Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy

The microdosimetric kinetic model (MKM) is widely used for estimating relative biological effectiveness (RBE)-weighted doses for various radiotherapies because it can determine the surviving fraction of irradiated cells based on only the lineal energy distribution, and it is independent of the radia...

Descripción completa

Detalles Bibliográficos
Autores principales: Takada, Kenta, Sato, Tatsuhiko, Kumada, Hiroaki, Koketsu, Junichi, Takei, Hideyuki, Sakurai, Hideyuki, Sakae, Takeji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5778494/
https://www.ncbi.nlm.nih.gov/pubmed/29087492
http://dx.doi.org/10.1093/jrr/rrx057
_version_ 1783294363580760064
author Takada, Kenta
Sato, Tatsuhiko
Kumada, Hiroaki
Koketsu, Junichi
Takei, Hideyuki
Sakurai, Hideyuki
Sakae, Takeji
author_facet Takada, Kenta
Sato, Tatsuhiko
Kumada, Hiroaki
Koketsu, Junichi
Takei, Hideyuki
Sakurai, Hideyuki
Sakae, Takeji
author_sort Takada, Kenta
collection PubMed
description The microdosimetric kinetic model (MKM) is widely used for estimating relative biological effectiveness (RBE)-weighted doses for various radiotherapies because it can determine the surviving fraction of irradiated cells based on only the lineal energy distribution, and it is independent of the radiation type and ion species. However, the applicability of the method to proton therapy has not yet been investigated thoroughly. In this study, we validated the RBE-weighted dose calculated by the MKM in tandem with the Monte Carlo code PHITS for proton therapy by considering the complete simulation geometry of the clinical proton beam line. The physical dose, lineal energy distribution, and RBE-weighted dose for a 155 MeV mono-energetic and spread-out Bragg peak (SOBP) beam of 60 mm width were evaluated. In estimating the physical dose, the calculated depth dose distribution by irradiating the mono-energetic beam using PHITS was consistent with the data measured by a diode detector. A maximum difference of 3.1% in the depth distribution was observed for the SOBP beam. In the RBE-weighted dose validation, the calculated lineal energy distributions generally agreed well with the published measurement data. The calculated and measured RBE-weighted doses were in excellent agreement, except at the Bragg peak region of the mono-energetic beam, where the calculation overestimated the measured data by ~15%. This research has provided a computational microdosimetric approach based on a combination of PHITS and MKM for typical clinical proton beams. The developed RBE-estimator function has potential application in the treatment planning system for various radiotherapies.
format Online
Article
Text
id pubmed-5778494
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-57784942018-01-30 Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy Takada, Kenta Sato, Tatsuhiko Kumada, Hiroaki Koketsu, Junichi Takei, Hideyuki Sakurai, Hideyuki Sakae, Takeji J Radiat Res Regular Paper The microdosimetric kinetic model (MKM) is widely used for estimating relative biological effectiveness (RBE)-weighted doses for various radiotherapies because it can determine the surviving fraction of irradiated cells based on only the lineal energy distribution, and it is independent of the radiation type and ion species. However, the applicability of the method to proton therapy has not yet been investigated thoroughly. In this study, we validated the RBE-weighted dose calculated by the MKM in tandem with the Monte Carlo code PHITS for proton therapy by considering the complete simulation geometry of the clinical proton beam line. The physical dose, lineal energy distribution, and RBE-weighted dose for a 155 MeV mono-energetic and spread-out Bragg peak (SOBP) beam of 60 mm width were evaluated. In estimating the physical dose, the calculated depth dose distribution by irradiating the mono-energetic beam using PHITS was consistent with the data measured by a diode detector. A maximum difference of 3.1% in the depth distribution was observed for the SOBP beam. In the RBE-weighted dose validation, the calculated lineal energy distributions generally agreed well with the published measurement data. The calculated and measured RBE-weighted doses were in excellent agreement, except at the Bragg peak region of the mono-energetic beam, where the calculation overestimated the measured data by ~15%. This research has provided a computational microdosimetric approach based on a combination of PHITS and MKM for typical clinical proton beams. The developed RBE-estimator function has potential application in the treatment planning system for various radiotherapies. Oxford University Press 2018-01 2017-10-26 /pmc/articles/PMC5778494/ /pubmed/29087492 http://dx.doi.org/10.1093/jrr/rrx057 Text en © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Regular Paper
Takada, Kenta
Sato, Tatsuhiko
Kumada, Hiroaki
Koketsu, Junichi
Takei, Hideyuki
Sakurai, Hideyuki
Sakae, Takeji
Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy
title Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy
title_full Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy
title_fullStr Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy
title_full_unstemmed Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy
title_short Validation of the physical and RBE-weighted dose estimator based on PHITS coupled with a microdosimetric kinetic model for proton therapy
title_sort validation of the physical and rbe-weighted dose estimator based on phits coupled with a microdosimetric kinetic model for proton therapy
topic Regular Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5778494/
https://www.ncbi.nlm.nih.gov/pubmed/29087492
http://dx.doi.org/10.1093/jrr/rrx057
work_keys_str_mv AT takadakenta validationofthephysicalandrbeweighteddoseestimatorbasedonphitscoupledwithamicrodosimetrickineticmodelforprotontherapy
AT satotatsuhiko validationofthephysicalandrbeweighteddoseestimatorbasedonphitscoupledwithamicrodosimetrickineticmodelforprotontherapy
AT kumadahiroaki validationofthephysicalandrbeweighteddoseestimatorbasedonphitscoupledwithamicrodosimetrickineticmodelforprotontherapy
AT koketsujunichi validationofthephysicalandrbeweighteddoseestimatorbasedonphitscoupledwithamicrodosimetrickineticmodelforprotontherapy
AT takeihideyuki validationofthephysicalandrbeweighteddoseestimatorbasedonphitscoupledwithamicrodosimetrickineticmodelforprotontherapy
AT sakuraihideyuki validationofthephysicalandrbeweighteddoseestimatorbasedonphitscoupledwithamicrodosimetrickineticmodelforprotontherapy
AT sakaetakeji validationofthephysicalandrbeweighteddoseestimatorbasedonphitscoupledwithamicrodosimetrickineticmodelforprotontherapy