereira Pereira, Gilberto José Cação Silvares, Paulo Roberto de Almeida Stasi, Gabriel Guimarães Di Staut, Caio de Andrade Sardenberg, Trajano |
author_facet | Palacio, Evandro Pereira Pereira, Gilberto José Cação Silvares, Paulo Roberto de Almeida Stasi, Gabriel Guimarães Di Staut, Caio de Andrade Sardenberg, Trajano |
author_sort | Palacio, Evandro Pereira |
collection | PubMed |
description | OBJECTIVE: Synthetic adhesives are used by various medical specialties, especially in surgery; however, studies reporting their use in orthopedic practice are scarce. The aim of this study was to compare the results in using ethyl-2-cyanoacrylate or butyl-2-cyanoacrylate in the treatment of fractures in rats. METHODS: This was an experimental prospective controlled study in 90 rats, with humerus, femur, and tibia fractures, treated with ethyl-2-cyanoacrylate (SB group; n = 45) or butyl-2-cyanoacrylate (HA group; n = 45). Biomechanical and histomorphometric analyses were performed at three different moments (60, 120, and 180 days); besides a clinical study performed weekly by measurement of the animals body mass. RESULTS: No differences were observed regarding body mass (p = 0.07). In both groups, there were no significant differences regarding maximum load (p = 0.6), yield point strength (p = 0.6), and stiffness coefficient (p = 0.4) of the femurs. The same was observed in tibias for maximum load (p = 0.4), yield point strength (p = 0.7), and stiffness coefficient (p = 0.6). The humerus from both groups had similar bone callus area (p = 0.66). In both groups, there were no statistical differences related to inflammatory cells (p = 0.4), osteoblasts (p = 0.2), and osteoclasts (p = 0.2). CONCLUSION: Ethyl-2-cyanoacrylate was more effective than butyl-2-cyanoacrylate in the treatment of fractures in rats. |
format | Online Article Text |
id | pubmed-5771781 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-57717812018-01-24 The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study() Palacio, Evandro Pereira Pereira, Gilberto José Cação Silvares, Paulo Roberto de Almeida Stasi, Gabriel Guimarães Di Staut, Caio de Andrade Sardenberg, Trajano Rev Bras Ortop Original Article OBJECTIVE: Synthetic adhesives are used by various medical specialties, especially in surgery; however, studies reporting their use in orthopedic practice are scarce. The aim of this study was to compare the results in using ethyl-2-cyanoacrylate or butyl-2-cyanoacrylate in the treatment of fractures in rats. METHODS: This was an experimental prospective controlled study in 90 rats, with humerus, femur, and tibia fractures, treated with ethyl-2-cyanoacrylate (SB group; n = 45) or butyl-2-cyanoacrylate (HA group; n = 45). Biomechanical and histomorphometric analyses were performed at three different moments (60, 120, and 180 days); besides a clinical study performed weekly by measurement of the animals body mass. RESULTS: No differences were observed regarding body mass (p = 0.07). In both groups, there were no significant differences regarding maximum load (p = 0.6), yield point strength (p = 0.6), and stiffness coefficient (p = 0.4) of the femurs. The same was observed in tibias for maximum load (p = 0.4), yield point strength (p = 0.7), and stiffness coefficient (p = 0.6). The humerus from both groups had similar bone callus area (p = 0.66). In both groups, there were no statistical differences related to inflammatory cells (p = 0.4), osteoblasts (p = 0.2), and osteoclasts (p = 0.2). CONCLUSION: Ethyl-2-cyanoacrylate was more effective than butyl-2-cyanoacrylate in the treatment of fractures in rats. Elsevier 2017-12-06 /pmc/articles/PMC5771781/ /pubmed/29367907 http://dx.doi.org/10.1016/j.rboe.2017.11.010 Text en © 2017 Sociedade Brasileira de Ortopedia e Traumatologia. Published by Elsevier Editora Ltda. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Palacio, Evandro Pereira Pereira, Gilberto José Cação Silvares, Paulo Roberto de Almeida Stasi, Gabriel Guimarães Di Staut, Caio de Andrade Sardenberg, Trajano The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study() |
title | The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study() |
title_full | The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study() |
title_fullStr | The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study() |
title_full_unstemmed | The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study() |
title_short | The effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. A controlled experimental study() |
title_sort | effects of ethyl-2-cyanoacrylate and butyl-2-cyanoacrylate in the process of bone healing in rats. a controlled experimental study() |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5771781/ https://www.ncbi.nlm.nih.gov/pubmed/29367907 http://dx.doi.org/10.1016/j.rboe.2017.11.010 |
work_keys_str_mv | AT palacioevandropereira theeffectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT pereiragilbertojosecacao theeffectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT silvarespaulorobertodealmeida theeffectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT stasigabrielguimaraesdi theeffectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT stautcaiodeandrade theeffectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT sardenbergtrajano theeffectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT palacioevandropereira effectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT pereiragilbertojosecacao effectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT silvarespaulorobertodealmeida effectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT stasigabrielguimaraesdi effectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT stautcaiodeandrade effectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy AT sardenbergtrajano effectsofethyl2cyanoacrylateandbutyl2cyanoacrylateintheprocessofbonehealinginratsacontrolledexperimentalstudy |