Cargando…

An automated A-value measurement tool for accurate cochlear duct length estimation

BACKGROUND: There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round win...

Descripción completa

Detalles Bibliográficos
Autores principales: Iyaniwura, John E., Elfarnawany, Mai, Ladak, Hanif M., Agrawal, Sumit K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5778705/
https://www.ncbi.nlm.nih.gov/pubmed/29357924
http://dx.doi.org/10.1186/s40463-018-0253-3
_version_ 1783294407396556800
author Iyaniwura, John E.
Elfarnawany, Mai
Ladak, Hanif M.
Agrawal, Sumit K.
author_facet Iyaniwura, John E.
Elfarnawany, Mai
Ladak, Hanif M.
Agrawal, Sumit K.
author_sort Iyaniwura, John E.
collection PubMed
description BACKGROUND: There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. METHOD: Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. RESULTS: The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p < 0.01 and r = 0.69, p < 0.01, respectively). CONCLUSION: An automated A-value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit cochlear implant recipients in the future.
format Online
Article
Text
id pubmed-5778705
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57787052018-01-31 An automated A-value measurement tool for accurate cochlear duct length estimation Iyaniwura, John E. Elfarnawany, Mai Ladak, Hanif M. Agrawal, Sumit K. J Otolaryngol Head Neck Surg Original Research Article BACKGROUND: There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. METHOD: Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. RESULTS: The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p < 0.01 and r = 0.69, p < 0.01, respectively). CONCLUSION: An automated A-value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit cochlear implant recipients in the future. BioMed Central 2018-01-22 /pmc/articles/PMC5778705/ /pubmed/29357924 http://dx.doi.org/10.1186/s40463-018-0253-3 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Research Article
Iyaniwura, John E.
Elfarnawany, Mai
Ladak, Hanif M.
Agrawal, Sumit K.
An automated A-value measurement tool for accurate cochlear duct length estimation
title An automated A-value measurement tool for accurate cochlear duct length estimation
title_full An automated A-value measurement tool for accurate cochlear duct length estimation
title_fullStr An automated A-value measurement tool for accurate cochlear duct length estimation
title_full_unstemmed An automated A-value measurement tool for accurate cochlear duct length estimation
title_short An automated A-value measurement tool for accurate cochlear duct length estimation
title_sort automated a-value measurement tool for accurate cochlear duct length estimation
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5778705/
https://www.ncbi.nlm.nih.gov/pubmed/29357924
http://dx.doi.org/10.1186/s40463-018-0253-3
work_keys_str_mv AT iyaniwurajohne anautomatedavaluemeasurementtoolforaccuratecochlearductlengthestimation
AT elfarnawanymai anautomatedavaluemeasurementtoolforaccuratecochlearductlengthestimation
AT ladakhanifm anautomatedavaluemeasurementtoolforaccuratecochlearductlengthestimation
AT agrawalsumitk anautomatedavaluemeasurementtoolforaccuratecochlearductlengthestimation
AT iyaniwurajohne automatedavaluemeasurementtoolforaccuratecochlearductlengthestimation
AT elfarnawanymai automatedavaluemeasurementtoolforaccuratecochlearductlengthestimation
AT ladakhanifm automatedavaluemeasurementtoolforaccuratecochlearductlengthestimation
AT agrawalsumitk automatedavaluemeasurementtoolforaccuratecochlearductlengthestimation