Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics

PURPOSE: To compare the computed optical performance of prototype lenses designed using deliberate manipulation of higher-order spherical aberrations to extend depth-of-focus (EDOF) with two commercial multifocals. METHODS: Emmetropic, presbyopic, schematic eyes were coupled with prototype EDOF and...

Descripción completa

Detalles Bibliográficos
Autores principales: Bakaraju, Ravi C., Ehrmann, Klaus, Ho, Arthur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5777930/
https://www.ncbi.nlm.nih.gov/pubmed/28606456
http://dx.doi.org/10.1016/j.optom.2017.04.003
_version_ 1783294261660221440
author Bakaraju, Ravi C.
Ehrmann, Klaus
Ho, Arthur
author_facet Bakaraju, Ravi C.
Ehrmann, Klaus
Ho, Arthur
author_sort Bakaraju, Ravi C.
collection PubMed
description PURPOSE: To compare the computed optical performance of prototype lenses designed using deliberate manipulation of higher-order spherical aberrations to extend depth-of-focus (EDOF) with two commercial multifocals. METHODS: Emmetropic, presbyopic, schematic eyes were coupled with prototype EDOF and commercial multifocal lenses (Acuvue Oasys for presbyopia, AOP, Johnson & Johnson & Air Optix Aqua multifocal, AOMF, Alcon). For each test configuration, the through-focus retinal image quality (TFRIQ) values were computed over 21 vergences, ranging from −0.50 to 2.00 D, in 0.125 D steps. Analysis was performed considering eyes with three different inherent aberration profiles: five different pupils and five different lens decentration levels. RESULTS: Except the LOW design, the AOP lenses offered ‘bifocal’ like TFRIQ performance. Lens performance was relatively independent to pupil and aberrations but not centration. Contrastingly, AOMF demonstrated distance centric performance, most dominant in LOW followed by MED and HIGH designs. AOMF lenses were the most sensitive to pupil, aberrations and centration. The prototypes demonstrated a ‘lift-off’ in the TFRIQ performance, particularly at intermediate and near, without trading performance at distance. When compared with AOP and AOMF, EDOF lenses demonstrated reduced sensitivity to pupil, aberrations and centration. CONCLUSION: With the through focus retinal image quality as the gauge of optical performance, we demonstrated that the prototype EDOF designs were less susceptible to variations in pupil, inherent ocular aberrations and decentration, compared to the commercial designs. To ascertain whether these incremental improvements translate to a clinically palpable outcome requires investigation through human trials.
format Online
Article
Text
id pubmed-5777930
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-57779302018-01-29 Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics Bakaraju, Ravi C. Ehrmann, Klaus Ho, Arthur J Optom Original article PURPOSE: To compare the computed optical performance of prototype lenses designed using deliberate manipulation of higher-order spherical aberrations to extend depth-of-focus (EDOF) with two commercial multifocals. METHODS: Emmetropic, presbyopic, schematic eyes were coupled with prototype EDOF and commercial multifocal lenses (Acuvue Oasys for presbyopia, AOP, Johnson & Johnson & Air Optix Aqua multifocal, AOMF, Alcon). For each test configuration, the through-focus retinal image quality (TFRIQ) values were computed over 21 vergences, ranging from −0.50 to 2.00 D, in 0.125 D steps. Analysis was performed considering eyes with three different inherent aberration profiles: five different pupils and five different lens decentration levels. RESULTS: Except the LOW design, the AOP lenses offered ‘bifocal’ like TFRIQ performance. Lens performance was relatively independent to pupil and aberrations but not centration. Contrastingly, AOMF demonstrated distance centric performance, most dominant in LOW followed by MED and HIGH designs. AOMF lenses were the most sensitive to pupil, aberrations and centration. The prototypes demonstrated a ‘lift-off’ in the TFRIQ performance, particularly at intermediate and near, without trading performance at distance. When compared with AOP and AOMF, EDOF lenses demonstrated reduced sensitivity to pupil, aberrations and centration. CONCLUSION: With the through focus retinal image quality as the gauge of optical performance, we demonstrated that the prototype EDOF designs were less susceptible to variations in pupil, inherent ocular aberrations and decentration, compared to the commercial designs. To ascertain whether these incremental improvements translate to a clinically palpable outcome requires investigation through human trials. Elsevier 2018 2017-06-09 /pmc/articles/PMC5777930/ /pubmed/28606456 http://dx.doi.org/10.1016/j.optom.2017.04.003 Text en © 2017 Spanish General Council of Optometry. Published by Elsevier Espa˜na, S.L.U. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original article
Bakaraju, Ravi C.
Ehrmann, Klaus
Ho, Arthur
Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
title Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
title_full Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
title_fullStr Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
title_full_unstemmed Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
title_short Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
title_sort extended depth of focus contact lenses vs. two commercial multifocals: part 1. optical performance evaluation via computed through-focus retinal image quality metrics
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5777930/
https://www.ncbi.nlm.nih.gov/pubmed/28606456
http://dx.doi.org/10.1016/j.optom.2017.04.003
work_keys_str_mv AT bakarajuravic extendeddepthoffocuscontactlensesvstwocommercialmultifocalspart1opticalperformanceevaluationviacomputedthroughfocusretinalimagequalitymetrics
AT ehrmannklaus extendeddepthoffocuscontactlensesvstwocommercialmultifocalspart1opticalperformanceevaluationviacomputedthroughfocusretinalimagequalitymetrics
AT hoarthur extendeddepthoffocuscontactlensesvstwocommercialmultifocalspart1opticalperformanceevaluationviacomputedthroughfocusretinalimagequalitymetrics