Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes
PURPOSE: The aim of this study is to investigate the efficacy and safety of needling-revision augmented with a high dose of mitomycin C (MMC) in failing or failed blebs after trabeculectomy in Indian eyes. METHODS: Prospective, noncomparative, interventional study. All patients (>18 years) who ha...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5778587/ https://www.ncbi.nlm.nih.gov/pubmed/29283127 http://dx.doi.org/10.4103/ijo.IJO_523_17 |
_version_ | 1783294379982585856 |
---|---|
author | Pathak-Ray, Vanita Choudhari, Nikhil |
author_facet | Pathak-Ray, Vanita Choudhari, Nikhil |
author_sort | Pathak-Ray, Vanita |
collection | PubMed |
description | PURPOSE: The aim of this study is to investigate the efficacy and safety of needling-revision augmented with a high dose of mitomycin C (MMC) in failing or failed blebs after trabeculectomy in Indian eyes. METHODS: Prospective, noncomparative, interventional study. All patients (>18 years) who had raised intraocular pressure (IOP) following trabeculectomy (>6 weeks and <2 years), who had a flat bleb, bleb encapsulation, and/or required antiglaucoma medication (AGM) for IOP control were eligible for inclusion. MMC was injected subconjunctivally at least ½ hour before the needling procedure was carried out at the slit lamp in the outpatient's clinic. RESULTS: Thirty-nine eyes of 38 patients were included. The median follow-up was 20 months and time interval between trabeculectomy and needle revision was 113 days. Initially, in all cases, aqueous flow was re-established with a raised bleb; 7 eyes required repeat needling. IOP decreased from median 24 mmHg (Q1 21, Q3 27, interquartile range [IQR] 6, range 18–35) preneedling to median 14 mmHg (Q1 10, Q3 16, IQR 6, range 6–18) postneedling at last follow-up (P < 0.0001, 95% confidence interval [CI]: 8.2–13.0). The use of AGM reduced from median 1 (Q1 0, Q3 3, IQR 3, range 0–4) preneedling to median 0 postneedling (P < 0.0001, 95% CI: 1–2). Complete success was seen in 28 eyes (71.8%, 95% CI: 71.1%–96.4%); another 5 eyes (12.8%) were controlled with AGM (qualified success) with overall success of 84.6%. Most complications were transient in nature with resolution within 1 week. One patient developed hypotony, and another developed a late bleb leak. CONCLUSION: Needling revision augmented with high-dose MMC, at the slit lamp, effectively rescues failing or failed filtration, and appears to be safe. |
format | Online Article Text |
id | pubmed-5778587 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-57785872018-02-02 Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes Pathak-Ray, Vanita Choudhari, Nikhil Indian J Ophthalmol Original Article PURPOSE: The aim of this study is to investigate the efficacy and safety of needling-revision augmented with a high dose of mitomycin C (MMC) in failing or failed blebs after trabeculectomy in Indian eyes. METHODS: Prospective, noncomparative, interventional study. All patients (>18 years) who had raised intraocular pressure (IOP) following trabeculectomy (>6 weeks and <2 years), who had a flat bleb, bleb encapsulation, and/or required antiglaucoma medication (AGM) for IOP control were eligible for inclusion. MMC was injected subconjunctivally at least ½ hour before the needling procedure was carried out at the slit lamp in the outpatient's clinic. RESULTS: Thirty-nine eyes of 38 patients were included. The median follow-up was 20 months and time interval between trabeculectomy and needle revision was 113 days. Initially, in all cases, aqueous flow was re-established with a raised bleb; 7 eyes required repeat needling. IOP decreased from median 24 mmHg (Q1 21, Q3 27, interquartile range [IQR] 6, range 18–35) preneedling to median 14 mmHg (Q1 10, Q3 16, IQR 6, range 6–18) postneedling at last follow-up (P < 0.0001, 95% confidence interval [CI]: 8.2–13.0). The use of AGM reduced from median 1 (Q1 0, Q3 3, IQR 3, range 0–4) preneedling to median 0 postneedling (P < 0.0001, 95% CI: 1–2). Complete success was seen in 28 eyes (71.8%, 95% CI: 71.1%–96.4%); another 5 eyes (12.8%) were controlled with AGM (qualified success) with overall success of 84.6%. Most complications were transient in nature with resolution within 1 week. One patient developed hypotony, and another developed a late bleb leak. CONCLUSION: Needling revision augmented with high-dose MMC, at the slit lamp, effectively rescues failing or failed filtration, and appears to be safe. Medknow Publications & Media Pvt Ltd 2018-01 /pmc/articles/PMC5778587/ /pubmed/29283127 http://dx.doi.org/10.4103/ijo.IJO_523_17 Text en Copyright: © 2017 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Pathak-Ray, Vanita Choudhari, Nikhil Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes |
title | Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes |
title_full | Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes |
title_fullStr | Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes |
title_full_unstemmed | Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes |
title_short | Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes |
title_sort | rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin c in indian eyes |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5778587/ https://www.ncbi.nlm.nih.gov/pubmed/29283127 http://dx.doi.org/10.4103/ijo.IJO_523_17 |
work_keys_str_mv | AT pathakrayvanita rescueoffailingorfailedtrabeculectomyblebswithslitlampneedlingandadjunctivemitomycincinindianeyes AT choudharinikhil rescueoffailingorfailedtrabeculectomyblebswithslitlampneedlingandadjunctivemitomycincinindianeyes |