Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings

The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings. MATERIAL AND METHODS: Sixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using differen...

Descripción completa

Detalles Bibliográficos
Autores principales: Rudolph, Heike, Ostertag, Silke, Ostertag, Michael, Walter, Michael H., LUTHARDT, Ralph Gunnar, Kuhn, Katharina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade De Odontologia De Bauru - USP 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5777408/
https://www.ncbi.nlm.nih.gov/pubmed/29412364
http://dx.doi.org/10.1590/1678-7757-2016-0590
_version_ 1783294191835545600
author Rudolph, Heike
Ostertag, Silke
Ostertag, Michael
Walter, Michael H.
LUTHARDT, Ralph Gunnar
Kuhn, Katharina
author_facet Rudolph, Heike
Ostertag, Silke
Ostertag, Michael
Walter, Michael H.
LUTHARDT, Ralph Gunnar
Kuhn, Katharina
author_sort Rudolph, Heike
collection PubMed
description The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings. MATERIAL AND METHODS: Sixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using different parameters (data density; enlargement in different directions), varying fit was created. Five light-body silicone replicas representing the gap between the canine and the coping were made for each coping and for each measurement method: (1) light microscopy measurements (LMMs); and (2) computer-assisted measurements (CASMs) using an optical digitizing system. Two investigators independently measured the marginal and internal fit using both methods. The inter-rater reliability [intraclass correlation coefficient (ICC)] and agreement [Bland-Altman (bias) analyses]: mean of the differences (bias) between two measurements [the closer to zero the mean (bias) is, the higher the agreement between the two measurements] were calculated for several measurement points (marginal-distal, marginal-buccal, axial-buccal, incisal). For the LMM technique, one investigator repeated the measurements to determine repeatability (intra-rater reliability and agreement). RESULTS: For inter-rater reliability, the ICC was 0.848-0.998 for LMMs and 0.945-0.999 for CASMs, depending on the measurement point. Bland-Altman bias was −15.7 to 3.5 μm for LMMs and −3.0 to 1.9 μm for CASMs. For LMMs, the marginal-distal and marginal-buccal measurement points showed the lowest ICC (0.848/0.978) and the highest bias (-15.7 μm/-7.6 μm). With the intra-rater reliability and agreement (repeatability) for LMMs, the ICC was 0.970-0.998 and bias was −1.3 to 2.3 μm. CONCLUSION: LMMs showed lower interrater reliability and agreement at the marginal measurement points than CASMs, which indicates a more subjective influence with LMMs at these measurement points. The values, however, were still clinically acceptable. LMMs showed very high intra-rater reliability and agreement for all measurement points, indicating high repeatability.
format Online
Article
Text
id pubmed-5777408
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Faculdade De Odontologia De Bauru - USP
record_format MEDLINE/PubMed
spelling pubmed-57774082018-01-24 Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings Rudolph, Heike Ostertag, Silke Ostertag, Michael Walter, Michael H. LUTHARDT, Ralph Gunnar Kuhn, Katharina J Appl Oral Sci Original Articles The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings. MATERIAL AND METHODS: Sixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using different parameters (data density; enlargement in different directions), varying fit was created. Five light-body silicone replicas representing the gap between the canine and the coping were made for each coping and for each measurement method: (1) light microscopy measurements (LMMs); and (2) computer-assisted measurements (CASMs) using an optical digitizing system. Two investigators independently measured the marginal and internal fit using both methods. The inter-rater reliability [intraclass correlation coefficient (ICC)] and agreement [Bland-Altman (bias) analyses]: mean of the differences (bias) between two measurements [the closer to zero the mean (bias) is, the higher the agreement between the two measurements] were calculated for several measurement points (marginal-distal, marginal-buccal, axial-buccal, incisal). For the LMM technique, one investigator repeated the measurements to determine repeatability (intra-rater reliability and agreement). RESULTS: For inter-rater reliability, the ICC was 0.848-0.998 for LMMs and 0.945-0.999 for CASMs, depending on the measurement point. Bland-Altman bias was −15.7 to 3.5 μm for LMMs and −3.0 to 1.9 μm for CASMs. For LMMs, the marginal-distal and marginal-buccal measurement points showed the lowest ICC (0.848/0.978) and the highest bias (-15.7 μm/-7.6 μm). With the intra-rater reliability and agreement (repeatability) for LMMs, the ICC was 0.970-0.998 and bias was −1.3 to 2.3 μm. CONCLUSION: LMMs showed lower interrater reliability and agreement at the marginal measurement points than CASMs, which indicates a more subjective influence with LMMs at these measurement points. The values, however, were still clinically acceptable. LMMs showed very high intra-rater reliability and agreement for all measurement points, indicating high repeatability. Faculdade De Odontologia De Bauru - USP 2018-01-16 /pmc/articles/PMC5777408/ /pubmed/29412364 http://dx.doi.org/10.1590/1678-7757-2016-0590 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Rudolph, Heike
Ostertag, Silke
Ostertag, Michael
Walter, Michael H.
LUTHARDT, Ralph Gunnar
Kuhn, Katharina
Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
title Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
title_full Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
title_fullStr Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
title_full_unstemmed Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
title_short Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
title_sort reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5777408/
https://www.ncbi.nlm.nih.gov/pubmed/29412364
http://dx.doi.org/10.1590/1678-7757-2016-0590
work_keys_str_mv AT rudolphheike reliabilityoflightmicroscopyandacomputerassistedreplicameasurementtechniqueforevaluatingthefitofdentalcopings
AT ostertagsilke reliabilityoflightmicroscopyandacomputerassistedreplicameasurementtechniqueforevaluatingthefitofdentalcopings
AT ostertagmichael reliabilityoflightmicroscopyandacomputerassistedreplicameasurementtechniqueforevaluatingthefitofdentalcopings
AT waltermichaelh reliabilityoflightmicroscopyandacomputerassistedreplicameasurementtechniqueforevaluatingthefitofdentalcopings
AT luthardtralphgunnar reliabilityoflightmicroscopyandacomputerassistedreplicameasurementtechniqueforevaluatingthefitofdentalcopings
AT kuhnkatharina reliabilityoflightmicroscopyandacomputerassistedreplicameasurementtechniqueforevaluatingthefitofdentalcopings