Cargando…
Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases
Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5774517/ https://www.ncbi.nlm.nih.gov/pubmed/29399356 http://dx.doi.org/10.3892/mco.2017.1515 |
_version_ | 1783293770810261504 |
---|---|
author | Tanisaka, Yuki Ryozawa, Shomei Kobayashi, Masanori Harada, Maiko Kobatake, Tsutomu Omiya, Kumiko Iwano, Hirotoshi Arai, Shin Nonaka, Kouichi Mashimo, Yumi |
author_facet | Tanisaka, Yuki Ryozawa, Shomei Kobayashi, Masanori Harada, Maiko Kobatake, Tsutomu Omiya, Kumiko Iwano, Hirotoshi Arai, Shin Nonaka, Kouichi Mashimo, Yumi |
author_sort | Tanisaka, Yuki |
collection | PubMed |
description | Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117–205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5–24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed. |
format | Online Article Text |
id | pubmed-5774517 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-57745172018-02-02 Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases Tanisaka, Yuki Ryozawa, Shomei Kobayashi, Masanori Harada, Maiko Kobatake, Tsutomu Omiya, Kumiko Iwano, Hirotoshi Arai, Shin Nonaka, Kouichi Mashimo, Yumi Mol Clin Oncol Articles Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117–205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5–24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed. D.A. Spandidos 2018-02 2017-11-27 /pmc/articles/PMC5774517/ /pubmed/29399356 http://dx.doi.org/10.3892/mco.2017.1515 Text en Copyright: © Tanisaka et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Tanisaka, Yuki Ryozawa, Shomei Kobayashi, Masanori Harada, Maiko Kobatake, Tsutomu Omiya, Kumiko Iwano, Hirotoshi Arai, Shin Nonaka, Kouichi Mashimo, Yumi Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases |
title | Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases |
title_full | Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases |
title_fullStr | Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases |
title_full_unstemmed | Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases |
title_short | Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases |
title_sort | endoscopic removal of laser-cut covered self-expandable metallic biliary stents: a report of six cases |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5774517/ https://www.ncbi.nlm.nih.gov/pubmed/29399356 http://dx.doi.org/10.3892/mco.2017.1515 |
work_keys_str_mv | AT tanisakayuki endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT ryozawashomei endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT kobayashimasanori endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT haradamaiko endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT kobataketsutomu endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT omiyakumiko endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT iwanohirotoshi endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT araishin endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT nonakakouichi endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases AT mashimoyumi endoscopicremovaloflasercutcoveredselfexpandablemetallicbiliarystentsareportofsixcases |