Cargando…
A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain
BACKGROUND: Magnetocardiography (MCG) is a non-invasive technique used to measure and map cardiac magnetic fields. We describe the predictive performance of a portable prototype magnetometer designed for use in acute and routine clinical settings. We assessed the predictive ability of the measuremen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5774725/ https://www.ncbi.nlm.nih.gov/pubmed/29351337 http://dx.doi.org/10.1371/journal.pone.0191241 |
_version_ | 1783293796529733632 |
---|---|
author | Ghasemi-Roudsari, Shima Al-Shimary, Abbas Varcoe, Benjamin Byrom, Rowena Kearney, Lorraine Kearney, Mark |
author_facet | Ghasemi-Roudsari, Shima Al-Shimary, Abbas Varcoe, Benjamin Byrom, Rowena Kearney, Lorraine Kearney, Mark |
author_sort | Ghasemi-Roudsari, Shima |
collection | PubMed |
description | BACKGROUND: Magnetocardiography (MCG) is a non-invasive technique used to measure and map cardiac magnetic fields. We describe the predictive performance of a portable prototype magnetometer designed for use in acute and routine clinical settings. We assessed the predictive ability of the measurements derived from the magnetometer for the ruling-out of healthy subjects and patients whose chest pain has a non-ischemic origin from those with ischemic heart disease (IHD). METHODS: MCG data were analyzed from a technical performance study, a pilot clinical study, and a young healthy reference group. Participants were grouped to enable differentiation of those with IHD versus non-IHD versus controls: Group A (70 IHD patients); Group B (69 controls); Group C (37 young healthy volunteers). Scans were recorded in an unshielded room. Between-group differences were explored using analysis of variance. The ability of 10 candidate MCG predictors to predict normal/abnormal cases was analyzed using logistic regression. Predictive performance was internally validated using repeated five-fold cross-validation. RESULTS: Three MCG predictors showed a significant difference between patients and age-matched controls (P<0.001); eight predictors showed a significant difference between patients and young healthy volunteers (P<0.001). Logistic regression comparing patients with controls yielded a specificity of 35.0%, sensitivity of 95.4%, and negative predictive value for the ruling-out of IHD of 97.8% (area under the curve 0.78). CONCLUSION: This analysis represents a preliminary indication that the portable magnetometer can help rule-out healthy subjects and patients whose chest pain has a non-ischemic origin from those with IHD. |
format | Online Article Text |
id | pubmed-5774725 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-57747252018-02-05 A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain Ghasemi-Roudsari, Shima Al-Shimary, Abbas Varcoe, Benjamin Byrom, Rowena Kearney, Lorraine Kearney, Mark PLoS One Research Article BACKGROUND: Magnetocardiography (MCG) is a non-invasive technique used to measure and map cardiac magnetic fields. We describe the predictive performance of a portable prototype magnetometer designed for use in acute and routine clinical settings. We assessed the predictive ability of the measurements derived from the magnetometer for the ruling-out of healthy subjects and patients whose chest pain has a non-ischemic origin from those with ischemic heart disease (IHD). METHODS: MCG data were analyzed from a technical performance study, a pilot clinical study, and a young healthy reference group. Participants were grouped to enable differentiation of those with IHD versus non-IHD versus controls: Group A (70 IHD patients); Group B (69 controls); Group C (37 young healthy volunteers). Scans were recorded in an unshielded room. Between-group differences were explored using analysis of variance. The ability of 10 candidate MCG predictors to predict normal/abnormal cases was analyzed using logistic regression. Predictive performance was internally validated using repeated five-fold cross-validation. RESULTS: Three MCG predictors showed a significant difference between patients and age-matched controls (P<0.001); eight predictors showed a significant difference between patients and young healthy volunteers (P<0.001). Logistic regression comparing patients with controls yielded a specificity of 35.0%, sensitivity of 95.4%, and negative predictive value for the ruling-out of IHD of 97.8% (area under the curve 0.78). CONCLUSION: This analysis represents a preliminary indication that the portable magnetometer can help rule-out healthy subjects and patients whose chest pain has a non-ischemic origin from those with IHD. Public Library of Science 2018-01-19 /pmc/articles/PMC5774725/ /pubmed/29351337 http://dx.doi.org/10.1371/journal.pone.0191241 Text en © 2018 Ghasemi-Roudsari et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Ghasemi-Roudsari, Shima Al-Shimary, Abbas Varcoe, Benjamin Byrom, Rowena Kearney, Lorraine Kearney, Mark A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain |
title | A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain |
title_full | A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain |
title_fullStr | A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain |
title_full_unstemmed | A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain |
title_short | A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain |
title_sort | portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5774725/ https://www.ncbi.nlm.nih.gov/pubmed/29351337 http://dx.doi.org/10.1371/journal.pone.0191241 |
work_keys_str_mv | AT ghasemiroudsarishima aportableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT alshimaryabbas aportableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT varcoebenjamin aportableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT byromrowena aportableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT kearneylorraine aportableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT kearneymark aportableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT ghasemiroudsarishima portableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT alshimaryabbas portableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT varcoebenjamin portableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT byromrowena portableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT kearneylorraine portableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain AT kearneymark portableprototypemagnetometertodifferentiateischemicandnonischemicheartdiseaseinpatientswithchestpain |