Cargando…

Evaluation of a Serum Lung Cancer Biomarker Panel

BACKGROUND: A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact o...

Descripción completa

Detalles Bibliográficos
Autores principales: Mazzone, Peter J, Wang, Xiao-Feng, Han, Xiaozhen, Choi, Humberto, Seeley, Meredith, Scherer, Richard, Doseeva, Victoria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5772503/
https://www.ncbi.nlm.nih.gov/pubmed/29371783
http://dx.doi.org/10.1177/1177271917751608
_version_ 1783293424406888448
author Mazzone, Peter J
Wang, Xiao-Feng
Han, Xiaozhen
Choi, Humberto
Seeley, Meredith
Scherer, Richard
Doseeva, Victoria
author_facet Mazzone, Peter J
Wang, Xiao-Feng
Han, Xiaozhen
Choi, Humberto
Seeley, Meredith
Scherer, Richard
Doseeva, Victoria
author_sort Mazzone, Peter J
collection PubMed
description BACKGROUND: A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. METHODS: The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. RESULTS: The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. CONCLUSIONS: This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results.
format Online
Article
Text
id pubmed-5772503
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-57725032018-01-25 Evaluation of a Serum Lung Cancer Biomarker Panel Mazzone, Peter J Wang, Xiao-Feng Han, Xiaozhen Choi, Humberto Seeley, Meredith Scherer, Richard Doseeva, Victoria Biomark Insights Original Research BACKGROUND: A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. METHODS: The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. RESULTS: The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. CONCLUSIONS: This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results. SAGE Publications 2018-01-15 /pmc/articles/PMC5772503/ /pubmed/29371783 http://dx.doi.org/10.1177/1177271917751608 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages(https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Mazzone, Peter J
Wang, Xiao-Feng
Han, Xiaozhen
Choi, Humberto
Seeley, Meredith
Scherer, Richard
Doseeva, Victoria
Evaluation of a Serum Lung Cancer Biomarker Panel
title Evaluation of a Serum Lung Cancer Biomarker Panel
title_full Evaluation of a Serum Lung Cancer Biomarker Panel
title_fullStr Evaluation of a Serum Lung Cancer Biomarker Panel
title_full_unstemmed Evaluation of a Serum Lung Cancer Biomarker Panel
title_short Evaluation of a Serum Lung Cancer Biomarker Panel
title_sort evaluation of a serum lung cancer biomarker panel
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5772503/
https://www.ncbi.nlm.nih.gov/pubmed/29371783
http://dx.doi.org/10.1177/1177271917751608
work_keys_str_mv AT mazzonepeterj evaluationofaserumlungcancerbiomarkerpanel
AT wangxiaofeng evaluationofaserumlungcancerbiomarkerpanel
AT hanxiaozhen evaluationofaserumlungcancerbiomarkerpanel
AT choihumberto evaluationofaserumlungcancerbiomarkerpanel
AT seeleymeredith evaluationofaserumlungcancerbiomarkerpanel
AT schererrichard evaluationofaserumlungcancerbiomarkerpanel
AT doseevavictoria evaluationofaserumlungcancerbiomarkerpanel