Cargando…
Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study
BACKGROUND: The major causes of maternal and neonatal mortality in the Philippines are hemorrhages and obstructed labor due to placental implantation abnormalities (PIAs), twin pregnancies and fetal malpresentations. All of which are all easily detected by ultrasound. However, women in rural areas a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5774122/ https://www.ncbi.nlm.nih.gov/pubmed/29347926 http://dx.doi.org/10.1186/s12884-018-1658-8 |
_version_ | 1783293706080616448 |
---|---|
author | Dalmacion, Godofreda V. Reyles, Ramon T. Habana, Antonia E. Cruz, Lalaine Mae V. Chua, Maricelle C. Ngo, Analyn T. Tia-Jocson, Milagros J. Baja, Emmanuel S. |
author_facet | Dalmacion, Godofreda V. Reyles, Ramon T. Habana, Antonia E. Cruz, Lalaine Mae V. Chua, Maricelle C. Ngo, Analyn T. Tia-Jocson, Milagros J. Baja, Emmanuel S. |
author_sort | Dalmacion, Godofreda V. |
collection | PubMed |
description | BACKGROUND: The major causes of maternal and neonatal mortality in the Philippines are hemorrhages and obstructed labor due to placental implantation abnormalities (PIAs), twin pregnancies and fetal malpresentations. All of which are all easily detected by ultrasound. However, women in rural areas and low-income groups do not have access to ultrasound during their prenatal care. We aimed to provide additional evidence on the benefits of handheld ultrasound (HU) for screening pregnancy related abnormalities in order to avert maternal and neonatal deaths. METHODS: Using a HU, we trained community healthcare workers (CHWs) to identify 5 obstetrical conditions: fetal viability and number, placental localization, amniotic fluid volume (AFV) and fetal presentation. Women, between 20th and 24th weeks age of gestation from 2 regions of the Philippines, were scanned using the HU and the GE Logic 5 Premium ultrasound machine for validation. Maternal and neonatal deaths averted were estimated as health outcome measures of the study. RESULTS: Four hundred sixty women were scanned of which 146 (31.7%) showed abnormal ultrasound readings consisting of 17 PIAs, 123 fetal malpresentation, 3 twins and 3 AFV abnormalities. The use of HU could have possibly averted 29 (6.3%) maternal deaths and 14.6% neonatal deaths at the time of delivery. Thirty-two out of the 460 women (~7%) delivered at home and 93% in hospitals or birthing facilities/lying–in centers. We observed approximately 95% agreement between the ultrasound readings of the trainees and the trainers, and 99% agreement between the readings made from the HU with the validation machine. CONCLUSION: CHWs could be trained in the use of HU for scanning 5 obstetrical parameters. Early detection of abnormalities in these 5 obstetrical parameters can lead to early referral to facilities that are better equipped to manage obstetrical emergencies. Prenatal ultrasound can be an excellent point of care test for screening pregnant women at risk for possible complications and even death during labor and delivery. TRIAL REGISTRATION: Thai Clinical Trial Registry identification number TCTR20171128004, retrospectively registered November 28, 2017. |
format | Online Article Text |
id | pubmed-5774122 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-57741222018-01-26 Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study Dalmacion, Godofreda V. Reyles, Ramon T. Habana, Antonia E. Cruz, Lalaine Mae V. Chua, Maricelle C. Ngo, Analyn T. Tia-Jocson, Milagros J. Baja, Emmanuel S. BMC Pregnancy Childbirth Research Article BACKGROUND: The major causes of maternal and neonatal mortality in the Philippines are hemorrhages and obstructed labor due to placental implantation abnormalities (PIAs), twin pregnancies and fetal malpresentations. All of which are all easily detected by ultrasound. However, women in rural areas and low-income groups do not have access to ultrasound during their prenatal care. We aimed to provide additional evidence on the benefits of handheld ultrasound (HU) for screening pregnancy related abnormalities in order to avert maternal and neonatal deaths. METHODS: Using a HU, we trained community healthcare workers (CHWs) to identify 5 obstetrical conditions: fetal viability and number, placental localization, amniotic fluid volume (AFV) and fetal presentation. Women, between 20th and 24th weeks age of gestation from 2 regions of the Philippines, were scanned using the HU and the GE Logic 5 Premium ultrasound machine for validation. Maternal and neonatal deaths averted were estimated as health outcome measures of the study. RESULTS: Four hundred sixty women were scanned of which 146 (31.7%) showed abnormal ultrasound readings consisting of 17 PIAs, 123 fetal malpresentation, 3 twins and 3 AFV abnormalities. The use of HU could have possibly averted 29 (6.3%) maternal deaths and 14.6% neonatal deaths at the time of delivery. Thirty-two out of the 460 women (~7%) delivered at home and 93% in hospitals or birthing facilities/lying–in centers. We observed approximately 95% agreement between the ultrasound readings of the trainees and the trainers, and 99% agreement between the readings made from the HU with the validation machine. CONCLUSION: CHWs could be trained in the use of HU for scanning 5 obstetrical parameters. Early detection of abnormalities in these 5 obstetrical parameters can lead to early referral to facilities that are better equipped to manage obstetrical emergencies. Prenatal ultrasound can be an excellent point of care test for screening pregnant women at risk for possible complications and even death during labor and delivery. TRIAL REGISTRATION: Thai Clinical Trial Registry identification number TCTR20171128004, retrospectively registered November 28, 2017. BioMed Central 2018-01-18 /pmc/articles/PMC5774122/ /pubmed/29347926 http://dx.doi.org/10.1186/s12884-018-1658-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Dalmacion, Godofreda V. Reyles, Ramon T. Habana, Antonia E. Cruz, Lalaine Mae V. Chua, Maricelle C. Ngo, Analyn T. Tia-Jocson, Milagros J. Baja, Emmanuel S. Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study |
title | Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study |
title_full | Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study |
title_fullStr | Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study |
title_full_unstemmed | Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study |
title_short | Handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the Philippines: an iBuntis® intervention study |
title_sort | handheld ultrasound to avert maternal and neonatal deaths in 2 regions of the philippines: an ibuntis® intervention study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5774122/ https://www.ncbi.nlm.nih.gov/pubmed/29347926 http://dx.doi.org/10.1186/s12884-018-1658-8 |
work_keys_str_mv | AT dalmaciongodofredav handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy AT reylesramont handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy AT habanaantoniae handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy AT cruzlalainemaev handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy AT chuamaricellec handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy AT ngoanalynt handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy AT tiajocsonmilagrosj handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy AT bajaemmanuels handheldultrasoundtoavertmaternalandneonataldeathsin2regionsofthephilippinesanibuntisinterventionstudy |