A novel hypothermic machine perfusion system using a LifePort Kidney Transporter for the preservation of rat liver
The protective mechanisms for liver preservation associated with hypothermic machine perfusion (HMP) remain unclear. However, the lack of a common and portable HMP system for rat livers limits the study of HMP. The present study aimed to develop a novel, modified HMP system using a LifePort Kidney T...
Autores principales: | Zeng, Cheng, Hu, Xiaoyan, Wang, Yanfeng, Zeng, Xianpeng, Xiong, Yan, Li, Ling, Ye, Qifa |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5776655/ https://www.ncbi.nlm.nih.gov/pubmed/29434725 http://dx.doi.org/10.3892/etm.2017.5587 |
Ejemplares similares
-
Appropriate timing for hypothermic machine perfusion to preserve livers donated after circulatory death
por: Hu, Xiaoyan, et al.
Publicado: (2020) -
Hypothermic machine perfusion attenuates ischemia/reperfusion injury against rat livers donated after cardiac death by activating the Keap1/Nrf2-ARE signaling pathway
por: Xue, Shuai, et al.
Publicado: (2018) -
Hypothermic Machine Perfusion Preservation of the DCD Kidney: Machine Effects
por: Lindell, Susanne L., et al.
Publicado: (2013) -
Hypothermic machine perfusion ameliorates inflammation during ischemia-reperfusion injury via sirtuin-1-mediated deacetylation of nuclear factor-κB p65 in rat livers donated after circulatory death
por: Zeng, Cheng, et al.
Publicado: (2017) -
Trends and Outcomes of Hypothermic Machine Perfusion Preservation of Kidney Allografts in Simultaneous Liver and Kidney Transplantation in the United States
por: Chang, Alex, et al.